AC Power Draw and Thermal Dissipation:

Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Data based on all channels driven.

watts in

watts out

dissapated

Btu/hr

kcal/hr

At Idle (8.4 Ohm mode )

70

0

70

239

60

At Idle (70/100V mode)

114

0

114

389

98

1/8th Power Pink Noise

8 Ohms/Ch.

200x4

Typical of program material 

16 Ohms Bridge

400x2

just at clip.

4 Ohms/Ch.

260x4

8 Ohms Bridge

520x2

70V/Ch.

220x4

100V Bridge

220x2

1/3rd Power Pink Noise

8 Ohms/Ch.

200x4

Typical of program material

16 Ohms Bridge

400x2

with severe clipping.

4 Ohms/Ch.

260x4

8 Ohms Bridge

520x2

70V/Ch.

220x4

100V Bridge

220x2

382

1303

329

7.9

4.0

668

286

391

1336

337

11.8

5.9

1005

349

655

2236

564

7.6

3.8

648

257

318

1084

273

5.3

2.7

427

110

301

1027

259

7.8

3.9

639

134

505

1722

434

5.2

2.6

400

99

CTs 4200

Load

Rated 

Power

Line Current 

120VAC

Line Current 

230VAC

Watts 

Thermal Dissipation

8 AC Power Draw and 

Thermal Dissipation

Содержание CTs 4200

Страница 1: ...he information provided in this manual was deemed accurate as of the publication date However updates to this information may have occurred To obtain the latest version of this manual please visit the...

Страница 2: ...S S MBOLOS El tri ngulo con el s mbolo de rayo el ctrico es usado para alertar al usuario de el riesgo de un choque el ctrico El tri ngulo con el signo de admiraci n es usado para alertar al usuario d...

Страница 3: ...t Family Standard for Audio Video Audio Visual and Entertainment Lighting Control Apparatus for Professional Use Part 2 Immunity EN 61000 4 2 2003 Electrostatic Discharge Immunity Environment E2 Crite...

Страница 4: ...Thermal Level Control TLC 14 5 1 2 Fault 14 5 1 3 Fault Isolation Topology FIT 14 5 1 4 35 Hz High Pass Filter 14 5 1 5 AC Under Over Voltage Protection 14 5 1 6 Power Fuse 14 5 1 7 Inrush Limiting 14...

Страница 5: ...overloads and internal faults Proven Crown AB B Multi Mode output topology Continuously variable speed fans opti mize cooling efficiency Three Year No Fault Fully Transferable Warranty completely prot...

Страница 6: ...the Important Safety Instruc tions found at the beginning of this manual 3 2 InstallYour Amplifier CAUTION Before you begin make sure your amplifier is disconnected from the power source with the pow...

Страница 7: ...ew spacing is shown in Figure 3 5 To connect outputs first remove the touch proof cover plate covering the ter minal strip by removing the screw which holds it in place To prevent the possibility of s...

Страница 8: ...ction 5 2 2 for more information Typical input and output wiring along with level control and Mode Switch settings are shown in Figure 3 7 Make sure the Mode switch is set to the Dual 70V position INP...

Страница 9: ...itch while the amplifier power is on See Section 5 2 2 for more information Typical input and output wiring along with level control and Mode Switch settings are shown in Figure 3 9 Make sure the Mode...

Страница 10: ...ed mains frequency requirements indi cated on the amplifier s back panel label If you are unsure of the output voltage of your AC mains please consult your electrician Models Under Voltage Limit Over...

Страница 11: ...ch a config uration may result in premature clipping speaker damage or a blown power fuse Remember Crown is not liable for damage that results from overdriving other system compo nents 4 1 Precautions...

Страница 12: ...sig nal rises to a level typically considered as the onset of audible clipping The Clip Indicator also will illuminate during Ther mal Level Control TLC or input overload E Thermal Indicator Red LED o...

Страница 13: ...C8 module explained in Section 5 3 1 Control Modules N Channel Level Controls One 21 position detented rotary potentiometer per channel ranging from infinity 70 dB to 0 dB attenuation Refer to Section...

Страница 14: ...lue Power LED flashes The amplifier will turn back on when the AC line voltage returns to safe operating levels Figure 5 1 provides voltage limits for all amplifier AC voltage con figurations Also the...

Страница 15: ...vary 6 Detent 4 8 Ohm 70V 100V 0 full CCW 68 31 72 90 71 02 1 67 54 72 06 70 26 2 32 23 36 61 34 90 3 25 46 29 74 28 00 4 21 83 25 87 24 22 5 19 23 23 20 21 58 6 17 12 20 94 19 40 7 15 36 19 02 17 53...

Страница 16: ...to the respective VCA con nector on the VCA MC Refer to the VCA MC Operation Manual for wiring of the single or multiple channel level control Your amplifier may have come with a VCA MC module already...

Страница 17: ...the power supply Refer to section 5 1 6 for specific voltage requirements CONDITION Fault indicator is on POSSIBLE REASON The amplifier channel has stopped oper ating Return the unit to an authorized...

Страница 18: ...s one by one to determine if one of the loads is shorted 6 Troubleshooting CONDITION Thermal indicator is flashing POSSIBLE REASON The amplifier has become too hot for safe operation Check for loads l...

Страница 19: ...ts 8 4 2 1 4 2 1 Constant Voltage full bandwidth power ratings support 100 Hz 20 kHz due to automatic high pass filters Channels Driven 2 4 1 2 1 1 kHz 20 Hz 20 kHz 1 kHz 1 kHz 20 Hz 20 kHz 4 Ohm 260...

Страница 20: ...Note Safe with all types of loads Stereo Bridge Mono 4 8 and 25 ohms 70V 8 16 and 50 ohms 100V 4 8 and 25 ohms 70V 8 16 and 50 ohms 100V Voltage Gain at maximum level setting 1 4V sensitivity 4 8 Ohm...

Страница 21: ...CTs Power Amplifiers Operation Manual 7 Specifications Figure 7 3 CTs 8200 Typical Frequency Response 1 W Figure 7 4 CTs 8200 Typical Phase Response 1 W Figure 7 5 CTs 8200 Typical Damping Factor vs F...

Страница 22: ...Operation Manual CTs Power Amplifiers page 22 Figure 7 6 CTs 8200 Typical Output Impedance vs Frequency Figure 7 7 CTs 8200 Typical Crosstalk vs Frequency 7 Specifications...

Страница 23: ...th Power Pink Noise 8 Ohms Ch 200x4 Typical of program material 16 Ohms Bridge 400x2 just at clip 4 Ohms Ch 260x4 8 Ohms Bridge 520x2 70V Ch 220x4 100V Bridge 220x2 1 3rd Power Pink Noise 8 Ohms Ch 20...

Страница 24: ...wer Pink Noise 8 Ohms Ch 160x8 Typical of program material 16 Ohms Bridge 320x4 just at clip 4 Ohms Ch 200x8 8 Ohms Bridge 400x4 70V Ch 200x8 100V Bridge 200x4 1 3rd Power Pink Noise 8 Ohms Ch 160x8 T...

Страница 25: ...Authorization SRA is required for product being sent to the factory for service Please complete the SRA by going to www crownaudio com support factserv htm If you do not have access to our website cal...

Страница 26: ...oduct at our authorized service center or our factory All expenses in remedying the defect including surface shipping costs in the United States will be borne by us You must bear the expense of shippi...

Страница 27: ...hase price not including inter est insurance closing costs and other finance charges less a reasonable depreciation on the product from the date of original purchase War ranty work can only be perform...

Страница 28: ...Operation Manual CTs Power Amplifiers page 28 NOTES...

Страница 29: ...____________________ E mail address ___________________________________________ Phone include area code ___________________________ Fax __________________________________ MODEL SERIAL PURCHASE DATE e...

Страница 30: ...Operation Manual CTs Power Amplifiers page 30 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 31: ...__________________ Other equipment in your system ______________________________________________________________________________________________________________________________________________________...

Страница 32: ......

Отзывы: