Crown FM10000 Скачать руководство пользователя страница 32

Service and support    5 – 3  

Crown Broadcast Three Year Limited Product Warranty 

 

SUMMARY OF WARRANTY 

 

Crown Broadcast, IREC warrants its broadcast products to the ORIGINAL PURCHASER of a NEW Crown 
Broadcast product, for a period of three (3) years after shipment from Crown Broadcast. All products are 
warranted to be free of defects in materials and workmanship and meet or exeed all specifications published 
by Crown Broadcast. Product nameplate with serial number must be intact and not altered in any way. This 
warranty is non - transferable. This warranty in its entirety is the only warranty offered by Crown Broadcast. No 
other warranties, expressed or implied, will be enforceable. 

 

EXCLUSIONS

 

 

Crown Broadcast will not warranty the product due to misuse, accident, neglect and improper installation or 
operation. Proper installation included A/C line surge supression, lightning protection and proper grounding of 
the entire transmitter, and any other recommendations designated in the Instruction manual. This warranty  
does not extend to any other products other than those designed and manufactured by Crown Broadcast. This 
warranty does not cover any damage to any accessory such as loads, transmission line or antennas resulting 
from the use or failure of a Crown Broadcast transmitter. Warranty does not cover any loss of revenue resulting 
from any failure of a Crown Broadcast product, act of God, or natural disaster.

  

 

Procedure for Obtaining Warranty Service 

 

Crown Broadcast will repair or service, at our discretion, any product failure as a result of normal intended use. 
Warranty repair can only be performed at our plant facility in Elkhart, Indiana USA or at a factory authorized 
service depot. Expenses in remedying the defect will be borne by Crown Broadcast, including two-way ground 
transportation cost within the continental United States. 
Prior to returning any product or component to Crown Broadcast for warranty work or repair, a Return 
Authorization (RA) number must be obtained from the Crown Broadcast Customer Service Department. 
Product must be returned in the original factory pack or equivalent. Original factory pack materials may be 
obtained at a nominal charge by contacting Crown Broadcast Customer Service. Resolution of the defective 
product will be made within a reasonable time from the date of receipt of the defective product. 

 

Warranty Alterations 

 

No person has the authority to enlarge, amend, or modify this warranty, in whole or in part. This warranty is not 
extended by the length of time for which the owner was deprived the use of the product. Repairs and 
replacement parts that are provided under the terms of this warranty shall carry only the unexpired portion of 
the warranty. 

 

Product Design Changes 

 

Crown Broadcast reserves the right to change the design and manufacture of any product at any time without 
notice and without obligation to make corresponding changes in products previously manufactured. 

 

Legal Remedies of Purchaser 

 

This written warranty is given in lieu of any oral or implied warranties not covered herein. Crown 

Broadcast 

disclaims all implied warranties including any warranties of merchantability or fitness for a particular purpose. 

 

Crown Broadcast 

25166 Leer Drive 

Elkhart, Indiana 46514-5425 

Phone 574-262-8900  Fax 574-262-5399  

www.crownbroadcast.com

 

Содержание FM10000

Страница 1: ...i FM10000 RF Transmitter Package User s Manual 2006 Crown Broadcast a division of International Radio and Electronics Inc 25166 Leer Drive Elkhart Indiana 46514 5425 U S A 574 262 8900...

Страница 2: ...ced transmitted transcribed stored in a retrieval system or translated into any language in any form by any means without the written permission of Crown Broadcast Printed in U S A Crown attempts to p...

Страница 3: ...ck 2 3 2 4 2 Voltage Surge Protection Device 2 4 2 4 3 Low Pass Filter 2 4 2 4 4 Audio Input 2 4 2 5 Remote I O Connections 2 5 Section 3 Operation 3 1 Initial Power up Procedures 3 2 3 2 AC Power Swi...

Страница 4: ...System Block Diagram 4 4 4 3 Transmitter Controller Board Component ID 4 5 4 4 Transmitter Controller Board Schematic 4 6 Section 5 Service and Support 5 1 Service 5 2 5 2 24 Hour Support 5 2 5 3 Spar...

Страница 5: ...Section 1 Getting Acquainted This section provides a general description of the FM10000 transmitter system and introduces you to safety conventions used within this document Review this material befor...

Страница 6: ...iency of this transmitter significantly improves your bottom line by providing cooler operation and lower power costs These modular units are uniquely designed to be compact for convenient shipping an...

Страница 7: ...ypically 60 dB Operating Environment Temperature Range 0 50 C at sea level Humidity Range 0 80 at 20 C noncondensing AC Power 240 Volts AC 10 15 50 60 Hz with neutral Power Consumption Less than 18000...

Страница 8: ...rs DANGER represents the most severe hazard alert Extreme bodily harm or death will occur if DANGER guidelines are not followed 1 3 2 Warnings WARNING represents hazards which could result in severe i...

Страница 9: ...2 1 Installation Section 2 Installation This section provides important guidelines for installing your transmitter Review this information carefully for proper installation...

Страница 10: ...r on any flat surface which should be clean and well ventillated as possible 2 2 Tools Required To install the FM10000 you will need the following tools Medium phillips screwdriver Small flat blade sc...

Страница 11: ...2 3 Installation 2 4 Installation WARNING Possible Electric Shock Hazard Do not connect AC source until all other connections are made and installation is complete...

Страница 12: ...2 4 FM10000 User s Manual...

Страница 13: ...c HIGH 5 VDC when any fault light is ON 9 Ground 10 PA 5 ALC 11 PA 5 PA Temperature Celcius 1V 20 degrees C 12 PA 5 SWR 13 PA 5 RF Output power 1V 1000 Watts RF power 14 PA 5 In Ref 15 Remote RF Power...

Страница 14: ...ct reading of the ALC voltage on the PA 18 PA1 In Ref A DC voltage reference representing RF input power to the PA 19 PA2 RF Power 1V 1000 Watts of power 20 PA2 SWR Calculated reading of SWR in VDC 1...

Страница 15: ...of the ALC voltage on the PA 18 PA 3 In Ref A DC voltage reference representing RF input power to the PA 19 PA 4 RF Power 1V 1000 Watts of power 20 PA 4 SWR 21 Ground 22 PA 4 PA Volts 1V 10 V on the...

Страница 16: ...3 1 Operation Section 3 Operation This section provides general operating parameters of your transmitter system and a detailed description of the front panel displays...

Страница 17: ...ifier and power supply More detailed information follows 1 Ensure that the external remote control unit is properly connected to the transmitter controller port A see illustration 2 15 Section 2 5 pag...

Страница 18: ...3 3 Operation...

Страница 19: ...3 4 FM10000 User s Manual...

Страница 20: ...Operation 3 5...

Страница 21: ...3 6 FM10000 User s Manual...

Страница 22: ...Operation 3 7...

Страница 23: ...3 8 FM10000 User s Manual...

Страница 24: ...wings Section 4 Reference Drawings The illustrations in this section may be useful for making adjustments taking measurements troubleshooting or understanding the circuitry of your RF power amplifier...

Страница 25: ...t High Low 2 6 12 18 2 6 dB 12 dB 10 20 Expand Compress RF Power SWR ALC PA DC Volts PA DC Amps PA Temperature Supply DC Volts Voltmeter SWR Lock Input PA DC PA Temp Over 100 90 80 70 60 50 40 30 20 P...

Страница 26: ...Reference Drawings 4 3 Fault Antenna RF Drive PA Temp PA DC PA1 PA2 PA3 PA4 PA5 PA6 PA7 PA8 Power Out PA Temp PA Voltage Tot Current ALC SWR In Ref Metering PA1 PA2 PA3 PA4 PA5 PA6 PA7 PA8 Fuses...

Страница 27: ......

Страница 28: ......

Страница 29: ...9A 22A 10A 23A 11A 24A 12A 25A 13A J2A DB25STACKED 1A 14A 2A 15A 3A 16A 4A 17A 5A 18A 6A 19A 7A 20A 8A 21A 9A 22A 10A 23A 11A 24A 12A 25A 13A J3A DB25STACKED PA 4 RF output power PA 4 PA Volts PA 4 S...

Страница 30: ...ort Section 5 Service and Support We understand that you may need various levels of support or that the product could require servicing at some point in time This section provides information for both...

Страница 31: ...urned product 5 2 24 Hour Support In most instances what you need to know about your product can be found in this manual There are times when you may need more in depth information or even emergency t...

Страница 32: ...al intended use Warranty repair can only be performed at our plant facility in Elkhart Indiana USA or at a factory authorized service depot Expenses in remedying the defect will be borne by Crown Broa...

Страница 33: ...ges which we will reimburse We do not cover any charges for shipping outside the U S or any of the expenses involved in clearing customs If you have any questions about your Crown Broadcast product pl...

Страница 34: ...G 1 Glossary Glossary The following pages define terms and abbreviations used throughout this and other Crown Broadcast manuals A B C...

Страница 35: ...emphasis also called Wideband carrier A continuous signal which is modulated with a second information carrying signal crosstalk In FM broadcasting this term generally refers to the interaction betwe...

Страница 36: ...a Morse code rate Used in the on air identification of frequencies gain reduction The process of reducing the gain of a given ampli fier harmonics Undesirable energy at integral multiples of a desire...

Страница 37: ...pectrum between audio fre quency and the infrared portion 2 A frequency useful for radio transmission roughly 10 kHz and 100 000 MHz SCA Subsidiary Communications Authorization see subcarrier S N Sign...

Страница 38: ...mitter designed to internally change an FM signal from one frequency to another for retrans mission Used in conjunction with terrestrial fed networks satellator A transmitter equipped with an FSK ID o...

Отзывы: