Problem: 

Green Preset indicator is flashing, or is not flashing.

Possible cause: 

This is not a problem. This indicator signals the 

number of the current preset, if active, by flashing a series of flashes 
equal to the current preset number. A preset is considered “active” if 
the USP/CN settings match those in the selected preset. If a change is 
made to any setting then the preset is considered “inactive,” and the 
indicator stops flashing.

Problem: 

Both right indicators flash yellow in unison to report a fatal 

error.

Possible cause:

 

An unexpected condition within the CobraNet 

inter face has been detected. 

NOTE: Actual product artwork may vary slightly.

5 Troubleshooting

 (continued)

Problem: 

Data indicator is not flashing, even though a valid 

com mand was sent.

Possible causes: 

• Command was not addressed to the USP/CN.
• Network cable is disconnected or broken.

To assist with troubleshooting, System Architect can set an option for 
force the data indicator on.

Problem: 

Green LINK/ACTIVITY indicator in network connector does 

not illuminate or flash.

Possible cause:

 Ethernet link is broken, or network connection is 10 

Mbps. Check Ethernet connections to the network switch.

Problem:

 

Computer does not communicate with the network 

devices.   

Possible cause:

 Incorrect wiring. See Section 2.10 on network 

wiring.

   

Performance

CTs 4200USP/CN

CTs 8200USP/CN

Frequency Response (at 1 watt, 20 Hz - 20 kHz)

± 0.5 dB

± 0.5 dB

Phase Response (at 1 watt, 10 Hz - 20 kHz)

± 35°

± 35°

Signal to Noise Ratio below rated power (20 Hz to 20 kHz)

100 dB unweighted

100 dB unweighted

Total Harmonic Distortion (THD) at 1 watt, from 20 Hz to 20 kHz

< 0.05%

< 0.05%

Intermodulation Distortion (IMD) 60 Hz and 7 kHz at 4:1, 

from 163 milliwatts to full bandwidth power, typical

< 0.05%

< 0.05%

Damping Factor: 10 Hz to 400 Hz

>180

>180

Crosstalk (below rated power, 20 Hz to 1 kHz)

> 80 dB

> 80 dB

Common Mode Rejection (CMR) (20 Hz to 1 kHz)

> 50 dB

> 50 dB

DC Output Offset (Shorted input)

< ± 5 mV

< ± 5 mV

Input Impedance (nominal) (balanced, unbalanced)

20 kilohms, 10 kilohms

20 kilohms, 10 kilohms

Maximum Input Level (before input compression)

+ 20 dBu

+ 20 dBu

Load Impedance (Note: Safe with all types of loads)  

      Stereo 

      Bridge Mono

 

4/8 and 25 ohms (70V)  

8/16 and 50 ohms (100V) 

 

4/8 and 25 ohms (70V)  

8/16 and 50 ohms(100V) 

Voltage Gain (at maximum level setting), 1.4V sensitivity 

     4/8 Ohm Operation 

     70V Operation 

     100V Operation

 

20:1 (26 dB) 

50:1 (34 dB) 

71.4:1 (37 dB)

 

20:1 (26 dB) 

50:1 (34 dB) 

71.4:1 (37 dB)

Required AC Mains (model dependent)

120V, 60 Hz. 220/230/240V, 50 Hz

100V, 50/60  Hz. 120V, 60 Hz. 220/230/240V, 50 Hz

Power Draw at Idle (120VAC mains, all channels in 4/8 ohm mode)

70W

70W

Power Draw at Idle (120VAC mains, all channels in 70V mode)

114W

114W

Cooling

Continuously variable speed forced air, front-to-back airflow

Continuously variable speed forced air, front-to-back airflow

Dimensions: Width, Height, Depth

19 in. (48.3 cm) W x 3.5 in. (8.9 cm) H x 16.25 in. (41.3 cm) D

19 in. (48.3 cm) W x 5.25 in. (13.3 cm) H x 16.25 in. (41.3 cm) D

Net Weight, Shipping Weight

26 lb. 6 oz. (12 kg), 30 lb. 14 oz. (14 kg) 

36 lb. 6 oz. (16.5 kg), 47 lb. (21.3 kg)                                                 

The following specifications apply to all models in Dual 8/4 ohm mode with 8-ohm loads unless otherwise specified.

6 Specifications

USP/CN (CobraNet Module) 

Specifications

Memory Backup:

 4 Megabit non-volatile FLASH memories for 

backup of run-time parameters, presets, and program storage. 
Capa ble of 10,000 write cycles. 

Communications: 

100 Mb Fast Ethernet conforming to IEEE 802.3.

Overall Audio Performance:
DSP Processing

: Two processors, 32 bit, floating point, 724 µs 

latency.

DAC Conversion: 

24 bit, 250 µs latency.

Dynamic Range: 

103 dB typical (A-weighted, 20Hz–20kHz, audio 

sourced from muted CobraNet channel).

Distortion: 

< 0.1% THD+N, 20Hz–20kHz.

Frequency Response:

 ± 0.5 dB, 20Hz–20kHz.

Input/Output Monitor Accuracy: 

Typically ±1dB.

Maximum Input Level:

 + 20 dBu. 

ADC Conversion:

 24 bit, 250 µs latency.

Содержание CTs 4200USP/CN

Страница 1: ...n this manual was deemed accurate as of the publication date However updates to this information may have occurred To obtain the latest version of this manual please visit the Crown website at www cro...

Страница 2: ...riesgo de un choque el ctrico El tri ngulo con el signo de admiraci n es usado para alertar al usuario de instrucciones importantes de operaci n o man tenimiento WATCH FOR THESE SYMBOLS IMPORTANT CTs...

Страница 3: ...e take the time to study this manual so that you can obtain the best possible service from your amplifier 1 1 Features Crown Switching Power Supply for reduced weight High power density with eight cha...

Страница 4: ...of the rack should be open Figure 2 2 illustrates standard amplifier airflow 2 Setup Figure 2 1 Dimensions Left CTs 4200USP CN Right CTs 8200USP CN Figure 2 2 Airflow 2 4 Front Panel Controls and Indi...

Страница 5: ...the Mode switch setting If this is not done the Bridge light will flash to indicate that the power must be cycled off and back on to reset the mode Q Cooling Vents Front to rear forced airflow 2 Setup...

Страница 6: ...or damage to the amplifier may result CAUTION Never use shielded cable for output wiring Figure 2 6 Balanced Input Connector Wiring See the Crown Amplifier Appli cation Guide available online at www...

Страница 7: ...be a stan dalone or separate network LAN Crown strongly recommends the use of a 100 Mb Ether net network for control and monitoring If network redundancy is required use a standard CAT5 cable to conn...

Страница 8: ...fic the indicator flashes The Link Activity LED flashes for all network traffic while the Data LED flashes only for commands addressed to this USP CN 3 2 5 CobraNet In Use Conductor Indicator The indi...

Страница 9: ...error never being detected THERMAL Errors can be generated for excessive temperature in the output section of the amplifier channel The Threshold Control sets the level that if exceeded will generate...

Страница 10: ...ng type system to continually drive the speaker allowing continuous mon itoring of the speaker load The following controls exist Sine On Off The sine wave signal generator s function Sine Frequency Co...

Страница 11: ...1 AUX Output Control of a Relay The AUX output has two enhanced modes Error Reporting and Flash Preset In Error Reporting mode the AUX port can be set up to change state when any selected error clip...

Страница 12: ...sult your electrician Models Under Voltage Limit Over Voltage Limit 100VAC 90VAC 110VAC 120 VAC units 108VAC 132VAC 220V 230V 240V units 198VAC 264VAC 4 2 6 Power Fuse A fuse protects the amplifier fr...

Страница 13: ...ve Note If the signal sounds distorted even though the Clip LED is off the input signal is distorted Check gain staging and output lev els of the mixer or preamp 5 Troubleshooting CONDITION No sound e...

Страница 14: ...r 10 Hz to 400 Hz 180 180 Crosstalk below rated power 20 Hz to 1 kHz 80 dB 80 dB Common Mode Rejection CMR 20 Hz to 1 kHz 50 dB 50 dB DC Output Offset Shorted input 5 mV 5 mV Input Impedance nominal b...

Страница 15: ...ons continued Figure 6 1 CTs 8200USP CN Typical Frequency Response 1 W Figure 6 2 CTs 8200USP CN Typical Phase Response 1 W Figure 6 3 CTs 8200USP CN Typical Damping Factor vs Frequency 6 Specificatio...

Страница 16: ...z CTs 8200USP CN MINIMUM GUARANTEED POWER In watts 0 1 THD 120VAC 60 Hz units 8 4 2 1 4 2 1 Constant Voltage full bandwidth power ratings support 100 Hz 20 kHz due to automatic high pass filters AC Po...

Страница 17: ...ntages over other non network communications platforms Figure 8 1 A Typical TCP IP Network The use of off the shelf networking hardware This technology makes use of network connectivity and hardware c...

Страница 18: ...Latency The transmitter and receiver buffering required for reliable transmission is selectable between 1 33 2 66 and 5 33 ms 64 128 and 256 samples 8 2 3 Bundles and Audio Channels You will be assig...

Страница 19: ...ice Shipping Instruc tions 1 Service Return Authorization SRA is required for product being sent to the factory for service Please complete the SRA by going to www crownaudio com support factserv htm...

Страница 20: ...service center or our factory within a reasonable time after receipt of the defec tive product at our authorized service center or our factory All expenses in remedying the defect including surface sh...

Страница 21: ...______________ State ___________________________ Zip Code ________________ Country __________________________ E mail address ___________________________________________ Phone include area code _______...

Страница 22: ..._________________ ___________________________________________________________________________________________________________________________________________________________________________ Other equi...

Страница 23: ......

Отзывы: