Crystal Vision
Control and Status monitoring
Resample
Select to enable resampling of the selected stereo pair
output from the de-embedder. Resampling is used to
seamlessly match the timing of audio signals when the
user-controlled delay is altered and is the default
condition. If resampling is deselected it is essential that
the input and output source is derived from the same
source and the timing should not be adjusted while on
air. Without resampling, an adjustment in timing will
cause a number of audio samples to
be dropped or
repeated. As Dolby E signals cannot be resampled, the
control will be ignored.
Audio gain
Change the gain of the audio inputs by +/- 18dB.
Gain 1-4
(dB)
In total there are 32 audio gain controls, one for each of the 16
channels of de-embedded audio and 16 channels of external audio.
The gain controls will give
±
18dB of gain relative to the input level
up to the point where digital clipping will occur.
Select
channels
Select the group of channels to control. The
options available will depend on the option
sub-boards fitted. The screen grab shown
here is for a single DIOP4 piggyback fitted in
the front position offering eight AES inputs.
Default
Audio
Gain
Select to return all channels to the default gain level.
SYNNER-VF User Manual R1.1
28