Crystal Vision
Hardware installation
AVDELAY 3G User Manual R1.11
8
09/08/2016
Potentiometers
These potentiometers have been factory set and should not require further adjustment.
Potentiometer
Function
P1
3.3V rail adjustment
P2
Clock free-running frequency
2.2 Rear modules and signal I/O
The 4U Indigo 4 frame will house up to 24 single height modules with up to four power
supplies. The 2U Indigo 2 frame will house up to 12 single height modules and dual power
supplies. The 1U Indigo 1 frame will house six single height modules and a single or dual
power supply. The Indigo DT desk top boxes have a built-in power supply and will house up
to two single height modules. All modules can be plugged in and removed while the frame is
powered without damage.
Note:
For details of fitting rear connectors please refer to the appropriate frame manual.
Rear module connections with RM62
The RM62 is a single height module used for video only applications.
RM62 rear module connector
Description
RM62
•
24 AVDELAY 3G modules
per Indigo 4 frame
•
12 per Indigo 2 frame
•
Six per Indigo 1 frame
•
2 per Indigo DT
•
All frame slots can be used
BNC
I/O assignment
OPTICAL I/O
SC optical connector. Input or output depending on optical module fitted.
SDI OUT(B)
3G/High Definition/Standard Definition serial digital output
SDI OUT(A)
3G/High Definition/Standard Definition serial digital output
NC
No user connection
NC
No user connection
SDI IN
3G/High Definition/Standard Definition serial digital input