TROUBLE SHOOTING 

ACTION ONLY TO BE PERFORMED BY A QUALIFIED PERSON 

CROWN INDUSTRIES 

F 47 / 70-72 Cave Hill Road, Lilydale,  Victoria  3140  

Tel. 61 3 9739 6966         AUSTRALIA         Fax 61 3 9739 6977 

  Website: www.crownindustries.com.au    

Email: [email protected] 

SYMPTON 

CAUSES 

 

ACTION 

WATER OVERFLOWING 

WATER LEVEL TOO HIGH 

Check and set water level to indicated 
level 20mm below overflow pipe.       
Remove ball valve insert.                     
Clean and reinstall and adjust ball valve 
arm if necessary.  

Remove ball float and check to make 
sure there is no water in it. Replace if 
necessary. 

CONTINUOUS BOILING 

BALL VALVE DEFECTIVE. 

 

FAULTY ELEMENT 

Ensure ball valve is closed off (does not 
leak). Replace if necessary.     

Replace element. 

WATER NOT HOT 

POWER NOT TURNED ON. 

ELEMENT FAULTY 

Check if power is  ON. 

Check the element is drawing the cor-
rect current. Replace if found to be 
faulty. 

NO WATER 

WATER HAS BEEN TURNED OFF.   

 

BLOCKED BALL VALVE. 

 

BLOCKED FLOW TANK. 

 

BLOCKED FILTER 

Turn water ON. 

 

Remove ball valve and clean out hole or 
replace ball valve. 

Clean out hole with piece of 3mm wire 
that is situated at the bottom of the flow 
tank. 

Change filter cartridge. 

 

Содержание CRN30

Страница 1: ...VICE COMPLYING WITH THE REQUIREMENT OF A S 3500 1 BE INSTALLED ON THE WATER SUPPLY INLET TO THIS UNIT Unit to be connected in accordance with A S 3500 A S 3000 PROUDLY MADE IN AUSTRALIA Boiling Water Units 30 40 50 60 litres Wall Mounted Optional Stainless Steel Cover Simple service if required No costly parts 1 year warranty Energy efficient Standard colour bond finish OPERATING INSTALLATION INST...

Страница 2: ...8 6 0 775 600 250 CRN60 60 300 200 260 4 8 6 0 840 600 250 DO NOT SWITCH ON POWER WITHOUT WATER RUNNING OUT FROM THE TAP POWER MUST BE OFF UNTIL INSTALLATION IS COMPLETE This unit is fitted with a computerised element and boil dry protection Maximum inlet pressure 820 kpa Fit PLV if required Minimum inlet pressure 200 kpa If a lower pressure is encountered refer to manufacturer DO NOT PLUG IN POWE...

Страница 3: ... area where water can be disposed of in a safe manner 5 Plug unit into 10 amp power outlet If installing larger 3 6kw element model be sure that lead and plug is 15amp The same as power outlet 6 Turn ON water supply to unit and OPEN the outlet tap 7 Wait until water flows out of the tap 8 When water flows out of the tap please SWITCH THE POWER ON BEFORE USING WE RECOMMEND THE FITTING OF A TRIPPLE ...

Страница 4: ...f necessary Remove ball float and check to make sure there is no water in it Replace if necessary CONTINUOUS BOILING BALL VALVE DEFECTIVE FAULTY ELEMENT Ensure ball valve is closed off does not leak Replace if necessary Replace element WATER NOT HOT POWER NOT TURNED ON ELEMENT FAULTY Check if power is ON Check the element is drawing the cor rect current Replace if found to be faulty NO WATER WATER...

Отзывы: