Crystal Vision
Specification
Rear Module I/O
RM41
RM57
RM67
One video input and four video outputs, 75 ohm BNC.
One video input and three video outputs, 75 ohm BNC. Optical SC
input/output.
As RM41, but relay bypass switch auto connects video IP to OP3 in the
event of power failure.
Status monitoring
LEDs Front of card edge LED indicators to indicate:
PSU rails present,
SDI input HD/SD,
GPI Out 5 active,
GPI Out 6 active.
GPI inputs
Number and type: 4 x GPI inputs. Recall of 16 presets.
Active pull to ground, pulled up to +5V through 7 kohm.
GPI outputs
Number and type: 2 x GPI outputs, assignable to any of alarm conditions: video input
missing, black or frozen.
Electrically: Open collector transistors 30V, 270 ohm current limit
resistors. Pulled up to +5V through 7 kohm.
Input fail output
Type: Black, Blue, Bars, Last Frame or No Output as selected.
Control
Local: Intuitive board edge interface with two select buttons, shaft encoder and
ten character alphanumeric display.
Remote: RS422/485.
19200 baud, 8 bits, 1 stop no parity.
Control from frame active front panel and remote panel.
VisionWeb Control is available via the web server on the frame and
allows operation using a standard web browser on a PC or tablet.
SNMP control and monitoring via frame CPU and Ethernet connection.
SNMP traps can be set on the following alarms: input missing, video
black, video frozen and input audio missing.
ViViD 3GT-20 User Manual R1.1
33