background image

Only qualified service personnel shall perform installation and service.

 

 

 

5

3.  Reconnect the three (3) furnace wiring harness leads to the terminal block 

located on the blower scroll. For all furnace models: 

 

• 

Connect the red wire (cooling fan speed) to the terminal block labeled “H”.  

• 

Temporarily, connect the orange wire (heating fan speed) to the terminal 
block labeled “L”. 

• 

Connect the white wire to the terminal block labeled “C”. 

  
Refer to “Supply / Return Airflow and Air Temperature” section of the Crown 
Oil-Fired Central Furnace Installation, Operation, and Service Manual with 
Users Information Section for a procedure to select the heating fan speed. 

 

4.  Replace the blower access panel. 
 
5.  Restore electrical power to the furnace at the disconnecting switch and set 

the room thermostat operating mode to “ON”. 

 

6.  Adjust the room thermostat to cause the furnace to operate through at least 

one (1) complete heating or cooling cycle to test operation of the blower. 
Setting the thermostat to the “FAN” or “FAN ON” position should cause the 
blower to run continuously on high speed. 

 

7.  The blower should accelerate from rest to full speed within about ten (10) 

seconds, or less. Blower operation should be smooth without clattering or 
rattling noises. If blower operation generates unusual noises, check for loose 
fasteners and parts in the furnace. Remove, tighten, or secure all loose parts. 
Blower pulsation (sometimes called “hunting”) usually indicates the duct 
system is too restrictive. Also, consult the furnace instruction manual for 
blower troubleshooting steps. 

 

8.  Package the standard blower / motor assembly in the shipping carton for the 

upgrade blower / motor assembly. Contact your dealer or distributor regarding 
the possibility of returning the standard blower / motor assembly for credit 
against your account. 

 
 

 
 

 

Содержание CHB68-112

Страница 1: ...if you find an oil leak DO NOT try to operate this appliance If possible close the manual fuel shutoff valve on the oil supply tank Immediately call your oil supplier Follow the oil supplier s instructions If you cannot reach your oil supplier call the fire department A qualified installer service agency or the oil supplier must perform installation and service These instructions should be read pr...

Страница 2: ...Blower Motor Assembly WARNING If the heating system was recently operating allow the furnace to cool to room temperature before proceeding with disassembly WARNING BEFORE disconnecting the furnace wiring harness at the blower terminal block use a voltmeter or equivalent device to measure the electrical potential across the red and white wires and the orange and white wires at the terminal block No...

Страница 3: ...nel Then remove two 2 sheet metal screws located about seven 7 inches back from the front surface of the furnace driven downward through the blower support panel and into the support angles refer to Figure 1 Show depiction here of highboy blower compartment blower assy retaining screws and mounting angles and rails ID components Figure 1 Blower Assembly Retaining Screw Locations on the Highboy Oil...

Страница 4: ...tat ID components Figure 3 Blower Assembly Retaining Screw Locations on the Horizontal Counterflow Oil Furnace 5 Remove the entire blower motor assembly from the furnace Set it aside On highboy models pull forward and slide the blower out of the furnace On lowboy models lift up slightly and pull the blower out of the rear of the furnace o On horizontal counterflow models lift and pull the blower o...

Страница 5: ...counterflow models set the blower down in the furnace and center it over the blower support panel opening 2 Reinstall the fasteners fixing the blower mounting angles or legs in place On highboy models align the holes in the support angles with the holes in the blower support panel Drive two 2 sheet metal screws downward through the blower support panel holes and into the holes in the support angle...

Страница 6: ... ON 6 Adjust the room thermostat to cause the furnace to operate through at least one 1 complete heating or cooling cycle to test operation of the blower Setting the thermostat to the FAN or FAN ON position should cause the blower to run continuously on high speed 7 The blower should accelerate from rest to full speed within about ten 10 seconds or less Blower operation should be smooth without cl...

Отзывы: