background image

DriveCore Install Network Series 

Power Amplifiers

page 63

Operation Manual

Warranty 

SUMMARY OF WARRANTY 

Crown International, 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL 

PURCHASER and ANY SUBSEQUENT OWNER of each NEW Crown product, for a period of three (3) years from the date of 

purchase by the original purchaser (the “warranty period”) that the new Crown product is free of defects in materials and 

workmanship. We further warrant the new Crown product regardless of the reason for failure, except as excluded in this 

Warranty.

*Warranty is only valid within the United States of America. For information on Warranty outside of the U.S.A, please contact 

your local distributor.

ITEMS EXCLUDED FROM THIS CROWN WARRANTY 

This Crown Warranty is in effect only for failure of a new Crown product which occurred within the Warranty Period. It does 

not cover any product which has been damaged because of any intentional misuse, accident, negligence, or loss which is 

covered under any of your insurance contracts. This Crown Warranty also does not extend to the new Crown product if the 

serial number has been defaced, altered, or removed.

WHAT THE WARRANTOR WILL DO 

We will remedy any defect, regardless of the reason for failure (except as excluded), by repair, replacement, or refund. We 

may not elect refund unless you agree, or unless we are unable to provide replacement, and repair is not practical or cannot 

be timely made. If a refund is elected, then you must make the defective or malfunctioning product available to us free 

and clear of all liens or other encumbrances. The refund will be equal to the actual purchase price, not including interest, 

insurance, closing costs, and other finance charges less a reasonable depreciation on the product from the date of original 

purchase. Warranty work can only be performed at our authorized service centers or at the factory. Warranty work for some 

products can only be performed at our factory. We will remedy the defect and ship the product from the service center or 

our factory within a reasonable time after receipt of the defective product at our authorized service center or our factory. All 

expenses in remedying the defect, including surface shipping costs in the United States, will be borne by us. (You must bear 

the expense of shipping the product between any foreign country and the port of entry in the United States including the 

return shipment, and all taxes, duties, and other customs fees for such foreign shipments.)

HOW TO OBTAIN WARRANTY SERVICE 

You must notify us of your need for warranty service within the warranty period. All components must be shipped in a factory 

pack, which, if needed, may be obtained from us free of charge. Corrective action will be taken within a reasonable time of 

the date of receipt of the defective product by us or our authorized service center. If the repairs made by us or our authorized 

service center are not satisfactory, notify us or our authorized service center immediately.

DISCLAIMER OF CONSEQUENTIAL AND INCIDENTAL DAMAGES 

YOU ARE NOT ENTITLED TO RECOVER FROM US ANY INCIDENTAL DAMAGES RESULTING FROM ANY DEFECT IN 

THE NEW CROWN PRODUCT. THIS INCLUDES ANY DAMAGE TO ANOTHER PRODUCT OR PRODUCTS RESULTING 

FROM SUCH A DEFECT. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR 

CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.

WARRANTY ALTERATIONS 

No person has the authority to enlarge, amend, or modify this Crown Warranty. This Crown Warranty is not extended by the 

length of time which you are deprived of the use of the new Crown product. Repairs and replacement parts provided under 

the terms of this Crown Warranty shall carry only the unexpired portion of this Crown Warranty.

DESIGN CHANGES 

We reserve the right to change the design of any product from time to time without notice and with no obligation to make 

corresponding changes in products previously manufactured.

LEGAL REMEDIES OF PURCHASER 

THIS CROWN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY 

FROM STATE TO STATE. No action to enforce this Crown Warranty shall be commenced after expiration of the warranty 

period.

THIS STATEMENT OF WARRANTY SUPERSEDES ANY OTHERS CONTAINED IN THIS MANUAL FOR CROWN PRODUCTS.  

03/13

Содержание DCi 2 300N

Страница 1: ...blication date However updates to this information may have occurred To obtain the latest version of this manual please visit the Crown website at www crownaudio com Trademark Notice Com Tech BCA Crow...

Страница 2: ...THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL REMAIN READILY OPERABLE WATCH FOR THESE SYMBOLS The lightning bolt triangle is used to alert the user to the risk of electric shock The exclamation point...

Страница 3: ...art 2 Immunity EN 61000 4 2 2008 Ed 2 0 EMC Compatibility Product Family Standard for Audio Video Audio Visual and Entertainment Lighting Control Apparatus for Professional Use Part 2 Immunity EN 6100...

Страница 4: ...7 Set up and System Configuration 8 Netsetter 10 Offline Online Operation 16 Precautions 25 General Purpose In Out Control Port 26 Aux Port Sleep Amp Status 31 BLU Link 32 Advanced Operation 36 Per C...

Страница 5: ...lters Crossover Input Output Delay LevelMAXTM Limiters Priority Input Router PFC Power Supply Universal PFC Power Supply for reduced current draw and provides industry leading efficiency Monitoring an...

Страница 6: ...ginning of this manual Install the Amplifier CAUTION Before you begin make sure your amplifier is disconnected from the power source and that all level controls see Page 7 are set to knob Counterclock...

Страница 7: ...ier is in sleep mode Bridge Mode Indicator yellow Illuminates when when Bridge Mode is activated for the channel pair only odd number channel will be active Note Eight channel model shown Indications...

Страница 8: ...mum limit of 60 BLU Link nodes for each audio ring Wire Output Connectors Crown has designed an output cover that does not need to be removed to connect the output wiring Crown recommends using the in...

Страница 9: ...els 3 4 on four channel models and for channels 5 6 and 7 8 on eight channel models Each channel may be configured independently on multichannel models Set up and System Configuration Figure 1 Set Up...

Страница 10: ...cting a new NIC will force a rescan of the network to which the new NIC is connected Display This menu filters the device in the grid view by All Devices Default setting All discovered devices are dis...

Страница 11: ...pop up Clicking OK will apply the edits you have made since opening NetSetter Clicking Cancel will return you to the program The NetSetter Grid The grid is divided into 12 sections 1 MAC Address 7 Ran...

Страница 12: ...been made it is critical to click the Apply Current Edits or Apply and Exit buttons Subnet Mask Displays the Subnet Mask of the discovered device The Subnet Mask may be edited inline The device row wi...

Страница 13: ...ed If all devices in the current filter view are set to Random ID on and the Random HiQnet ID column header check box is checked all devices may be set to Random ID off by unchecking the column header...

Страница 14: ...y need to be reset on rediscovery after applying current edits requiring the Admin password to be entered again Discovering The Discovering status is determined by the following conditions The device...

Страница 15: ...PCs running an instance of HiQnet software System Architect Performance Manager London Architect The Container Position Venue Data may not be edited inline A selected device may have its Venue Data cl...

Страница 16: ...cally enables matching between all the devices in the Audio Architect venue Detach Removes the device s virtual connection from Audio Architect Editing Undo Erases the last change done reverting to th...

Страница 17: ...tomatically removed from the Discovered Factory Master Panels Monitor Panels Meter Panels Level and Mute Panels Double clicking an amplifier will access the amplifier factor control panel At this poin...

Страница 18: ...l Network amplifiers are capable of High Z and Low Z outputs Each individual channel is capable of Hi Z or Low Z operation To select Hi Z or Low Z operation double click on the mode button the Amplifi...

Страница 19: ...e 9 One input can be used to drive some or all of the amplifier outputs NOTE By cascading the inputs the corresponding input DSP functions for individual channels will be removed and only the output D...

Страница 20: ...the Amplifier Mode window By selecting the bridging option only the first input channel will need to be wired See Figure 11 Low Z and High Z options are still available NOTE If the amplifier output i...

Страница 21: ...important to understand that BLU Link is a digital audio bus and cannot be routed through a network switch or router To increase fault protection use both the input and output BLU Link wiring connect...

Страница 22: ...tand that BLU Link is a digital audio bus and cannot be routed through a network switch or router To increase fault protection use both the input and output BLU Link wiring connection For BLU Link rou...

Страница 23: ...automatically when the amplifier channel is in Hi Z or Bridged Hi Z mode Remember DCi amplifiers allow each channel Hi Z or Low Z mode of operation to be selected independently while 70V 100V selecti...

Страница 24: ...tive OUTPUTS Connect the speaker across the positive terminals of each channel pair Do not use the negative terminals of the channel pair when the pair is being operated in Bridge Mono mode NOTE For g...

Страница 25: ...r connect the output to a power supply battery or power main Electrical shock may result 5 Tampering with the circuitry or making unauthorized circuit changes may be hazardous and invalidate all agenc...

Страница 26: ...the control port input is at the minimum end of its range Mode For the control port input the Mode field determines how the assigned parameters will be controlled For the control port output the Mode...

Страница 27: ...1 or 2 Once an SV has been added its type will determine which MODE options become available If a binary SV has been assigned only the Direct Action mode is selectable and the ON VALUE and OFF VALUE...

Страница 28: ...as been assigned and the MODE has been set any subsequent SV that is added must function in the same MODE Up to 40 SV s can be assigned to a given input An assigned state variable can be removed by hi...

Страница 29: ...rol Port output configuration options can be found directly below those for the input No parameters can be assigned to the outputs Instead there are three modes available Manual Report Errors and Repo...

Страница 30: ...Operation Manual page 30 General Purpose In Out Control Port NOTE that in all modes the polarity of the binary output can be toggled under the OUTPUT POLARITY tab where Normal or Inverted can be sele...

Страница 31: ...hen the connection between pins 1 and 2 is open the amplifier will revert to its last configuration and begin to output audio within 20 seconds Communication via the network will take as long as the n...

Страница 32: ...cted and the other will detect that its Out port is undetected NOTE when the cable is broken the audio takes longer to reach its destination than before This added delay is not compensated for in any...

Страница 33: ...Routing Input Configuration The DriveCore Install Network Amplifiers series can utilize both analog or BLU Link inputs To configured the input section of the amplifier Input Icon Source Routing Input...

Страница 34: ...Channels Then go to Source Routing to assign that audio stream to an amplifier channel by selecting BLU Link Input 1 through 8 from the dropdown menus presented Output Configuration Double clicking o...

Страница 35: ...N amp channel to 1 of the 8 available BLU Link outputs NOTE The post processing audio is bussed from a point at the end of the entire channel processing chain in the DCI N This is effectively analogou...

Страница 36: ...ps outlines setting up User Presets 1 Adjust the DSP settings as desired in the Audio Architect software 2 Save this group of settings as preset you will be prompted to name it 3 Download the preset t...

Страница 37: ...DriveCore Install Network Series Power Amplifiers page 37 Operation Manual Figure 23 Signal Path...

Страница 38: ...is hovered over the respective channel Speaker Tuning Icon Figure 24 Basic Speaker Tuning Panel Speaker Tunings Crown and JBL engineers have designed DriveCore Install DSP settings that are opti mized...

Страница 39: ...from 0S to 2S 6 Band Gain adjustable from 100dB to 20dB in 0 5dB steps 7 Polarity Invert Speaker Tuning Libraries The new system uses software based Speaker Tuning Libraries Audio Architect manages t...

Страница 40: ...he working library This action replaces the current working library Any changes not saved to the existing working library will be lost Saving a Library Click on the File Save Speaker Tuning dialog on...

Страница 41: ...or this DSP are Configure signal flow Optimize system gain structure Configure speaker configurations set the drive levels frequency bands delays and limiting for your particular speakers Configure EQ...

Страница 42: ...o Router Clip Indicator Peak RMS levels Output Signal Level Meter blue The measurement range is from 0 dB to 40 dB with 0 5 dB resolution The monitors are scaled so that 0 dB is referenced to the full...

Страница 43: ...nnels This does not represent 1 256 but rather the BLU Link input channels that have been selected for the amplifier Digital with Analog Backup The input takes the digital signal as its source when th...

Страница 44: ...secondary input will be engaged Attack Defined as the time it takes for the secondary source to engage This can range from 0 1 seconds to 1 0 seconds Release Defined as the time it takes for the prima...

Страница 45: ...0 1 seconds of output delay is provided See Figure 30 Input Output Equalization These screens let you adjust channel equalization for up to 8 frequencies You can select filter type frequency gain and...

Страница 46: ...lable plus crossover filters Each filter has up to 24dB of gain The following filters are available Lowpass Highpass Bessel 12dB oct 18dB oct 24dB oct 30dB oct 36dB oct 42dB oct 48dB oct Butterworth 1...

Страница 47: ...oltage which the limiter will allow from the amplifier The range is from 1 Vpk to 255 Vpk Attack Time Sets the attack time of the limiter The attack time is defined as the time it takes the limiter to...

Страница 48: ...Use a flat blade screwdriver to set input level Attenuation is from 95 dB full counter clockwise to 0 dB full clockwise For gain structure purposes it is important to note that attenuators are at the...

Страница 49: ...es above 10 of the nominal operating voltage of the amplifier the amplifier s power supply turns off and the blue Power LED flashes The amplifier will turn back on when the AC line voltage returns to...

Страница 50: ...t ting CONDITION Power indicator is off Mains indicator is on POSSIBLE REASON The amplifier s Power switch is off CONDITION Power indicator is off Mains indicator is off POSSIBLE REASON The power supp...

Страница 51: ...the mixer or preamp Off Flashing On above means that the LED can be off or flashing or on CONDITION No sound even though the amp has power Power LED is on with out flashing and the amp is receiving a...

Страница 52: ...s lit POSSIBLE REASON Amplifierisinbridge monomode CONDITION No input signal Signal indicator is not flashing even though audio is applied and the channel is ready POSSIBLE REASON Input signal level i...

Страница 53: ...ty DCi Network Model Channels 2 Ohms 4 Ohms 8 Ohms 16 Ohms 70Vrms 100Vrms 2 300N 2 150W 300W 300W 150W 300W 300W 2 600N 2 300W 600W 600W 300W 600W 600W 4 300N 4 150W 300W 300W 150W 300W 300W 4 600N 4...

Страница 54: ...Impedance Nomminally bal anced nominally unbalanced 10 kOhms 5 kOhms 10 kOhms 5 kOhms 10 kOhms 5 kOhms 10 kOhms 5 kOhms 10 kOhms 5 kOhms 10 kOhms 5 kOhms Maximum Input Level Low Gain Mode 20dBU 20dBU...

Страница 55: ...pical of program material at extreme clip 4 ohms 1 9 108 370 93 1 0 105 357 90 8 ohms 2 7 113 387 98 1 4 106 363 92 16 ohms 2 7 99 339 85 1 3 89 305 77 140V 32 67 ohms 2 4 86 295 74 1 3 82 280 70 200V...

Страница 56: ...ogram material at extreme clip 4 ohms 2 8 128 438 110 1 6 133 453 114 8 ohms 4 8 157 536 135 2 5 148 505 127 16 ohms 4 6 130 444 112 2 3 118 403 102 140V 16 ohms 4 6 125 427 108 2 3 117 399 101 200V 3...

Страница 57: ...m material at extreme clip 4 ohms 3 2 190 650 164 1 7 185 630 159 8 ohms 5 2 205 699 176 2 6 194 664 167 16 ohms 4 9 171 583 147 2 5 168 575 145 140V 32 67 ohms 4 7 157 535 135 2 4 153 523 132 200V 66...

Страница 58: ...gram material at extreme clip 4 ohms 5 6 247 844 213 2 9 235 801 202 8 ohms 9 5 298 1018 257 4 8 269 916 231 16 ohms 8 7 223 760 192 4 5 207 705 178 140V 16 ohms 8 7 230 786 198 4 5 214 730 184 200V 3...

Страница 59: ...t extreme clip 2 ohms 6 7 353 1206 304 3 4 343 1171 295 4 ohms 9 9 341 1165 294 5 0 318 1085 273 8 ohms 9 5 312 1066 269 4 8 293 1000 252 70V 16 33 ohms 9 4 304 1037 262 4 8 275 938 237 100V 33 33 ohm...

Страница 60: ...treme clip 4 ohms 10 8 468 1597 403 5 4 445 1519 383 8 ohms 17 9 530 1810 456 9 0 476 1625 410 16 ohms 17 0 421 1437 362 8 7 389 1328 335 140V 16 ohms 17 3 439 1500 378 8 8 382 1305 329 200V 33 33 ohm...

Страница 61: ...sale along with the defective unit to an authorized service center to obtain service They will handle the necessary paperwork and repair Remem ber to transport the unit in the original factory pack A...

Страница 62: ...pack material Do not ship your unit in a wood or metal cabinet 4 If you provide your own shipping pack the minimum recommended requirements for materials are as follows a 275 P S I burst test Double W...

Страница 63: ...tory within a reasonable time after receipt of the defective product at our authorized service center or our factory All expenses in remedying the defect including surface shipping costs in the United...

Страница 64: ..._______________________________________________________________________________________________________ ________________________________________________________________________________________________...

Страница 65: ...___________________________________________________________ Phone include area code ______________________________________ Fax ____________________________________________________ PRODUCT INFORMATION...

Страница 66: ......

Отзывы: