background image

 

 

1 valentine’s buildings 

Bechers drive 

Aintree racecourse Business Park 

L9 5ay 

CF1 L GAS APPLIANCE 

THE CONNELLY COLLECTON  

 

INSET CONVENTIONAL FLUED GAS FIRE 

 

INSTALLATION & USERS INSTRUCTIONS 

 

FOR USE WITH NATURAL GAS 

G20 @ 20 mbar 

For use in GB and IE 

 

 

 
 
 
 
 
 

THESE INSTRUCTIONS MUST BE LEFT WITH THE USER FOR FUTURE REFERENCE 

 
 
 
 
 
 
 

Содержание CF1 L

Страница 1: ...e Business Park L9 5ay CF1 L GAS APPLIANCE THE CONNELLY COLLECTON INSET CONVENTIONAL FLUED GAS FIRE INSTALLATION USERS INSTRUCTIONS FOR USE WITH NATURAL GAS G20 20 mbar For use in GB and IE THESE INST...

Страница 2: ...N REQUIREMENTS PAGE 1 0 IMPORTANT NOTES 3 2 0 INSTALLATION REQUIREMENTS 4 3 0 APPLIANCE INFORMATION 5 4 0 FLUES AND BUILDERS OPENING REQUIREMENTS 7 5 0 FIREPLACE OPENING SIZES AND CATCHMENT SPACE 8 6...

Страница 3: ...e used for the protection of young children the elderly the infirm and pets 1 5 DO NOT burns paper or rubbish in the fire 1 6 It is important for the safe operation and to maintain efficiency that the...

Страница 4: ...tal Manufacture parts This fire must not be installed in a room that contains a bath or shower This fire cannot be installed onto a combustible wall All combustible materials must be removed from the...

Страница 5: ...NPUT 2 9kW 2 9kW 4 1kW 2 9kW COLD PRESSURE 20 1mbar 20 1mbar 20 1mbar 20 1mbar IGNITION AUTOMATIC AUTOMATIC AUTOMATIC AUTOMATIC SPARK GAP 4mm 4mm 4mm 4mm PACKED WEIGHT KG KG KG KG GAS CONNECTION 8mm 8...

Страница 6: ...6 Tall version Wide version ALL MODELS HAVE A 25mm AIR SUPPLY AT THE FRONT BOTTOM UNDER NO CIRCUMSTANCES SHOULD THIS BE BLOCKED OFF AT ANY TIME...

Страница 7: ...E TEST BOTH TESTS ARE A SEPARATE PROCEDURE 4 2 Purpose Made Builders Opening With a Conventional Stone Flue With a minimum cross sectional dimension of 175mm 7 and minimum effective height of 3 meters...

Страница 8: ...th to accommodate any debris which may fall from the chimney this depth must be sufficient to accommodate 12 litres of volumetric space in a conventional brick built chimney 5 3 This appliance is not...

Страница 9: ...ed into the underneath of the appliance will then have to be finished with the appliance in place see diagram below 6 2 It is important when installing the convector box that all gaps around the insid...

Страница 10: ...n and remove the fire tray The gas pipe entry plate can be opened and the gas pipe installed ready for the box to be positioned Position the box ensuring the gas pipe is bent into the box soldered joi...

Страница 11: ...the burner fill the burner with the mica fil and turn on the appliance to the full on position and check the gas pressure is 20 mbars 1 mbar Once 20 mbars is verified remove the manometer and replace...

Страница 12: ...OUNDED BY THE CHIPPING S EVENLY SPREAD THREE REAR LOGS SIT AS LEFT TWO FRONT LOGS SIT AS LEFT TOP LEFT LOG SITS ACROSS BUT DOES NOT IMPINGE THE FLAMES WHEN APPLIANCE IS TURNED ON CENTRE LOG SITS ON RE...

Страница 13: ...URNER WITH MICA FILL THE BURNER IS SURROUNDED BY THE CHIPPING S EVENLY SPREAD THREE REAR LOGS SIT AS LEFT THREE FRONT LOGS SIT AS LEFT FINAL 5 LOGS SIT ACROSS RAISED OFF BURNER THEY ARE POSITIONED THR...

Страница 14: ...out Small fill the burner tray with the brown mica fil around the burner tray the granules sit evenly spread The 2 rear logs sit as shown The 2 front logs sit as shown The 3 logs sit across the burner...

Страница 15: ...he fire can now be turned on and a spillage test performed If spillage persists the flue is not functioning correctly and a fault exists If after investigation the fault cannot be traced and rectified...

Страница 16: ...te Slide the slide switch to the right to the On position I symbol To start the fire press the power button and hold for 1 second then release The burner will within around 1 to 10 seconds adjust to t...

Страница 17: ...s of the button area control The green unlock light will illuminate Keep the handset held to keep the control unlocked to enable operation of the buttons Then with the other hand touch and hold a fing...

Страница 18: ...control held to keep the green light on and therefore handset safety feature unlocked The H indicates that it is time to set the timer to either 24 hour display or 12 Hour AM or PM display Press the...

Страница 19: ...times until the time of day is displayed on the handset The control is now ready for use with the Fire Control Note the legend at the bottom shows the battery condition of both the batteries in the h...

Страница 20: ...features Do not do a long press and hold above but a normal short press and release will take you into the advanced settings area Advanced settings options are Back light o A Automatic default settin...

Страница 21: ...ously and press the mode button as many times as necessary until the word MAN and the Zzz symbols are flashing at the top of the display Press and release the set button and this will put the control...

Страница 22: ...enter this mode Press the set button again to see the temperature setting that is set and the mode the default is 24 C and on the left of the display is a sun symbol showing it s the day temperature...

Страница 23: ...lected and adjusted if necessary by pressing set then mode while in thermostat mode Pressing mode button toggles through from day to frost modes The purpose of these settings is to help your fire to a...

Страница 24: ...next time of 09 00 press and release SET change the flashing sun symbol to a flashing moon symbol by pressing and releasing the and buttons then press and release SET again to store the moon setting 1...

Страница 25: ...liary device sometimes not used depending upon you fire model Starting the fire Pickup and keep hold of the handset as described above to unlock the keypad Press and hold the power button continuously...

Страница 26: ...d releasing the button will move the burner one step at a time Pressing the button continuously will move the burner rate to the maximum full when pressing or minimum burner power if pressing Stopping...

Страница 27: ...ton is pressed for too long or too short a time this is taken as an accidental press and the fire will not ignite for extra safety reasons It is to try an ensure that the starting operation of the fir...

Страница 28: ...cess to the Inside for cleaning Advise the customer that the fire must never be used with the Door Open or if the Glass Panel is found to be cracked Chipped or damaged Hand all the Instructions to the...

Страница 29: ...n both the outside and inside with a damp cloth allowed to dry then wiped with a Dry cloth to remove smears To do this Remove the 2 screws at the top and bottom Left and top and bottom right Hand side...

Страница 30: ...around the top tray where any debris or dust has been left by the stone chippings The top burner cover can now be removed by unscrewing the 6 screws holding it in place With the top burner cover remov...

Страница 31: ...H DISPLAY CONNELLY 01 HANDSET WITHOUT DISPLAY CONNELLY02 ODS CONNELLY03 INJECTOR 500 CONNELLY04 STONE CHIPPINGS CONNELLY05 LOGSET STATE MODEL CONNELLY06 GLASS PANEL AND SEAL STATE MODEL CONNELLY07 TES...

Отзывы: