CRT1081IRD-S2-MX
USER’s MANUAL
3.2
Hardware Installation
The following sequence of operations is recommended.
1. Unpack the device and check that all components are safe. If the device was taken to the installation
room from a colder place wait at least one hour until condensed damp is dry.
2. Put the device at the place of operation and fix it properly. Special telecom rack is the best choice
for multiple devices installation.
3. Provide necessary connections of LNB inputs, ASI inputs and outputs.
4. Connect the device Ethernet port to the same type port of the host PC with cross cord or use patch
cord when Ethernet switch is used.
5.
Connect the power supply cord to an AC outlet. Only specified voltage should be used. Pay a special
attention to use power cords and plugs with a ground wire. The chassis is grounded through the three
prong AC receptacle.
6. Insert CAM Modules into Common Interface slots. To prevent damage of the interface only use
EN50221 specified CAM Modules, push them gently no exceeding effort is required.
7. Switch the device power on. Short period LED lights signal the device is ready to operate.
Crypton, January 2013
8