Crown CRN30 Скачать руководство пользователя страница 3

DO NOT PLUG IN OR TURN ON POWER 

1. 

Fit tap on to the outlet connection provided. 

2. 

Mount unit on wall using fixing points on the back of the unit. It is advisable to position the tap outlet over a drain 
board, so that in the event of a leaking tap the water can be disposed via the sink. 

3. 

Connect cold water supply to inlet (12mm) through a stop tap in the supply line. (stop tap to be provided by installer) 

4. 

Connect the overflow pipe to waste or any other area where water can be disposed of in a safe manner. 

5. 

Plug unit into 10 amp power outlet. *If installing larger 3.6kw element model, be  sure that lead and plug is 15amp. 
The same as power outlet. 

6. 

Turn “ON” water supply to unit  and “OPEN” the outlet tap. 

7. 

Wait until water flows out of the tap. 

8. 

When water flows out of the tap please SWITCH THE POWER ON. 

BEFORE USING: 

WE RECOMMEND THE FITTING OF A TRIPPLE ACTION FILTER. 

ONLY TEFLON TAPE TO BE USED WHERE NECESSARY. 

UNDER NO CIRCUMSTANCES IS PLUMBERS PASTE TO BE USED. 

DO NOT CONNECT TO HOT WATER LINE— TO DO SO WILL VOID WARRANTY. 

AFTER POWER IS ON — ALLOW 45 MINUTES BEFORE USING 

  

UNIT MUST BE POSITIVELY EARTHED 

Содержание CRN30

Страница 1: ...VICE COMPLYING WITH THE REQUIREMENT OF A S 3500 1 BE INSTALLED ON THE WATER SUPPLY INLET TO THIS UNIT Unit to be connected in accordance with A S 3500 A S 3000 PROUDLY MADE IN AUSTRALIA Boiling Water Units 30 40 50 60 litres Wall Mounted Optional Stainless Steel Cover Simple service if required No costly parts 1 year warranty Energy efficient Standard colour bond finish OPERATING INSTALLATION INST...

Страница 2: ...8 6 0 775 600 250 CRN60 60 300 200 260 4 8 6 0 840 600 250 DO NOT SWITCH ON POWER WITHOUT WATER RUNNING OUT FROM THE TAP POWER MUST BE OFF UNTIL INSTALLATION IS COMPLETE This unit is fitted with a computerised element and boil dry protection Maximum inlet pressure 820 kpa Fit PLV if required Minimum inlet pressure 200 kpa If a lower pressure is encountered refer to manufacturer DO NOT PLUG IN POWE...

Страница 3: ... area where water can be disposed of in a safe manner 5 Plug unit into 10 amp power outlet If installing larger 3 6kw element model be sure that lead and plug is 15amp The same as power outlet 6 Turn ON water supply to unit and OPEN the outlet tap 7 Wait until water flows out of the tap 8 When water flows out of the tap please SWITCH THE POWER ON BEFORE USING WE RECOMMEND THE FITTING OF A TRIPPLE ...

Страница 4: ...f necessary Remove ball float and check to make sure there is no water in it Replace if necessary CONTINUOUS BOILING BALL VALVE DEFECTIVE FAULTY ELEMENT Ensure ball valve is closed off does not leak Replace if necessary Replace element WATER NOT HOT POWER NOT TURNED ON ELEMENT FAULTY Check if power is ON Check the element is drawing the cor rect current Replace if found to be faulty NO WATER WATER...

Отзывы: