A.  This appliance has a pilot which must be
      lighted by hand.  When lighting the pilot, follow
      these instructions exactly.

B.  BEFORE LIGHTING smell all around the
     appliance area for gas.  Be sure to smell next
     to the floor because some gas is heavier than
     air and will settle on the floor.

     WHAT TO DO IF YOU SMELL GAS
             Do not try to light any appliance.
             Do not touch any electric switch;  do not
             use any phone in your building.
             Immediately call your gas supplier from 
             a neighbor’s phone.  Follow the gas
             supplier’s instructions.

             If you cannot reach your gas supplier, call
             the fire department.

C.  Use only your hand to push in or turn the gas
     control knob.  Never use tools.  If the knob will
     not push in or turn by hand, don’t try to repair it,
     call a qualified service technician.  Force or
     attempted repair may result in a fire or explosion.

D.  Do not use this appliance if any part has been
     under water.  Immediately call a qualified service
     technician to inspect the appliance and to 
     replace any part of the control system and any
     gas control which has been under water.
            

LIGHTING INSTRUCTIONS

1.  STOP!  Read the safety information above on 

     this label.

2.  Set the thermostat to lowest setting.

3.  Turn off all electric power to the appliance.

4.  Remove front access panel.

5.  Rotate the gas control knob clockwise          to OFF.

 8.  Turn Knob on gas control counterclockwise
      to “PILOT”.

 9.  Push down and hold the Knob while
      you light pilot burner with a match.
      After about one minute, release reset button. 
      Pilot should remain lit.  If it goes out, turn gas
      control knob clockwise          to OFF.  To relight,
      repeat steps 5-9.
           If button does not pop up when released, stop
           and immediately call your service technician
           or gas supplier.
           If the pilot will not stay lit after several tries,
           turn the gas control knob to “OFF” and call
           your service technician or gas supplier.

10.  After pilot remains lit when red reset button is
       released, turn gas control knob counterclockwise
                  to ON.

11.  Replace front access panel.

12.  Turn on all electric power to the appliance.

13.  Set thermostat to desired setting.

1.  Set the thermostat to lowest setting.

2.  Turn off all electric power to the appliance if
     service is to be performed.

3.  Push in gas control knob slightly and turn
     clockwise          to “OFF”.  Do not Force.

WARNING:  If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

6.  Wait five (5) minutes to clear out any gas.  Then
     smell for gas, including near the floor.  If you then
     smell gas, STOP!  Follow “B” in the safety inform-
     ation above on this label.  If you don’t smell gas,
     go to the next step.

7.  Find pilot - follow metal pilot
     tube from gas control to 
     pilot burner.

PILOT
BURNER

THERMO-
COUPLE

TO TURN OFF GAS TO APPLIANCE

FOR YOUR SAFETY READ BEFORE LIGHTING

GAS

INLET

GAS CONTROL KNOB

SHOWN IN "OFF" POSITION

POSITION

INDICATOR

PILOT

ON

OFF

LIGHTING INSTRUCTIONS FOR BOILERS EQUIPPED WITH ROBERTSHAW

7000ERHC SERIES GAS VALVES (STANDING PILOT)

Содержание BERMUDA BSI069

Страница 1: ...ffixed on or adjacent to the boiler WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or loss of life For assistance or additional informa tio...

Страница 2: ...AppendixA Knockdown BoilerAssembly 47 I Product Description The BSI series boilers are low pressure cast iron gas fired steam boilers designed for use in closed steam heating systems These boilers are...

Страница 3: ...URATION Combustion efficiency Volume to normal water line NOTE BSI345 and BSI379 not available for use with LP gas Suffix E Intermittent Ignition Suffix S Standing Pilot Add Suffix N for Natural Gas o...

Страница 4: ...for the correct gas natural or LP The BSI345 and BSI379 may only be used with natural gas 5 Boilers installed at altitudes above 2000 ft require different burners and main burner orifice than those at...

Страница 5: ...Air for Combustion and Ventilation of the National Fuel Gas Code NFPA 54 ANSI Z223 1 To ensure an adequate supply of combustion ventilation and flue gas dilution air supply start by determining wheth...

Страница 6: ...square inch per 1000 BTU hr input of all gas burning appliances in the boiler room The minimum opening dimension is 3 inches Minimum opening free area is 100 square inches per opening If the total vo...

Страница 7: ...7 6 FIGURE4 ALLAIRFROMOUTDOORS VENTILATED CRAWL SPACE AND ATTIC FIGURE5 ALLAIRFROMOUTDOORS VIA VENTILATED ATTIC FIGURE3 BOILERINSTALLEDINCONFINEDSPACE ALL AIR FROM INSIDE...

Страница 8: ...8 FIGURE6 ALLAIRFROMOUTDOORS USING OPENINGSINTOBOILERROOM FIGURE7 ALLAIRFROMOUTDOORS USING HORIZONTAL DUCTS INTO BOILER ROOM 7...

Страница 9: ...n exterior chimneys may be used An exterior masonry chimney may be used if it is lined with B vent or a listed chimney lining system 5 This boiler may be vented using a listed power venter The power v...

Страница 10: ...d with each appliance remaining connected to the common venting system placed in operation while the other appliances remaining connected to the common venting system are not in operation a Seal any u...

Страница 11: ...11 10 FIGURE8 BSI BOILERTYPICALVENTSYSTEM INSTALLATION AND COMPONENTS FIGURE 9 VENTDAMPERINSTALLATIONDETAILS RIGHT SIDE VIEW...

Страница 12: ...ows typical gas piping connection to the BSI boiler A sediment trap must be installed upstream of all gas controls Install a manual shut off valve outside the jacket and ground joint union as shown Th...

Страница 13: ...n Figure 12 and appears to be working If two or more steam mains must be connected to the boiler connect a separate take off for each main into the header between the riser s and equalizer Also note t...

Страница 14: ...area where it is not likely to become plugged by debris or subjected to freezing 4 Install drain valve into tapping on boiler left side using the 2 x 3 4 bushing provided see Figure 1 5 Connect system...

Страница 15: ...ERPIPINGMISTAKES FIGURE11 STEAMBOILERPIPINGFORGRAVITYRETURN A B C D BSI069 2 1 1 2 1 1 4 BSI103 2 1 1 2 1 1 4 BSI138 2 1 1 2 1 1 4 BSI172 2 1 1 2 1 1 4 BSI207 2 3 1 1 2 1 1 4 BSI241 2 3 2 1 1 2 BSI276...

Страница 16: ...on 2 Y Strainer Install a Y strainer to prevent sediment from accumulating inside the indirect water heater 3 Check Valve Prevents gravity circulation through the indirect water heater when the boiler...

Страница 17: ...WIRE feeder Do not alter factory boiler wiring Connect VXT 24 to CG400Aas follows Connect the BLACK lead on the feeder to terminal A on the LWCO Connect the WHITE lead on the feeder to terminal 2 on t...

Страница 18: ...igh limit described in Part IX must also be supplied by the installer Acall for heat from the indirect water heater thermostat will energize the relay making both sets of contacts One set of these con...

Страница 19: ...GURE14b WIRINGMCDONNELL MILLERWF2 U 24FEEDERORTHREE WIREHYDROLEVEL VXT 24FEEDERTOBOILEREQUIPPEDWITH 67L W C O CAUTION DO NOT INSTALL JUMPER BETWEEN 2 3 ON 67 L W C O FIGURE15 WIRINGINDIRECTWATERHEATER...

Страница 20: ...in gas flow through the control and burner operation Sequence of Operation Intermittent Ignition 1 When the boiler is energized 24 volts is immediately applied to terminals 1 blue and 4 yellow on the...

Страница 21: ...WIRINGDIAGRAM STANDINGPILOTANDMcDONNELL MILLERMODEL67LOWWATERCUTOFF L N V8295A BSI310 379 ONLY VENT DAMPER NOTE 2 NOTE 3 LESS VENT DAMPER 2 VENT DAMPER REQUIRED ON BSI069 BSI276 OPTIONAL ON BSI310 BSI...

Страница 22: ...er cut off interrupts burner operation McDonnell Miller 67 Low Water Cut off Interrupts burner operation if the water in the boiler drops below a safe level Burner operation is restored when the water...

Страница 23: ...terrupts burner operation when flames or excessive heat are present in vestibule The flame roll out switch is a single use device which must be replaced by an identical switch in order to restore norm...

Страница 24: ...should produce single steady medium blue flame covering around 3 8 to of thermocouple tip See Figure 21 for intermittent ignition Pilot burner produces three flames The center one should be a steady m...

Страница 25: ...manometer to the manifold outlet pressure tap on the gas valve see Figures 23 and 24 d Read the manifold pressure It should be set at NaturalGas LPGas Manifold Press inches w c 3 5 10 0 e If a manifol...

Страница 26: ...you light pilot burner with a match After about one minute release reset button Pilot should remain lit If it goes out turn gas control knob clockwise to OFF To relight repeat steps 5 9 If button does...

Страница 27: ...old the Knob while you light pilot burner with a match After about one minute release reset button Pilot should remain lit If it goes out turn gas control knob clockwise to OFF To relight repeat steps...

Страница 28: ...all electric power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the pilot Do try to light the pilot by hand not 5 Remove front access panel 6 Rotat...

Страница 29: ...lowest setting 3 Turn off all electric power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the pilot Do try to light the pilot by hand not 5 Remove f...

Страница 30: ...ler models should relight 20 After the boiler has operated for approximately 30 minutes check the boiler and heating system piping for leaks Repair any leaks found at once 21 Inspect the vent system f...

Страница 31: ...204ANDVR8304 INTERMITTENT IGNITION FIGURE 23a GASVALVEDETAIL HONEYWELLVR8200ORVR8300 STANDINGPILOT FIGURE 23b GASVALVEDETAIL ROBERTSHAW 7000ERHCANDHONEYWELLV8295 STANDINGPILOT FIGURE 24b GASVALVEDETAI...

Страница 32: ...ck the thermocouple for deterioration some discoloration of the thermocouple is normal If any deterioration is present replace the thermocouple Inspect the pilot assembly for deposits and deterioratio...

Страница 33: ...s present in the steam main takeoff close it Alternatively temporarily replace enough of the vents on the mains and or radiators with plugs so that 2 5 psi can be developed when the boiler is fired d...

Страница 34: ...llector 14 Reattach all the jacket components 15 Reinstall burners being careful to put the pilot main burner in its original location 16 Replace the blocked vent switch 17 Reconnect the damper and ve...

Страница 35: ...s assume that the vent damper is closed at the beginning of the troubleshooting process With the 120 volts applied to the boiler and no call for heat the damper should go to the closed position If it...

Страница 36: ...hermostat Thermostat misw ired or misapplied N N 24 volts between P2 and 2 on CG400 LWCO Jumper missing betw een 1 and P1 on CG400 Poor connection betw een transformer and terminals 1 2 on CG400 24 vo...

Страница 37: ...ational Fuel Gas Code Down draft Inadequate combustion air supply in boiler room Y N Y 24 volts across rollout switch Loose electrical connection in spill switch or rollout switch wiring or gas valve...

Страница 38: ...ve transformer See Note 6 on page 34 N Y Bad connection in thermostat w iring Defective thermostat Thermostat misw ired or misapplied N N 24 volts betw een terminal 1 on 67 LWCO and yellow tranformer...

Страница 39: ...onal Fuel Gas Code Down draft Inadequate combustion air supply in boiler room Y N Y 24 volts across rollout switch Loose electrical connection in spill switch or rollout switch wiring or gas valve com...

Страница 40: ...orifice partially plugged Y N N Y N Turn control on gas valve to ON Y END Defective gas valve Y START 24 VOLTS PRESENT ACROSS TH AND TR ON GAS VALVE BUT MAIN BURNERS DO NOT LIGHT Ensure knob on gas v...

Страница 41: ...rcelain cracked Pilot flame not covering gap between electrode and grounding strap Low gas pressure at gas valve inlet Defective S8600 module Main burner lights N Y 24VAC across terminals 1 2 on S8600...

Страница 42: ...rown distributor consult the area Crown representative or the factory at Crown Boiler Co Customer Service P O Box14818 Philadelphia PA 19134 www crownboiler com For boilers installed at elevations abo...

Страница 43: ...43 42...

Страница 44: ...36 3501136 3501136 3501136 48 PILOT TUBING 1 ea 90 042 90 042 90 042 90 043 90 043 90 043 900041 900041 900041 49 35 1600 392449 50 35 1650 392449 4 51 51 51a 51 51a 61 40mm BURNER LESS PILOT BRACKET...

Страница 45: ...45 44...

Страница 46: ...FLOAT TYPE L W C O 67 CR 2 400676 1 ea 1 ea 1 ea 1 ea 1 ea 1 ea 1 ea 1 ea 1 ea 1 ea 90a PROBE TYPE L W C O CG400 400821 1 ea 1 ea 1 ea 1 ea 1 ea 1 ea 1 ea 1 ea 1 ea 1 ea 91 PRESSURE GUAGE 95 070 1 ea...

Страница 47: ...47 46...

Страница 48: ...2 Once the heat exchanger has been placed on the base inspect the gasket for proper seal Repair or replace gasket if necessary 3 Secure the heat exchanger with 5 16 lock nuts with nylon inserts and wa...

Страница 49: ...49 48 FIGUREA1 BASE HEATEXCHANGER FLUE COLLECTORASSEMBLY...

Страница 50: ...g pilot boilers only E ControlandTrimInstallation Refer to Figure A3 for Tapping Locations 1 Install the pressure limit control into tapping H with the siphon A x bushing has been factory installed Do...

Страница 51: ...51 50 FIGUREA2 JACKETINSTALLATION...

Страница 52: ...8 Hydrolevel CG 400 Probe Low Water Cutoff a Mount the end of the BX cable containing the 3 wire Molex plug and the single red wire to the control box with the BX cable fitting nut supplied b Insert t...

Страница 53: ...53 52 FIGUREA3 TAPPING LOCATIONS SEE TEXT FOR TAPPING USES...

Страница 54: ...54 Manufacturer of Hydronic Heating Products P O Box 14818 3633 I Street Philadelphia PA 19134 7HO D ZZZ FURZQERLOHU FRP P N980423 10 10Rev 3...

Отзывы: