DriveCore Install Network Series
Power Amplifiers
page 55
Operation Manual
AC Power Draw and Thermal Dissipation
AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Data based on all channels driven.
DCi 2|300N - Bridge
120 VAC / 60 Hz
230 VAC / 50 Hz
Condition
Load
"Line cur-
rent
(amps)"
Power Dissipated as Heat
"Line cur-
rent
(amps)"
Power Dissipated as Heat
watts
BTU
kcal/hr
watts
BTU
kcal/hr
At Idle Awake
N/A
0.6
67
229
58
0.4
68
231
58
1/8 Power
Pink Noise
Typical of program
material just at clip
4 ohms
1.1
86
293
74
0.6
83
284
72
8 ohms
1.4
88
300
76
0.8
86
293
74
16 ohms
1.4
83
282
71
0.7
78
267
67
140V
(32.67 ohms)
1.3
78
265
67
0.7
74
252
64
200V
(66.67 ohms)
1.3
76
260
66
0.7
72
246
62
1/3 Power
Pink Noise
Typical of program
material at
extreme clip
4 ohms
1.9
108
370
93
1.0
105
357
90
8 ohms
2.7
113
387
98
1.4
106
363
92
16 ohms
2.7
99
339
85
1.3
89
305
77
140V
(32.67 ohms)
2.4
86
295
74
1.3
82
280
70
200V
(66.67 ohms)
2.5
87
295
74
1.3
80
273
69
DCi 2|300N - Dual
120 VAC / 60 Hz
230 VAC / 50 Hz
Condition
Load
"Line cur-
rent
(amps)"
Power Dissipated as Heat
"Line cur-
rent
(amps)"
Power Dissipated as Heat
watts
BTU
kcal/hr
watts
BTU
kcal/hr
At Idle Awake
N/A
0.6
70
240
60
0.4
68
231
58
1/8 Power
Pink Noise
Typical of program
material just at clip
2 ohms
1.1
85
291
73
0.6
83
284
72
4 ohms
1.4
89
304
77
0.8
85
289
73
8 ohms
1.4
83
282
71
0.7
79
269
68
70V
(16.33 ohms)
1.3
78
265
67
0.7
75
256
65
100V
(33.33 ohms)
1.3
77
263
66
0.7
73
248
63
1/3 Power
Pink Noise
Typical of program
material at
extreme clip
2 ohms
1.9
109
373
94
1.0
104
356
90
4 ohms
2.7
113
387
98
1.4
105
359
90
8 ohms
2.5
99
339
85
1.3
93
316
80
70V
(16.33 ohms)
2.5
89
304
77
1.3
82
279
70
100V
(33.33 ohms)
2.5
82
280
70
1.3
81
276
69
Содержание DCi 2 300N
Страница 37: ...DriveCore Install Network Series Power Amplifiers page 37 Operation Manual Figure 23 Signal Path...
Страница 66: ......