5. Sweat Solder Adapter
6. Cover Tube
7. Wall Escutcheon
8. Supply Stop
9. Installation Instructions
1. Flush Valve Assembly
2. Down Tube and Vacuum Breaker
3. Spud Coupling Nut and Washers
4. Spud Flange
All American Standard Products Are Water Tested At Our Factory.
Some Residual Water May Remain In The Valve During Shipping.
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your
installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
Remove the Flush Valve items from the carton. The illustration below shows all items after
they have been removed from the carton. Some items may be packaged partially assembled to
other items.
CARE INSTRUCTIONS:
M965364 REV. 1.7 (5/19)
DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
Installation Instr
uctions
In
s
t
a
ll
a
t
io
n
I
n
s
t
r
u
c
t
io
n
s
M965364 REV. 1.7 (5/19)
MODEL NUMBERS
6045.601
Certified to comply with:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
© 2019 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic
®
Products visit our website at:
www.americanstandard-us.com
or e-mail us at:
For Parts, Service, Warranty or other Assistance,
please call
(844) CRT-TEAM / (844) 278-8326
(In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
Ultima
™
Manual
Urinal Flush Valve, Piston-Type
1-1/4" Top Spud, 1.0 gpf
OPERATING PRESSURE:
• 25 psi (flowing) - 80 psi (static)
FLOW REQUIREMENT:
• 10gpm (37.9 L/min).