1.3 Warnings and Notices 

Please read the following before beginning installation.

General Care

•  Proper grounding is strongly recommended to prevent 

electrical damage to the unit or other connected 
devices, including the computer host. Avoid all 
dramatic movement, tapping on the unit, and 
vibration.

• 

 Avoid placing the unit close to magnetic devices, high 
voltage devices, or near a heat source. This includes 
any place where the product will be subject to direct 
sunlight. Do NOT allow water to make contact with 
the unit.

• 

Before starting any type of hardware installation, 
please ensure that all power switches have been turned 
off and all power cords have been disconnected to 
prevent personal injury and damage to the hardware.

• 

To avoid overheating, the unit should be operated in a 
well-ventilated area. 

• 

Remove the drives before transporting the unit to 
prevent damage to the drive interfaces.

2 Installation Steps

2.1 Installing Hard Drives
a.  Slide the drive carrier out of the RAX unit.

b.  The carrier’s cover is held in place by a screw on the 

rear of the unit. Remove the screw and then remove 
the cover.

c.  Slide the drive in from the front of the carrier.

d.  Mate the connection on the drive with the connection 

on the drive carrier circuit board.

e.  Flip the drive/carrier assembly over and secure the 

drive in place with the provided screws.

f.  Attach the Temperature Control Cooling Sensor to the 

top of the drive with a piece of tape.

g.  Replace the carrier cover and secure the screw on the 

rear of the carrier.

h.  Slide the carrier into the RAX unit.

2.2 Selecting the Operation Mode for Each Bay
Each  bay  comes  equipped  with  a  switch  on  the  front 

bezel that switches between Read/Write Mode and Write 

Protect Mode. Flip the switch for each bay to choose the 

appropriate operation mode.

NOTE:  This section refers only to 3QJp write protect 

models.

R/W (Read/Write)
RAX 3QJp bays will operate like standard external hard 
drives, performing standard read and write functions. The 
drive bay must be set to R/W mode in order to format the 
hard drive.

WP (Write Protect)

RAX 3QJp bays will protect data already on the hard drive. 
The data on the drive can be read but cannot be altered. 

NOTE:  When changing the mode of operation the 

new setting will not take effect until the power is 

cycled or a drive is removed or added. The mode LED 

will then change to indicate the new mode.

2.3 Host Connections
RAX units connect to your computer in one of four ways; 

USB 3.0, USB 2.0, Firewire 800, or eSATA. Choose one of the 
four cable types to use and plug it into the unit. Each bay 

requires its own data connection.

2.4 Operating Your RAX Unit
a.  Connect the data cables to the RAX unit and to your 

computer.

b. 

Plug  in  the  power  cord  to  the  RAX  unit  and  to  a 

grounded electrical outlet.

c.  If you have not already done so, slide the carriers into 

the open receiving frames on the RAX unit.

d.  Insert the Security Key into the Mini-USB Security Key 

Port on the face of each receiving frame.

e. 

Insert a DataPort key into the key lock and turn it 90 

degrees clockwise to power on the unit.

f. 

When both green LEDs are lit on both receiving frames, 

showing that the drives are ready and encryption is 
activated, remove the Security Key and store it in a safe 
location. 

When any hard drive is first used with a RAX Secure unit, 

it will show up as a blank, unallocated drive and you’ll need 
to format the drive inside the unit before you can use it. 

Note that formatting a drive will erase all data on 
the drive, so be sure to back up your data before 
beginning this operation.

NOTE:   If  any  of  the  drives  are  inaccessible  after 

powering on the unit, try the following steps:

 

1. Turn off the power.

 

2. Remove the drive(s) in question.

 

3. Reinsert the drive(s).

 

4. Turn on the power.

Содержание RAX Secure 3QJ

Страница 1: ...files Optional write protection on the RAX 3QJp enclosure prevents data from being overwritten or altered Removable carriers enclose and protect hard drives when removed from the RAX enclosure eSATA...

Страница 2: ...antity RAX 3QJ or 3QJp Unit 1 Power Cord 1 Key Set 1 Screw Kit 1 Quick Start Guide 1 1 2 Identifying Parts of your RAX Secure Enclosure Power Switch Fan LED Power LED Bay Keylock Drive Activity LED Dr...

Страница 3: ...hoose the appropriate operation mode NOTE This section refers only to 3QJp write protect models R W Read Write RAX 3QJp bays will operate like standard external hard drives performing standard read an...

Страница 4: ...indow that opens left click on Disk Management labeled A in the picture below For Windows 8 1 press WINKEY X then select Disk Management from the menu that pops up b The drive should appear in the lis...

Страница 5: ...cure and level in the rack Circuit Overloading Do not overload the circuits Refer to the name plate ratings on the equipment Reliable Grounding Maintain reliable grounding of rack mounted equipment by...

Страница 6: ...A Yes But for best performance don t daisy chain other Firewire devices to the same cable Q When I change a drive to Write Protect Mode in my RAX 3QJp unit I can still copy a file to the hard drive Is...

Страница 7: ...ee is authorized to make any modification extension or addition to this warranty In no event will CRU or its suppliers be liable for any costs of procurement of substitute products or services lost pr...

Отзывы: