REMOVE IGNITOR LEAD FROM PILOT ASSEMBLY
UNDO SCREWS SECURING OXY PILOT TO FIRE TRAY
RE-ASSEMBLE IN REVERSE ORDER
TURN ON GAS SUPPLY,CHECK FOR SOUNDNESS AND RECOMMISION APPLIANCE
4.2 Cleaning
Before cleaning any part of the appliance ensure the gas is turned off and the fire is not hot
Remove trims from appliance before cleaning by pulling it free from magnets
Brass/chrome trim can be cleaned with brasso or other brass cleaner
Colored finishes need wiping with a damp cloth
Coals and ceramics : if for any reason it is necessary to remove coals or ceramics then before
replacement the burner should be checked that no particles have deposited on to the burner and if
necessary remove and refer to instructions to replace
Ceramics should be cleaned by shaking any debris from them under no circumstances brush them or
vacuum as this can be detrimental to them
4.3 installer spare parts
Fuel bed cf2 01 oxypilot manual cf208
Front fibre cf2 02 oxypilot mertik cf209
Trim cf2 03(state color) oxypilot bray cf210
Gas valve cf204 (manual)
Gas valve mertik cf205(mertik)
Gas valve bray cf206(bray)
Main matrix cf207
Other parts are available on request
4.4
trouble
shooting pilot
problems
Issue 1
!
15
Troubleshooting pilot light
Left above a correct blue flame right above a incorrect yellow flame
With a strong flame not small aeration hole needs cleaning
It is important the pilot flame stays strong and blue as on the left as it
creates good cross lighting and no build up of gas then ignition which can
be dangerous