Signal status
The Input Present indicator will illuminate green when a valid input is present or red if the
input is missing.
The video standard is automatically detected and is shown by a yellow indicator.
The audio group for monitoring is selected from this pane by checking the appropriate
radio button. Indication is also given of the channel status within that group.
Further status information is provided by the Statesman logging and alarms feature, which
is described in more detail in the Statesman manual.
Factory Default and Reset
Pressing the Factory Default button will return all parameters to their default values. Any
user configurations saved as presets will be retained.
Factory Reset will also return all parameters to their default value but will also erase all
stored presets.
Parameter
Default value
Gains and levels
0 or 100% as applicable.
Delays
30 seconds
Component Output
RGB
Test pattern
Off
VBI
Blanked
NTSC Setup
Not applied
Audio Group
Group 1
Audio Routing
Ch1>Ch1, Ch2>Ch2, Ch3>Ch3, Ch4>Ch4
Audio channels
Not muted
Headphone output
Output 1-2
Alarms
All masked