13
Malfunction:
no function, no power LED
Reason:
Remedy:
1. The power supply connection of the device is not correct
Recheck
2. The cabels have no mechanical or electrical contact
Recheck
3. The remote turn-on connection from the head unit to the device is not correct
Recheck
4. Defective Fuses. In case of replacing the fuses, ensure the correct fuse rating
Replace Fuses
Malfunction:
no signal on loudspeakers, but power LED lights up
Reason:
Remedy:
1. The connections of the speakers or the RCA audio cables are not correct
Recheck
2. The speaker cables or the RCA audio cables are defective
Replace cables
3. No signal from the head unit
Check head unit settings
Malfunction:
distortions on the loudspeaker
Reason:
Remedy:
1. The loudspeaker is overloaded
Turn down the level
Turn
down
the
level
on
the
headunit
Switch
off
loudness
on
the
headunit
Reset
bass
EQ
on
the
headunit
Malfunction:
No bass
Reason:
Remedy:
1. Interchange of loudspeaker cable on the high level inputs polarity
Check polarity, reconnect
2. The RCA audio cables are loose or defective
Reconnect or replace the cables