INSTALLATION & OPERATION MANUAL 10121 REV 0 (04/21)
PAGE
4
OF 20
Self-Generating Steam Jacketed Counter Tilting Kettles
S
ervice
C
onnections
S
ervice
C
onnections
As continued product improvement is a policy of Crown, specifications are subject to changge without notice.
ELECTRICAL CHARACTERISTICS AND SPECIFICATIONS
DIMENSIONS
SERVICE CONNECTIONS
- ELECTRICAL CONNECTIONS: to be specified on data plate
- COLD WATER: 3/8” O.D. tubing to faucet (OPTIONAL)
- HOT WATER: 3/8” O.D. tubing to faucet (OPTIONAL)
C
H
Model
Capacity
Units
A
B
C
D
E
F
G
H
J
K
L
EC-6TW
6 gallons
23 liters
in
(mm)
12”
(305)
14.38”
(365)
24”
(610)
33.5”
(851)
15.25”
(387)
22.25”
(565)
4.50”
(114)
27”
(686)
4.25”
(108)
12.38”
(314)
10”
(254)
EC-10TW
10 gallons
38 liters
in
(mm)
16”
(406)
15”
(381)
26”
(660)
34.88”
(886)
17.25”
(438)
26.25”
(667)
4.62”
(117)
28”
(711)
6.12”
(156)
14.75”
(375)
12.75”
(324)
EC-12TW 12 gallons 45
liters
in
(mm)
16”
(406)
17”
(432)
28”
(711)
36.88”
(937)
17.25”
(438)
26.25”
(667)
4.12”
(105)
30”
(762)
6.12”
(156)
14.75”
(375)
12.75”
(324)
Model
Shipping
Weight
Minimum Clearance
Capacities
Right Side Left Side
Back
kW
US Gal. Liters
EC-6TW
120 lbs.
[54 kg]
0”
3”
(76 mm)
2.5”
(64 mm)
7.5
6
23
EC-10TW 159 lbs.
[72 kg]
0”
3”
(76 mm)
2”
(51 mm)
12
10
38
EC-12TW 190 lbs.
[86 kg]
0”
3”
(76 mm)
2”
(51 mm)
12
12
45
Model
Phase kW
Amps Per Line
208V 220V 240V 380V 415V 480V 600V
EC-6TW
1
7.5 36.0 34.1 31.3
-
-
-
-
3
7.5 20.8 19.7 18.1 11.4 10.4
9.0
7.2
EC-10TW
EC-12TW
1
12.0 57.6 54.6 50.0
-
-
-
-
3
12.0 33.3 31.5 28.9 18.3 16.7 14.5 11.5