background image

©  2017 CrucialTrak Inc. All right reserved. 

Page | 1

7

 

2.3.  BACS

™ 

Reader: Multi-Biometric Access Control Reader

 

2.3.1. 

Product  Design:  This  access  control  reader  should  be  able  to  read  and 

recognize user's fingerprint / face / iris / vein, RF card information safely. 

(1)

This access control reader should operate one or more biometric modules.

(2)

This

 

access  control  reader  should  be compatible  with  various

card

 

technologies.

2.3.2. 

Security:  This  access  control  reader  should  apply  the  following  enhanced 

security technologies. 
(1) This access control reader should be able to read data appropriately when

using a non-contact method or using the card. The way to read data safely
means:
(a) Data Media Binding Check
(b) Data validation check
(c) Data accuracy

(2) Security  information: Only the person authorized by the  administrator  can

enter the administrator's menu of the reader. In  the case of power outage,
even if the Server PC is unused, the database must be stored in the reader
as well as the database of the PC where the CRUAMS software is installed.
When  the  Server  PC  is  operating,  the  reader  sends  an  event  log  to  the
Server PC to check the event log on the Server PC.
(a) Information download: The terminal should store the access event log,

management event log, and registration information.

(b) Information  upload:  The  terminal  should  be  able  to  upload  access

event  log,  management  event  log,  registration  information,  and
firmware.

(c) Anti-Pass Back: You can set Anti-Pass Back function to use or not use.
(d) User access setting:  It  is necessary  to  be able  to  control the access

time of the user based on the access time set by the administrator.

(e) Fire  detection  (intrusion  detection):  The  administrator  can  set  fire  or

intrusion detection.

2.3.3. 

Product Features 
(1) This access control reader can update firmware using USB and network.
(2) This access control reader shall be universally compatible with most access

control systems in compliance with the SIA AC-01 Wiegand standard.

(3) This  access  control  reader  series  has  biometric  authentication  such  as

fingerprint, face, iris and palm vein so that it can control limited access and
manage workforce more effectively.

(4) This access control reader series should be able to customize by selecting

various options. Customers have the following options:

(5) Video output support (HDMI) option
(6) RF card type support
(7) This access control reader shall be capable of the following audio, and LED

outputs:
(a) LED: The circular recognition LED light source installed  in the  reader

should  be  able  to  indicate  the  state  with  a  different  direction  of  light
rotation according to the authentication process.

(b) Icon  LED:  Displays  the  fingerprint,  face,  iris  and  palm  vein  icon

according to biometric authentication.

(8) This access control reader shall have the following power specification.

(a) Current: 6A

Содержание BACS Quattro

Страница 1: ...BACS Installation User Guide 2017 CrucialTrak Inc All right reserved BACS Quattro Installation User Guide Revision 1 3 June 2017...

Страница 2: ...l other reproductions of this document are prohibited without written permission CrucialTrak makes no warranties expressed or implied with respect to this documentation The information contained herei...

Страница 3: ...raphic errors will be corrected in subsequent editions Ordering Information Please contact your local representative CBCA http www cbcamerica com or visit us on the web at http www crucialtrak com for...

Страница 4: ...System Integration 6 2 Introduction 7 2 1 Overview of BACS Reader 7 2 2 Overview of BACS Reader Network System RS 485 LAN WAN 9 2 3 BACS Reader Multi Biometric Access Control Reader 11 3 Installation...

Страница 5: ...tworking by Using RS 485 Figure 5 Diagram of Networking by Using WAN Figure 6 Terminal Block Pin Map Figure 7 BACSTM Interface Figure 8 BACSTM Power Figure 9 BACSTM TCP IP Connection Figure 10 BACSTM...

Страница 6: ...whether all products and equipment are operating normally before the product arrives at the installation site 1 3 2 The power supply should be checked for proper operation If the power supply needs to...

Страница 7: ...ed tested and loaded on the host computer of the user side 1 5 System Integration 1 5 1 Discuss and work with the user s IT department and administrator before connecting to the network to load on the...

Страница 8: ...for stone plate 6 mm plastic anchor 5 mm x 38 mm drywall screw for wooden or metal plate 5mm x 38 mm drywall screw Lock device requirement dry contact input as open signal power fail auto release In...

Страница 9: ...jor technologies touchless fingerprint palm vein iris and face recognition provides a superior level of security The four different biometric modules capture and authenticate user s biological informa...

Страница 10: ...t X 1 Quick Installation Guide X 1 Preparation Tools Not included in package Grounded AC Power cord AWG 22 or for higher current paired DC power cable AWG 22 or for higher current Power tool for stone...

Страница 11: ...2017 CrucialTrak Inc All right reserved Page 10 Figure 2 Component Diagram of BACSTM Reader...

Страница 12: ...en too strong to leave space for base bracket to rotate After fixing the Mounting bracket align pin of Quattro neck and furrow of base bracket and twist in counter clock wise for locking When unlockin...

Страница 13: ...e are as below 110 cm European 100 cm North America 90 cm Asian After installation please set default Y position default angle y of PAN TILT module in SETUP page See Value SETUP section in this guide...

Страница 14: ...isting access terminals attachable onto any third party controllers It is possible to connect numerous BACS via Ethernet or RS 485 Figure 3 shows a systemic diagram for network configuration Figure 4...

Страница 15: ...device one Quattro must be assigned as Master in system For enrollment connect a mouse a keyboard and a HDMI monitor to Quattro Other Quattros can be slave devices and have to referring toward Master...

Страница 16: ...2017 CrucialTrak Inc All right reserved Page 15 Figure 4 Diagram of Networking by Using RS 485 Figure 5 Diagram of RS 485 connection...

Страница 17: ...2017 CrucialTrak Inc All right reserved Page 16 Figure 6 Diagram of Networking by Using WAN Figure 7 Diagram of LAN Connection...

Страница 18: ...rminal should be able to upload access event log management event log registration information and firmware c Anti Pass Back You can set Anti Pass Back function to use or not use d User access setting...

Страница 19: ...following cable specification conditions a Cable type RS 485 TCP IP 11 This access control reader has two relays for door and alarm control 12 This access control reader should be capable of storing 5...

Страница 20: ...cialTrak Inc All right reserved Page 19 3 Installation 3 1 BACSTM Reader Figure 6 and Figure 7 show the overview of the interface for the installation Figure 6 Terminal Block Pin Map Figure 7 BACSTM I...

Страница 21: ...B ethernet HDMI Keyboard Mouse etc Monitor 30p socket 12V DC Wiegand in out Relay Sensor Exit RS 485 Etc Cat 5e ethernet cable connect with other devices enroll station CRUAMS server other DUO Quattro...

Страница 22: ...gure 8 shows the connection for the power Figure 8 BACSTM Power 3 1 2 TCP IP When using the TCP IP method it is possible to construct the access control system by using this product with LAN method Co...

Страница 23: ...s product is connected to another main controller this product functions only as a card or fingerprint reader not as a controller At this time when you want to hand over the information that this prod...

Страница 24: ...nect the pin 22 24 26 28 of the Terminal block of this product to the RF Card Reader 3 1 6 In addition third party products that use Wiegand communication can be used Figure 12 BACSTM Wiegand in 3 1 7...

Страница 25: ...e and connecting to each output devices Connect electric strike and alarm devices to terminal block to operate Figure 14 shows the configuration for the relay connection Figure 14 BACSTM Relay Connect...

Страница 26: ...ple Refer to lock device wiring instruction that manufacturers provide and follow recommendation Confirm compatibility and max current with lock devices EM LOCK Dead Bolt and Striker Max current of Qu...

Страница 27: ...ccessfully If you are registered on the Enroll machine you can try fingerprint authentication by Verify operation When the fingerprint authentication is successful the following blue fingerprint icon...

Страница 28: ...u can try vein authentication and you will see the blue vein icon when vein authentication is successful See Fig 18 d As an additional option the vein authentication confirmation GUI is also available...

Страница 29: ...k Inc All right reserved Page 28 Ref How to change mode Once Quattro is turned on Enroll mode or Verification mode will be shown as bellow You can change operating mode by clicking Tasks in task bar o...

Страница 30: ...cations BACS Quattro Enroll BACS Manager by clicking x of upper left window then applications will be automatically re executed Choose BACS Manager to add delete list up users and add supplementary te...

Страница 31: ...2017 CrucialTrak Inc All right reserved Page 30 4 2 Verify Process Through Graphical User Interface 4 2 1 Default screen 4 2 2 Front TOF sensor is detected...

Страница 32: ...2017 CrucialTrak Inc All right reserved Page 31 4 2 3 Face authentication is completed 4 2 4 Face Iris authentication is completed...

Страница 33: ...iometric authentications Fingerprint Face Iris Palm Vein are correctly registered ID Name and photo will be appeared on the screen The final authentication success condition can be adjusted from one t...

Страница 34: ...ight reserved Page 33 4 3 How to Use 4 3 1 FACE authentication 4 3 2 IRIS authentication For iris recognition please look at the infra red light and hold for 1 to 3 seconds Iris tracking system will s...

Страница 35: ...Palm Vein and Fingerprint authentication For fingerprint recognition place your fingers directly above the Finger Print Camera then slowly approach to the camera Do not touch and keep distance from th...

Страница 36: ...Inc All right reserved Page 35 90 Align center of your palm with center of square palm vein sensor Perpendicularly place your palm in 35 70mm distance from palm vein sensor You can find best position...

Страница 37: ...address might be same with Server IP Quattro as slave device type IP of Master at Server IP cell Ask IP address information to network administrator prior to set configuration For multi mode with Qua...

Страница 38: ...er high value causes noise increase 2 Shutter adjustment of brightness default 600 brighter and darker high value causes motion blur 3 detectThreshold value for face discovering default 3 too high val...

Страница 39: ...reserved Page 38 Relay operation time value Door opening time Relay operation time value Door opening time Card type of RFID reader which is connected with Wiegand in port Wiegand out high signal leng...

Страница 40: ...ting 12 Cam Sync option 13 Right Cam shutter value 14 Right Cam brightness value 15 Right Cam low bound bright value 16 Right Cam upper bound bright value 17 Left Cam shutter value 18 Left Cam brightn...

Страница 41: ...identification 3 Timeout during 3 times capturing 4 Technical value 5 Technical value 6 Matching level for identification 7 Matching level for enrollment 8 Image Quality level for identification 9 Im...

Страница 42: ...mity sensor Install Quattro in door and if possible in bright area Make sure users face is not to be placed in back light direction Strongly recommend to use Enrollment Station e4 for register contact...

Страница 43: ...2017 CrucialTrak Inc All right reserved Page 42 Appendix Enroll Station e4 Installation User guide Enroll Station e4 R3...

Страница 44: ...c All right reserved Page 43 Connection USB ethernet HDMI Cooling FAN AC 110V 220V Power SW E4 does not support free voltage please confirm 110 220V prior to supply AC power Do block rear cooling FAN...

Страница 45: ...k Inc All right reserved Page 44 Enroll Process GUI 1 Turn on Enroll station enroll screen will be shown as below then click Enrollment button to start 2 Type User Name and RFID no ID will be generate...

Страница 46: ...t reserved Page 45 3 Introduction screen will be appeared click Next button to start enrollment 4 Step 1 Face enrollment Place your face 50 60cm away from the device Click Capture button when ellipse...

Страница 47: ...on or for better image For clear recognition please register at least 5 different angels of your face images Front right left up down under one ID 6 Step 2 Iris enrollment Press Capture button to star...

Страница 48: ...will be appeared in lower left circle Then Click Next to continue For better image or when only one iris is saned adjust your position and click Try Again for re registration 8 Step 3 Fingerprint enr...

Страница 49: ...ight reserved Page 48 9 Slowly approach your fingers over the green lights camera 5 6cm distance rage is recommended The device captures 10 images of your fingers then It will stat counting when the o...

Страница 50: ...age will be appeared in upper right circle Then Click Next to Palm vein enrollment For better images or failed case Click Try Again 11 Step 4 Palm vein enrollment Click Capture to start stretch thumb...

Страница 51: ...palm vein Please enroll twice for better recognition Captured finger image will be appeared in lower right circle Try again if it needed 13 Click Finish to save your biometric templates and finish the...

Страница 52: ...peared Click Master ID of designated user Click ID then Enroll process will automatically go to next step with ID Linkage Make sure user ID is correct Supervisor needs to double check by comparing wit...

Страница 53: ...ll mode and BACS Manager by clicking icons in left task bar 16 In order to return to Desktop please drag down Enroll GUI screen If you closed any BACS applications Enroll BACS Manager by clicking x of...

Страница 54: ...ndang gu Seongnam si Gyeonggi do Korea 13486 T 82 31 8060 3000 F 82 31 8060 3100 For additional offices around the world see www crucialtrak com corporate offices CrucialTrak Customer Support www cruc...