Installation 2–5
1
25
13
14
Port A
Pin
Description
1
PA # 5 - # 8 current 1V = 2A of current
2
PA # 5 - # 7 current 1V = 2A of current
3
System Lock-Out Reset - Momentary to Ground to reset power control to normal
4 Remote RF Power RAISE - Momentary to Gnd to raise power 2
00 watts/second
5
Cabinet Temperature - 0.01 Volts/degrees Celsius reading of internal cabinet temp.
6
Ground
7
Remote High Voltage ON/OFF - Hold to ground to turn ON High Voltage
8
Fault Summary - TTL Logic HIGH (+5 VDC) when any fault light is ON
9
Ground
10
PA # 5 - ALC
11
PA # 5 - PA Temperature (Celcius) 1V = 20 degrees C
12
PA # 5 - SWR
13
PA # 5 - RF Output power 1V = 1000 Watts RF power
14
PA # 5 - In Ref.
15
Remote RF Power LOWER - Momentary to Gnd to lower power 20 watts/second
16
PA # 5 - # 6 current 1V = 2A of current
17
PA # 5 - # 5 current 1V = 2A of current
18
Remote RF Power, Forward - 1 VDC = 1000 Watts of Forward power
19
PA # 5 - # 4 current 1V = 2A of current
20
PA # 5 - # 3 current 1V = 2A of current
21
Remote RF Power, Reverse - 1 VDC = 1000 Watts of Reverse power
22
PA # 5 - # 2 current 1V = 2A of current
23
PA # 5 - # 1 current 1V = 2A of current
24
PA # 5 - PA Total Current 1V = 20 Amps
25
PA # 5 - PA Volts 1V = 10 Volts
Содержание FM10000
Страница 12: ...2 4 FM10000 User s Manual...
Страница 18: ...3 3 Operation...
Страница 19: ...3 4 FM10000 User s Manual...
Страница 20: ...Operation 3 5...
Страница 21: ...3 6 FM10000 User s Manual...
Страница 22: ...Operation 3 7...
Страница 23: ...3 8 FM10000 User s Manual...
Страница 27: ......
Страница 28: ......