SYMPTON
CAUSES
ACTION
WATER OVERFLOWING
WATER LEVEL TOO HIGH
Check and set water level to indicated
level 20mm below overflow pipe.
Remove ball valve insert.
Clean and reinstall and adjust ball valve
arm if necessary.
Remove ball float and check to make
sure there is no water in it. Replace if
necessary.
CONTINUOUS BOILING
BALL VALVE DEFECTIVE.
FAULTY ELEMENT
Ensure ball valve is closed off (does not
leak). Replace if necessary.
Replace element.
WATER NOT HOT
POWER NOT TURNED ON.
ELEMENT FAULTY
Check if power is ON.
Check the element is drawing the cor-
rect current. Replace if found to be
faulty.
NO WATER
WATER HAS BEEN TURNED OFF.
BLOCKED BALL VALVE.
BLOCKED FLOW TANK.
BLOCKED FILTER
Turn water ON.
Remove ball valve and clean out hole or
replace ball valve.
Clean out hole with piece of 3mm wire
that is situated at the bottom of the flow
tank.
Change filter cartridge.