Crystal Vision
Hardware installation
SW221 3G User Manual R1.4
5
01/09/2016
2.2 Rear modules and signal I/O
The 4U Indigo 4 frame will house up to 24 single height modules with up to three power
supplies. The 2U Indigo 2 frames will house up to 12 single height modules and dual power
supplies. The 1U Indigo 1 frames will house six single height modules and a single power
supply. The Indigo DT desktop box has a built-in power supply and will house up to two
single height modules.
Note:
For details of fitting rear connectors please refer to the appropriate frame manual
Rear module connections with RM53
RM53 fits in all frames
Description
RM53
•
24 SW221 3G modules per
Indigo 4 frame
•
12 per Indigo 2 frame
•
Six per Indigo 1 frame
•
Two per Indigo DT
•
All frame slots can be used
Rear module connections with RM54
RM54 fits in all frames
Description
RM54
•
24 SW221 3G modules per
Indigo 4 frame
•
12 per Indigo 2 frame
•
Six per Indigo 1 frame
•
Two per Indigo DT
•
All frame slots can be used
RM53 BNC
RM54 BNC
I/O assignment
HD/SD IN 2
HD/SD IN 2
Serial Digital Input 2 (Aux or Standby Input)
HD/SD IN 1
HD/SD IN 1
Serial Digital Input 1 (Main Programme Input)
HD/SD OUT 1A
HD/SD OUT 1
(switched)
Reclocked SDI output (Programme Out) with relay
bypass protection (RM54 only)
HD/SD OUT 1B
HD/SD OUT 1
(Unswitched)
Reclocked SDI output (Programme Out) with no relay
bypass protection
HD/SD OUT 2A
HD/SD OUT 2
Reclocked SDI output (User selectable)
HD/SD OUT 2B
NC
No user connection