Model Number:
Install Date:
Serial Number:
Installer/Servicer:
CP-JR-CT1SW Cleaning and Maintenance
Recommendations
Crysalli Beverage Systems
a division of WPD
1739 Sabre Street, Hayward, CA 94545
www.crysalli.com
510.732.0100
Daily:
☐ Wipe down the unit or draft tower, cleaning and
drying all surfaces. (Use window cleaner on
mirrored and chrome finishes).
☐ Clean and dry drain pan and drain grate. Check
that water is draining, pour warm water down
drain if necessary.
☐ Check over faucets for action and hand tighten
any loosened handles or nuts on them. A
wobling faucet indicates the faucet body is
loosening from the shank which can result in
a leak, faucet coming off or stripping the teeth.
Use a shank wrench to tighten the shank nut to
the faucet.
☐ Check flow from faucet, loosen, readjust, and
tighten flow control knob as needed.
☐ Check that flow and temperature of water
poured from the unit are consistent to average
use.
Weekly:
☐ Clean the faucets by wiping them down. If there
is any scale or slime submerge them in cleaners/
sanitizer and use a brush on them.
Monthly:
☐ Visually check condenser coil for dust and blow
out with compressed air.
☐ Check for good water pressure at the water filter
system by running water from flush valve on
filter.
☐ Visually check pre-filter in clear bowl on water
filter system (if applicable) to determine if it
needs replacing. Use only EPC5-10 replacement
pre-filter cartridge.
Quarterly:
☐ Check the water bath level, either top off or
drain, clean and refill.
Semianually:
☐ Change the water filters. Use only 2FC
replacement filter cartridges.
☐ Drain water bath, clean and refill with new water
(pull white stand pipe inside water bath to drain
water. Be sure have a container under the ss
drain spout at the front of the unit to catch the
draining bath water).
☐ Remove and disassemble faucets for cleaning
and inspection.
Annually:
☐ Inspect internal water bath components such as
agitator pump and all hose connections.
☐ Flush and rinse system with food safe sanitizer
(this work should be performed by a certified
service tech).