UK DX260 Smokemeter 

EQUIPMENT MANUAL 

 
 
 
 
 

I323805 Issue 1 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Crypton - a Brand of the Continental Corporation 

Содержание DX260

Страница 1: ...UK DX260 Smokemeter EQUIPMENT MANUAL I323805 Issue 1 Crypton a Brand of the Continental Corporation...

Страница 2: ...only 10 Maintenance 11 Oil Temperature Probe 15 Adapters 15 Connection 15 Operation 15 Engine Tachometers 16 Connection 17 Battery CDSS6 DX211 12 17 Consumables 18 Technical Specifications 20 After S...

Страница 3: ...eration particularly mains supply and fault codes self test if applicable Software Licence Further to our general Terms Conditions of Sale the software described in these Operating Instructions is fur...

Страница 4: ...ystem of a hot engine beware of the fire hazard caused by fuel spilling onto manifolds ignition distributor etc 8 Position the mains cable and sample pipe in such a manner that they do not present a h...

Страница 5: ...d The Smokehead should be returned to base when not being used DX260 1xxBT SMOKEHEAD Wireless The DX260 1BT wireless Smokehead uses wireless technology to communicate directly with the host computer T...

Страница 6: ...of use alternative pipes are available DX210 4A Sampling pipe DX210 6 Sampling pipe DX210 6 is used for vertical exhausts Hang the sampling pipe and the sampling head as shown in the illustration For...

Страница 7: ...ase to the O ring to assist fitment of the sampling pipe to the sampling head The results of free acceleration testing will be affected by changes in sampling pipe diameter and or length Only genuine...

Страница 8: ...utilised When the equipment is first switched on the smokehead should be firmly positioned onto its charging cradle and the unit should be allowed to charge for a minimum of five to six hours or prefe...

Страница 9: ...rging rate is reduced to Trickle Charge When charging for a protracted period for example overnight a trickle charge of 15 hours will completely recharge the internal battery A blue LED on the Handle...

Страница 10: ...LLUMINATED Return the Smokehead to Charging Cradle LED should display according to Charging level required LED NOT ILLUMINATED WHEN SMOKEHEAD IS ON CHARGING CRADLE Check that the Smokehead is correctl...

Страница 11: ...ormal circumstances the sampling head does not require cleaning If a sampling pipe becomes restricted with deposits the test results can be affected To clean a sampling pipe remove the sample probe fr...

Страница 12: ...ly pull out the lens housing and wipe the lens with a soft cloth if required a little methylated spirit will assist cleaning 4 Refit the lens housing with the arrow pointing upwards a little silicon g...

Страница 13: ...the metal cable clamp from the end plate Loosen the cable gland strain relief and remove the cable from the end plate 6 Re fit the new cable through the cable gland strain relief and secure to the end...

Страница 14: ...on Discard the two securing screws earlier versions or the plastic spacer later versions no longer required 7 Re connect the 2 pin plug 4a the 2 pin plug 4b and the 3 pin plug 5 8 Relocate the end pla...

Страница 15: ...be charging at all times whilst stored in the holster indicated by the status indication light on the probe adapter glowing red Temperature probes There are two flexible temperature probes either of...

Страница 16: ...X211 12BT The CDSS6BT RPM Tacho is identical to the CDSS6 except that it provides a signal to the host PC via a wireless connection It will only work with wireless enabled equipment and does not use t...

Страница 17: ...h on vehicle lights and allow to idle The unit will search for a steady speed each time it is powered up if the engine speed falls or the engine type is changed This is the initialisation period and m...

Страница 18: ...261 2m Standard for CDSS6 Cable Smokehead Cable Assembly DAS00497 10m StandardA2C89476700 DX260 1BT 01 Battery Pack For use with DX260 1BT Head only A2C88489000 DX230 130 16 Fan Kit Replacement fan fo...

Страница 19: ...19 Consumables Temperature Probe Adapters use with DX210 25A and DX210 26 probes DX211 11 DX211 11BT 5m cabled Adapter A2C88694100 Wireless Probe Adapter A2C89185500...

Страница 20: ...Technical Specification 20...

Страница 21: ...Technical Specification 21...

Страница 22: ...Technical Specification 22...

Страница 23: ...ded by the agent from whom your equipment was purchased Disposal of equipment Do not dispose of this equipment as miscellaneous solid municipal waste but arrange to have it collected separately The re...

Страница 24: ...grated product that can be purchased as either a complete test lane or as separate components making it an ideal choice whether up grading for One Man testing or a completely new Automated Test Lane A...