INSTALLATION AND OPERATION MANUAL, ELECTRIC SELF GENERATING SINGLE AND
TWIN STEAM MIXER KETTLE, MODELS ELTM-40 TO 100 AND ELTM 40-2 TO 100-2
Part No. 10041R4
24
2018-08-08
7.0 TROUBLESHOOTING
KETTLE
LOW WATER LEVEL
Proper water level must be maintained within the jacket for the kettle to operate. Depletion
of water may occur from excessive opening of or leakage through the safety relief valve.
If water is below required operating level, either initially at start-up or during use, the kettle
will automatically shut off and the LOW WATER signal light will come on.
In order for the kettle to operate, the following procedure must be followed:
The kettle must be cool before proceeding with the following steps.
Trip the safety relief valve lever to relieve all pressure from the kettle jacket.
At exterior rear of kettle jacket remove nut from Air Vent.
Insert funnel into Air Vent opening and slowly add the indicated amount of clean water for:
PER KETTLE
PER KETTLE
MODEL
ADD:
IF COMPLETELY EMPTY, ADD:
ELTM-40 (-2)
220 ounces
6.50 litres
548 ounces
16.20 litres
ELTM-60 (-2)
250 ounces
7.39 litres
586 ounces
17.33 litres
ELTM-80 (-2)
340 ounces
10.05 litres
850 ounces
25.12 litres
ELTM-100 (-2)
420 ounces
12.42 litres
1088 ounces
32.17 litres
Replace air vent nut.
Follow AIR VENTING INSTRUCTIONS.
Continue normal operating procedure of kettle.