CP-JR-CT1SW Cleaning and Maintenance 

Recommendations

Crysalli Beverage Systems

 

a division of WPD

 

1739 Sabre Street, Hayward, CA 94545

www.crysalli.com

510.732.0100

Daily:

 

☐ Wipe down the unit or draft tower, cleaning and 

drying all surfaces. (Use window cleaner on 

mirrored and chrome finishes). 

 

☐ Clean and dry drain pan and drain grate. Check 

that water is draining, pour warm water down 

drain if necessary.

 

☐ Check over faucets for action and hand tighten 

any loosened handles or nuts on them. A 

wobling faucet indicates the faucet body is 

loosening from the shank which can result in 

a leak, faucet coming off or stripping the teeth. 

Use a shank wrench to tighten the shank nut to 

the faucet.

 

☐ Check flow from faucet, loosen, readjust, and 

tighten flow control knob as needed.

 

☐ Check that flow and temperature of water 

poured from the unit are consistent to average 

use. 

Weekly:

 

☐ Clean the faucets by wiping them down. If there 

is any scale or slime submerge them in cleaners/

sanitizer and use a brush on them. 

Monthly:

 

☐ Visually check condenser coil for dust and blow 

out with compressed air.

 

☐ Check for good water pressure at the water filter 

system by running water from flush valve on 

filter.

 

☐ Visually check pre-filter in clear bowl on water 

filter system (if applicable) to determine if it 

needs replacing. Use only EPC5-10 replacement 

pre-filter cartridge.  

Quarterly:

 

☐ Check the water bath level, either top off or 

drain, clean and refill.

Semianually:

 

☐ Change the water filters. Use only 2FC 

replacement filter cartridges. 

 

☐ Drain water bath, clean and refill with new water 

(pull white stand pipe inside water bath to drain 

water. Be sure have a container under the ss 

drain spout at the front of the unit to catch the 

draining bath water). 

 

☐ Remove and disassemble faucets for cleaning 

and inspection.

Annually:

 

☐ Inspect internal water bath components such as 

agitator pump and all hose connections.  

 

☐ Flush and rinse system with food safe sanitizer 

(this work should be performed by a certified 

service tech). 

Содержание CP-JR-CT1SW

Страница 1: ...nstall Guide CP JR CT1SW CP JR CT1SW and CP JR CT1SW PB Crysalli Beverage Systemsa division of WPD 1739 Sabre Street Hayward CA 94545 www crysalli com 510 732 0100 06022022 Register your product onlin...

Страница 2: ...24 mpt PASVPP6 Angle stop TEE in adaptor For adding an outlet off the anglestop 10 JG 3 8 Locking Clips PIC1812R Collet locking clip for 3 8 Hose to JG fittings 1 12 of 3 8 OD hose PE 12 EI 25 Water...

Страница 3: ...the submerged Agitator Pump S0833 The Ice Bank Control sensor and Agitator in your Crysalli unit are connected to and are energized by the Liquid Level Control Board LLCB part S0068 U This is the comm...

Страница 4: ...om the system and flush filter 12 For push button PB models flow rate can be adjusted via the pin on the valve Remove lid to access Use a small flat head screw driver adjust Right turns slows restrict...

Страница 5: ...ww crysalli com 510 732 0100 Drain hose to floor drain Condensation will build inside unit must drain or unit will overflow Water line connection to filter 3 8 SS Hose Barb Remove lid fill water bath...

Страница 6: ...ube firmly in place without deforming it or restricting flow How to make a Standard Connection CUT THE TUBE SQUARE Cut the tube square and remove burrs and sharp edges Ensure that the outside diameter...

Страница 7: ...k for leaks For a dedicated angle stop water valve use the PSEI6012U9 adaptor fitting To use the PSEI6012U9 angle stop adaptor identify the angle stop water valve in your cabinet that will be the wate...

Страница 8: ...een the filter system and chiller 4 Turn on water and check for leaks at your connection points Operation 1 Reset to work a Keep pressing button for 4 seconds the control unit activates solenoid valve...

Страница 9: ...s it to adjust flow rate The faucet handle is self closing when released The internal spring creates this tension to close the valve and shut off flow The spring can be removed if self closing is not...

Страница 10: ...steps you took it apart in The armature needs to be snug but do not over tighten Over tightening it can result in pining the piston down to the point water will not flow 10 Before putting the solenoi...

Страница 11: ...ekly Clean the faucets by wiping them down If there is any scale or slime submerge them in cleaners sanitizer and use a brush on them Monthly Visually check condenser coil for dust and blow out with c...

Страница 12: ...or the Product Additional expenses including without limitation service travel time overtime or premium labor charges accessing or removing the Product or shipping are the responsibility of the consum...

Отзывы: