background image

Crystal Vision 

 

Hardware installation 

DDA108A-BP User Manual R1.0 

8

 

 

  25/02/10 

 

 

‘a’ pin  

‘b’ pin 

‘c’ pin 

‘d’ pin 

‘e’ pin 

‘f’ pin  

Lo

wer 

8 (5) 

9 (5) 

18 (5) 

26 (5) 

19 (6) 

20 (6) 

7 (5) 

16 (5) 

17 (5) 

25 (5) 

10 (6) 

11 (6) 

8 (7) 

9 (7) 

18 (7) 

26 (7) 

19 (8) 

20 (8) 

7 (7) 

16 (7) 

17 (7) 

25 (7) 

10 (8) 

11 (8) 

5 (5) 

6 (5) 

15 (5) 

24 (5) 

1 (6) 

2 (6) 

4 (5) 

14 (5) 

13 (5) 

23 (5) 

3 (6) 

4 (6) 

5 (7) 

6 (7) 

15 (7) 

24 (7) 

1 (8) 

2 (8) 

4 (7) 

14 (7) 

13 (7) 

23 (7) 

3 (8) 

4 (8) 

3 (5) 

12 (5) 

22 (5) 

21 (5) 

12 (6) 

13 (6) 

10 

10 (5) 

11 (5) 

19 (5) 

20 (5) 

21 (6) 

22 (6) 

11 

3 (7) 

12 (7) 

22 (7) 

21 (7) 

12 (8) 

13 (8) 

12 

10 (7) 

11 (7) 

19 (7) 

20 (7) 

21 (8) 

22 (8) 

Table shows pin number (Remote number) 

Note: 

Remote 1, Remote 3, Remote 5 and Remote 7 are 26 way high-density D-Type female 
sockets. Frame ground is pin 2 and +5V @500mA is pin 1 in each case.  
Remote 2, Remote 4, Remote 6 and Remote 8 are 26 way high-density D-Type male 
plugs and frame ground is pin 6 in each case and +5V @500mA is pin 15 on Remote 2 
and Remote 6.  
The +5V is protected by self-resetting thermal fuses, which limit the total output current 
available from Remotes 1-4 to approximately 1A. Remotes 5-8 are similarly protected.  

2U frame GPI Connections 

GPI lines ‘a’ to ‘f’ of each card connect to two of four rear remote connectors as follows: 

Slot no. 

‘a’ pin  

‘b’ pin 

‘c’ pin 

‘d’ pin 

‘e’ pin 

‘f’ pin  

8 (1) 

9 (1) 

18 (1) 

26 (1) 

19 (2) 

20 (2) 

7 (1) 

16 (1) 

17 (1) 

25 (1) 

10 (2) 

11 (2) 

8 (3) 

9 (3) 

18 (3) 

26 (3) 

19 (4) 

20 (4) 

7 (3) 

16 (3) 

17 (3) 

25 (3) 

10 (4) 

11 (4) 

5 (1) 

6 (1) 

15 (1) 

24 (1) 

1 (2) 

2 (2) 

4 (1) 

14 (1) 

13 (1) 

23 (1) 

3 (2) 

4 (2) 

5 (3) 

6 (3) 

15 (3) 

24 (3) 

1 (4) 

2 (4) 

4 (3) 

14 (3) 

13 (3) 

23 (3) 

3 (4) 

4 (4) 

3 (1) 

12 (1) 

22 (1) 

21 (1) 

12 (2) 

13 (2) 

10 

10 (1) 

11 (1) 

19 (1) 

20 (1) 

21 (2) 

22 (2) 

11 

3 (3) 

12 (3) 

22 (3) 

21 (3) 

12 (4) 

13 (4) 

12 

10 (3) 

11 (3) 

19 (3) 

20 (3) 

21 (4) 

22 (4) 

Table shows pin number (Remote number) 

 

Note: 

Remote 1 and Remote 3 are 26 way high-density D-Type female sockets. Frame ground 
is pin 2 and +5V @500mA is pin 1 in each case.  
Remote 2 and Remote 4 are 26 way high-density D-Type male plugs and frame ground is 
pin 6 in each case and +5V @500mA is pin 15 on Remote 2.  
The +5V output is protected by self-resetting thermal fuses, which limit the total output 
current available from Remotes 1-4 to approximately 1A.  

 

Содержание DDA108A-BP

Страница 1: ...hnology Park Station Road East Whittlesford Cambridge CB22 4WL England E mail sales crystalvision tv Website www crystalvision tv Tel 44 0 1223 497049 Fax 44 0 1223 497059 DDA108A BP SDI distribution...

Страница 2: ...rear connectors 4 Rear module connections with RM01 4 Rear module connections with RM38 5 Rear module connections with RM18 5 Rear module connections with RM02 6 3 2 General purpose interface 7 4U fr...

Страница 3: ...ution amplifier The DDA108A BP may be used with the RM01 single slot rear connector the RM02 quadruple slot rear connector and the RM18 double slot rear connector If relay bypass is required the rear...

Страница 4: ...des power rail monitoring and signal status DDA108A BP front edge view LED Location colour Meaning when lit INPUT Green Valid DVB ASI SDI input detected PSU Green Power supply voltage present Cable eq...

Страница 5: ...l house up to 2 modules with a single height rear connector The 4U 2U and 1U frames have a hinged front panel which gives access to the PSU and all modules The desk top box has a removable front The u...

Страница 6: ...put D DVB ASI SDI Output E DVB ASI SDI Output F DVB ASI SDI Output Rear module connections with RM18 RM18 fits in all frames Description RM18 12 modules in 4U 6 in 2U 3 in 1U 1 in a desk top box 1 mod...

Страница 7: ...dules per rear connector 9 connections available Card 1 fits in slots 1 5 and 9 Card 2 fits in slots 2 6 and 10 Card 3 fits in slots 4 8 and 12 No card fits in 3 7 or 11 BNC I O assignment SDI IN DVB...

Страница 8: ...put Present Input Absent b Not assigned Not assigned c Not assigned Not assigned d Not assigned Not assigned e Not assigned Not assigned f Not assigned Not assigned The following tables show the GPI p...

Страница 9: ...which limit the total output current available from Remotes 1 4 to approximately 1A Remotes 5 8 are similarly protected 2U frame GPI Connections GPI lines a to f of each card connect to two of four re...

Страница 10: ...s and frame ground is pin 6 and 5V 500mA is pin 15 The 5V output is protected by self resetting thermal fuses which limit the total output current available from Remotes 1 2 to approximately 1A Indigo...

Страница 11: ...valid video input is present and that any cabling is intact The video output is low quality Check that the maximum length has not been exceeded The card no longer responds to card edge control Check t...

Страница 12: ...Power consumption 2 5 W Inputs Video 270Mb s serial digital to EBU Tech 3267 E and SMPTE 259M Cable equalisation 250m Belden 8281 or equivalent Outputs Number and type 8 non re clocked Each will drive...

Отзывы: