1.  INTRODUCTION

A.  PURPOSE:

  This Crown Installation, Operation, 

Maintenance and Parts Manual has been developed to 

assist you in the installation, operation and maintenance 

of your electric operator and thus enable you to utilize it 

to its maximum efficiency.

B.  MODELS COVERED:  

The manual covers current 

models 1502-1 & 1502-2 Operators. 

C.  APPLICATION:

  The Crown Industrial Model #1502 

Swing Door Operators are intended for use on large 

interior industrial doors operated by trained personnel.

D.  DESCRIPTION:  

The model 1502 operator consists of a 90 volt, DC 

permanent magnet gear motor, variable torque electric 

clutch, right angle worm gear and internal limit switches. 

The motor control is accomplished by means of an 

electronic control package.  The motor controls are 

mounted in a remotely located control panel.  The 

operator shall mount above the door on the lintel of the 

frame.  Door connecting arms and door brackets are 

included. The operator mounting frame and cover shall 

be prime coated ready for finish painting in the field.  The 

supply voltage should be 120 volt AC, single phase. The 

control circuit will allow for two speed operation with the 

run and creep speeds independently adjustable. 

Figure 1.  1502 Left Hand Swing Door 

Operator

2.  INSTALLATION AND OPERATION

A.   GENERAL

The Crown 1502 Electric Door Operator has been 

designed primarily for commercial and industrial 

installations where the operator has to withstand 

constant hard use.  To ensure correct installation 

and proper operation of the operator and associated 

hardware, the following instructions are given:

(1) SHIPMENT CHECK:  Included with the installation 

packet is a copy of the packing slip for the components 

supplied with the order.  Compare the components 

received with the packing slip to insure that all 

equipment is complete.

(2) REVIEW INSTALLATION DRAWINGS:  The 

installation drawings show the layout of the door, 

template drilling for the door and jamb, and general 

terms used to describe the components.  Review the 

drawings to familiarize yourself with the equipment.

(3) CHECK THE DOORS:  Prior to installing the 

operator, confirm the doors are properly hung.  95% of 

all door operator trouble is caused by doors not swinging 

free of the floor and lintel.  It is also very important that 

all hinge pins are properly aligned and there is no hinge 

binding.

(4) PREPARING THE DOOR AND LINTEL:  

The door operators are handed (left and right) and 

are supplied as push or pull to open (Refer to Figure 2 

Operator Handing).  Ensure proper backing and support 

are available in the lintel and the door to receive the 

operator and connecting arm.  Remove the electric 

operator from crate.  Choose the appropriate drilling 

template.  Prepare the lintel for the operator.

Figure 2. Operator Handing

RIGHT HAND PULL TO OPEN

#1502 OPERATOR

#1502 OPERATOR

LEFT HAND PULL TO OPEN

HINGE

#1502 OPERATOR

#1502 OPERATOR

RIGHT HAND PUSH TO OPEN

LEFT HAND PUSH TO OPEN

HINGE

Crown Industrial Operators • 213 Michelle Ct. • So. San Francisco, Ca 94080-6202 

Phone: (650) 952-5150 • Fax: (650) 873-1495

www.crown-industrial.com Email: [email protected]

G-1001

1

Crown Industrial Operators • 213 Michelle Ct. • So. San Francisco, Ca 94080-6202 

Phone: (650) 952-5150 • Fax: (650) 873-1495

www.crown-industrial.com Email: [email protected]

Crown Industrial Operators • 213 Michelle Ct. • So. San Francisco, Ca 94080-6202 

Phone: (650) 952-5150 • Fax: (650) 873-1495

www.crown-industrial.com Email: [email protected]

Содержание Aut-o-doR 1502-1

Страница 1: ...o San Francisco CA 94080 Phone 650 952 5150 Fax 650 873 1495 website www crown industrial com Copyright Crown Industrial Operators 2011 GENERAL INSTALLATION OPERATION MAINTENANCE and PARTS MANUAL for...

Страница 2: ...cement Parts 6 B Parts List 6 7 WARRANTY 11 Note We reserve the right to modify or change without prior notice any statements or information contained herein If exact dimensions or specifications are...

Страница 3: ...allation packet is a copy of the packing slip for the components supplied with the order Compare the components received with the packing slip to insure that all equipment is complete 2 REVIEW INSTALL...

Страница 4: ...tor Assembly The angle bracket is mounted to the face of the door with fasteners while the other end mounts directly to the operator drive shaft Note For push to open applications the operator is moun...

Страница 5: ...hand push to open operators a LSO Limit Switch Open Wired Normally Closed This limit shuts off the electric operator when the door reaches the full open position Light on PLC turns OFF when activated...

Страница 6: ...extended can engage the limit switch roller Adjust the limit switch by turning the limit switch adjusting screw until half of the extended cam travels past the roller When this limit switch roller is...

Страница 7: ...til the door begins to move For each adjustment be sure to stand clear of the door 7 Reset the run and creep speed pots in the control box to a combined equivalent speed ASP as fied in the table on Sa...

Страница 8: ...son or company to whom the invoices to be sent B PARTS LIST The following pages list the replacement parts which are illustrated in page 7 Part Number Description 1502P27 Electric Magnetic Clutch Asse...

Страница 9: ...Pkg and Pull to Open Accessory Pkg are not shown 1502P37 Limit Switch 4 1 Adjustment Screws for Limit Switch Cams Operator Name Plate Indicates Model 1502 Serial 1502 Operator without Cover 1502 Opera...

Страница 10: ...ORTH ABOVE Operator Serial Number ________________________________ H P _____________________________________ Supplied on Crown Industrial Operators Order Number _______________________________________...