![Crown Food Service Equipment ELTM-100 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/crown-food-service-equipment/eltm-100/eltm-100_installation-and-operation-manual_2690676021.webp)
INSTALLATION AND OPERATION MANUAL, ELECTRIC SELF GENERATING SINGLE AND
TWIN STEAM MIXER KETTLE, MODELS ELTM-40 TO 100 AND ELTM 40-2 TO 100-2
Part No. 10041R4
21
2018-08-08
6.0 MAINTENANCE
(Continued)
SETTING UP HYDRAULIC SYSTEM FOR MIXING KETTLES
A. SETTING MIXER SYSTEM PRESSURE
1.
On the operator panel, switch “POWER”
to on, “MIXER” to on, and set mixer
speed to “STOP”.
2.
Turn trim relief stem, item “B”, completely in.
3.
Increase the pump pressure by turning “A”
inwards, until gauge “D" reads 1700 psi. The
pressure must be 300 psi higher than the
pump setting.
4.
Adjust trim relief “B” outwards until pressure
indicated on gauge “D" begins to drop.
5.
Lock the trim relief “B”.
6.
Decrease the pump pressure by turning
“A” outwards, until gauge “D" reads 1400 psi
and lock in place.
Figure 2