background image

Operation Manual

CTs Multi-Channel Power Amplifiers

page 30

page 31

CTs Multi-Channel Power Amplifiers

Operation Manual

Figure 6.1 CTs 
4200USP/CN 
Minimum 
Guaranteed  
Power

Figure 6.2 CTs 
8200USP/CN 
Minimum 
Guaranteed 
Power

Channels Driven

2

4

1

2

1

1 kHz

20 Hz - 20 kHz

1 kHz

1 kHz

20 Hz - 20 kHz

4 Ohm

260

215

270

270

225

8 Ohm

180

190

210

220

210

70V (25 Ohm) at 0.1% THD

220

220*

240

250

 245*

Channel Pairs Driven

1 kHz

20 Hz - 20 kHz

1 kHz

20 Hz - 20 kHz

520

430

560

450

400

380

440

420

220

220*

250

 245*

8 Ohm
16 Ohm
100V (50 Ohm)

Bridge-Mono Mode

CTs 4200USP/CN: MINIMUM GUARANTEED POWER   

(in watts, 0.1% THD) 120VAC, 60 Hz units

Dual Mode

at 0.1% THD

* Constant Voltage full bandwidth power ratings support 100 Hz - 20 kHz due to automatic high-pass filters.

160

200

200

175
155
185*

250
190
220

260
200

240

270

220
250

230
220
230*

400
320

200

350
310

185*

540
440
250

460
440

230*

500
380
220

Bridge-Mono Mode

8 Ohm

16 Ohm
100V (50 Ohm) at 0.1% THD

70V (25 Ohm) at 0.1% THD

8 Ohm

4 Ohm

Channels Driven

Dual Mode

1 kHz

1 kHz

1 kHz

1 kHz

20 Hz - 20 kHz

1 kHz

20 Hz - 20 kHz

20 Hz - 20 kHz

1 kHz

1 kHz

20 Hz - 20 kHz

CTs 8200USP/CN: MINIMUM GUARANTEED POWER 

(In watts, 0.1% THD) 120VAC, 60 Hz units

8

4

2

1

4

2

1

* Constant Voltage full bandwidth power ratings support 100 Hz - 20 kHz due to automatic high-pass filters.

AC Power Draw and Thermal Dissipation:

Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.

watts in

watts out

dissapated

Btu/hr

kcal/hr

At Idle (8.4 Ohm mode )

70

0

70

239

60

At Idle (70/100V mode)

114

0

114

389

98

1/8th Power Pink Noise

8 Ohms/Ch.

200x4

Typical of program material 

16 Ohms Bridge

400x2

just at clip.

4 Ohms/Ch.

260x4

8 Ohms Bridge

520x2

70V/Ch.

220x4

100V Bridge

220x2

1/3rd Power Pink Noise

8 Ohms/Ch.

200x4

Typical of program material

16 Ohms Bridge

400x2

with severe clipping.

4 Ohms/Ch.

260x4

8 Ohms Bridge

520x2

70V/Ch.

220x4

100V Bridge

220x2

382

1303

329

7.9

4.0

668

286

391

1336

337

11.8

5.9

1005

349

655

2236

564

7.6

3.8

648

257

318

1084

273

5.3

2.7

427

110

301

1027

259

7.8

3.9

639

134

505

1722

434

5.2

2.6

400

99

CTs 4200

Load

Rated 

Power

Line Current 

120VAC

Line Current 

230VAC

Watts 

Thermal Dissipation

7 AC Power Draw and 

Thermal Dissipation

6 Specifications  

(continued)

Содержание CTs 4200USP/CN

Страница 1: ...n this manual was deemed accurate as of the publication date However updates to this information may have occurred To obtain the latest version of this manual please visit the Crown website at www cro...

Страница 2: ...riesgo de un choque el ctrico El tri ngulo con el signo de admiraci n es usado para alertar al usuario de instrucciones importantes de operaci n o man tenimiento WATCH FOR THESE SYMBOLS IMPORTANT CTs...

Страница 3: ...e take the time to study this manual so that you can obtain the best possible service from your amplifier 1 1 Features Crown Switching Power Supply for reduced weight High power density with eight cha...

Страница 4: ...of the rack should be open Figure 2 2 illustrates standard amplifier airflow 2 Setup Figure 2 1 Dimensions Left CTs 4200USP CN Right CTs 8200USP CN Figure 2 2 Airflow 2 4 Front Panel Controls and Indi...

Страница 5: ...the Mode switch setting If this is not done the Bridge light will flash to indicate that the power must be cycled off and back on to reset the mode Q Cooling Vents Front to rear forced airflow 2 Setup...

Страница 6: ...or damage to the amplifier may result CAUTION Never use shielded cable for output wiring Figure 2 6 Balanced Input Connector Wiring See the Crown Amplifier Appli cation Guide available online at www...

Страница 7: ...be a stan dalone or separate network LAN Crown strongly recommends the use of a 100 Mb Ether net network for control and monitoring If network redundancy is required use a standard CAT5 cable to conn...

Страница 8: ...fic the indicator flashes The Link Activity LED flashes for all network traffic while the Data LED flashes only for commands addressed to this USP CN 3 2 5 CobraNet In Use Conductor Indicator The indi...

Страница 9: ...error never being detected THERMAL Errors can be generated for excessive temperature in the output section of the amplifier channel The Threshold Control sets the level that if exceeded will generate...

Страница 10: ...ng type system to continually drive the speaker allowing continuous mon itoring of the speaker load The following controls exist Sine On Off The sine wave signal generator s function Sine Frequency Co...

Страница 11: ...1 AUX Output Control of a Relay The AUX output has two enhanced modes Error Reporting and Flash Preset In Error Reporting mode the AUX port can be set up to change state when any selected error clip...

Страница 12: ...sult your electrician Models Under Voltage Limit Over Voltage Limit 100VAC 90VAC 110VAC 120 VAC units 108VAC 132VAC 220V 230V 240V units 198VAC 264VAC 4 2 6 Power Fuse A fuse protects the amplifier fr...

Страница 13: ...ve Note If the signal sounds distorted even though the Clip LED is off the input signal is distorted Check gain staging and output lev els of the mixer or preamp 5 Troubleshooting CONDITION No sound e...

Страница 14: ...r 10 Hz to 400 Hz 180 180 Crosstalk below rated power 20 Hz to 1 kHz 80 dB 80 dB Common Mode Rejection CMR 20 Hz to 1 kHz 50 dB 50 dB DC Output Offset Shorted input 5 mV 5 mV Input Impedance nominal b...

Страница 15: ...ons continued Figure 6 1 CTs 8200USP CN Typical Frequency Response 1 W Figure 6 2 CTs 8200USP CN Typical Phase Response 1 W Figure 6 3 CTs 8200USP CN Typical Damping Factor vs Frequency 6 Specificatio...

Страница 16: ...z CTs 8200USP CN MINIMUM GUARANTEED POWER In watts 0 1 THD 120VAC 60 Hz units 8 4 2 1 4 2 1 Constant Voltage full bandwidth power ratings support 100 Hz 20 kHz due to automatic high pass filters AC Po...

Страница 17: ...ntages over other non network communications platforms Figure 8 1 A Typical TCP IP Network The use of off the shelf networking hardware This technology makes use of network connectivity and hardware c...

Страница 18: ...Latency The transmitter and receiver buffering required for reliable transmission is selectable between 1 33 2 66 and 5 33 ms 64 128 and 256 samples 8 2 3 Bundles and Audio Channels You will be assig...

Страница 19: ...ice Shipping Instruc tions 1 Service Return Authorization SRA is required for product being sent to the factory for service Please complete the SRA by going to www crownaudio com support factserv htm...

Страница 20: ...service center or our factory within a reasonable time after receipt of the defec tive product at our authorized service center or our factory All expenses in remedying the defect including surface sh...

Страница 21: ...______________ State ___________________________ Zip Code ________________ Country __________________________ E mail address ___________________________________________ Phone include area code _______...

Страница 22: ..._________________ ___________________________________________________________________________________________________________________________________________________________________________ Other equi...

Страница 23: ......

Отзывы: