35
35
Main
burners
light?
24 volts
across
B1
&
B2
?
Refer to ignition system
troubleshooting chart
(page 38).
*
Defective damper
*
Defective L8148E
*
Defective damper
harness
*
Loose damper
harness connection
*
Obstruction in path
of damper blade
24 volts across
standing pilot gas
valve terminals or
terminals
5
&
6
on
S8600 module?
24 volts
across spill
switch?
*
Chimney blockage
*
Chimney system not
constructed in accordance
with Parts 7 and 10 of
National Fuel Gas Code
.
*
Down draft
*
Inadequate combustion air
supply in boiler room
Y
N
N
Y
Y
24 volts
across
rollout
switch?
*
Loose electrical
connection in 24
volt wiring
between
B1
or
B2
and gas valve or
module
*
Rollout switch open.
Replace with exact
replacement (see parts
list). Check for blocked
heat exchanger.
Y
N
N
Y
N
Do burner and
circulator shut
down at end of
call for heat?
END
Pull wire off of
T
terminal on
aquastat. Does
boiler shut down?
*
T'stat or
zone valve
wiring calling
for heat
*
T'stat wires
shorted
*
Internal boiler
wiring
problem,
consult Crown
representative
Do burners
shut down before
gage temp
exceeds high limit
s15F?
*
Defective
L8148A
*
Sensing bulb not
bottomed out in
well
N
Y
Y
N
N
Y
Содержание CWI103
Страница 2: ......
Страница 17: ...15 15 FIGURE 12 INDIRECT WATER HEATER BOILER SIDE PIPING FIGURE 11 STANDARD BOILER PIPING ...
Страница 19: ...17 17 FIGURE 15 BOILER PIPING WITH CHILLER FIGURE 14 ISOLATION OF BOILER FROM SYSTEM WITH A HEAT EXCHANGER ...
Страница 29: ...27 27 FIGURE 24a GAS VALVE DETAIL HONEYWELL VR8204 AND VR8304 FIGURE 24b GAS VALVE DETAIL ROBERTSHAW 7000DERHC ...
Страница 34: ...32 32 Notes ...
Страница 41: ...39 39 Notes ...
Страница 43: ...41 41 ...
Страница 45: ...43 43 ...
Страница 47: ...45 45 ...
Страница 49: ...47 47 FIGURE A1 BASE HEAT EXCHANGER FLUE COLLECTOR ASSEMBLY ...
Страница 51: ...49 49 FIGURE A2 JACKET INSTALLATION ...
Страница 53: ...51 51 FIGURE A3 TAPPING LOCATIONS SEE TEXT FOR TAPPING USES ...
Страница 54: ...52 52 Notes ...
Страница 55: ...53 53 Notes ...