background image

 

13

 

 

14

 

 

15

 

LED ENABLE/DISABLE SETTING -  
JUMPER “JP3” (FIG.4)

 

Position On (right) 

- LED ENABLE 

The RED LED will activate when the SRDT-15 
 Is in alarm condition. 

Position Off (left) 

- LED DISABLE 

The LEDS are disabled.

 

Note:

 the state of the Jumper “JP3” does not 

affect the operation of the relay. 
When an intrusion is detected, the LED will 
activate and the alarm relay will switch into alarm 
condition for 1.6 sec. 
 

LED

 

INDICATORS (Fig.4) 

YELLOW  LED - MW detection’s 
GREEN    LED - PIR detection’s 
RED         LED - Alarm 
 

 

 

TEST PROCEDURES

Wait one-minute warm-up

 

time after applying  

12 Vdc power. Conduct testing with the protected 
area cleared of all people. 

 Walk test

 

1.  Remove front cover.                                             

Set LED to ON position. 

2.  Reassemble the front cover. 
3.  Start walking slowly across the detection zone. 
4.  Observe that the red LED lights whenever 

motion is detected. 

5.  Allow 5 sec. between each test for the detector 

to stabilize. 

6.  After the walk test is completed, you can set the 

LED to OFF position. 

NOTE:

  

Walk tests should be conducted, at least once a 
year, to confirm proper operation and coverage of 
the detector. 

 

 

FIG. 5 - WA PIR + MW DETECTION 
PATTERN 

30m

0m

18m

5m

10m

15m

WA lens pattern 105 ° (PIR)

MW  pattern 

5m

10m

15m

30m

18m

10m

5m

         SIDE VIEW

TOP VIEW

 

16

 

 

17

 

 

18

 

 

FIG. 6 - LONG RANGE CURTAIN LENS 

 

0

5m

(16.4ft)

5m

(16.4ft)

0

5m

(16.4ft)

10m

(32.8ft)

15m

(49.2ft)

20m

(65.6ft)

25m

(82ft)

30m

(98.4ft)

TOP VIEW

SIDE VIEW

2.1m

(6.9ft)

0

5m

(16.4ft)

10m

(32.8ft)

15m

(49.2ft)

20m

(65.6ft)

25m

(82ft)

30m

(98.4ft)

3m

(9.9ft)

 

 

PATTERN SCALE CALIBRATION 

To calibrate the MW pattern scale, You need the 
size of the room (length and detection angle). 

For Doppler pattern see fig.7 and table1 on  
Page 18, where H – Doppler pattern max; 
                         ## - zone number;   
                          a – angle;  
                          X,Y – appropriate coordinates of    
Doppler pattern. 

The potentiometer RV1(Fig. 4) adjusts the 
detection pattern scale between 30% and 100% 
(factory set to 70%). Rotate the potentiometer 
clockwise to increase pattern scale.  
Rotate the potentiometer counter-clockwise to 
decrease pattern scale. 
The potentiometer at min. “ – “ is equivalent to a 
distance of 6m - 8m.

 

 

 

FIG. 7 - MW PATTERN 

 

 

 

 

 

 

 

Table 1: 

##

0

1

2

3

4

5

6

7

8

9

10

a

180°

130°

100°

84°

75°

70°

60°

52°

40°

30°

20°

X

0

3

6

9

12

15

18

21

24

27

28,5

Y

10,5

6,09

7,15

6,98

8,01

10,5

10,39 10,24

8,73

7,23

5,03

X,Y are corresponds (m) of pattern points 
when H=30m 

19

 

 

20

 

 

21

 

LENSES-INTERCHANGEABLE HARD 
TYPE SPHERICAL LENSES PATTERNS 

COVERAGE       WIDE       LONG RANGE   ANIMAL       CURTAIN 
                          ANGLE        CURTAIN        ALLEY,                                 
                     18m x 18m       30m x 2m       18m x 18m    15m x 1m 
                     (60ft x 60ft)   (100ft x 6.3ft)   (60ft x 60ft)   (50ft x .3ft) 
                           +10%             +10% 
TOTAL 
ZONES                  52*                    12                    18               22 

18 long range, 16 intermediate, 10 short range, 

   

6 nearest range, 2 creep zones.    

REPLACING THE LENS

 

1.  Remove the front cover by inserting a flat 

screwdriver in the appropriate slot. 

2.  Using a small flat screwdriver, press on left or 

right side of the installed lens, which will then pop 
out, from its side right and left holding pins. 

3.  Select the desired lens and hold it while making 

sure its upper holding pin is pointed upwards. 

4.  Snap the lens to its place by pressing again 

from outside of the front cover until a click is 
heard, confirming the new lens is tightly inserted.  
5.  Replace front cover. 

 

 

FIG. 8 - REPLACING THE LENS 

 

 

TECHNICAL SPECIFICATIONS 

Detection Method 

Dual element PIR & microwave pulse 

 

Doppler 

Power Input 

8.2  to 16 Vdc 

Current Draw 

Active :    25.5 mA 

 

Standby:  16.5 mA 

Temperature 

 

Compensation 

YES 

Alarm Period 

2 +/- 1  sec 

Alarm Output 

N.C 28Vdc 0.1 A with 10 Ohm series        

 

protection resistors 

Tamper Switch 

  N.C 28Vdc 0.1A with 10 Ohm series 

 

protection resistor - open when cover 

 

is removed 

Warm Up Period  

1 min 

LED Indicator 

Yellow LED is blinking during warm up 

 

period and self testing,  

  

Red LED is ON during alarm 

   

Red LED: UNIT ALARM 

    

Green LED: PIR CHANNEL 

   

 

Yellow LED: MW CHANNEL 

 

22

 

 

23

 

 

24

 

TECHNICAL SPECIFICATIONS (CONT.) 

Operating Temperature 

-20

°

C to +50

°

C(-4

°

F to +122

°

F) 

RFI Protection 

30V/m  10 - 1000MHz 

EMI Protection  

50,000V   of electrical interference 

 

 

from lightning or power through 

Visible Light Protection 

stable against halogen light 2.4 m  

 

 

(8ft )or reflected light 

MW center frequency            2.45 GHz       
MW output power 

min + 5 dBm IERP 

MW harmonic emission   

-20 dBm 

Dimensions 

137mm x 70mm x 53mm 

  

(5.3” x 2.8” x 2.1”) 

Weight    

 

130 gr. (4.,6  oz) 

               

CROW

 reserves the rights to change 

specifications without prior notice 

 

CROW ELECTRONIC ENGINEERING LTD. ("Crow") - WARRANTY POLICY CERTIFICATE 

This Warranty Certificate is given in favor of the purchaser (hereunder the "

Purchaser

") purchasing the 

products directly from Crow or from its authorized distributor. 
Crow warrants these products to be free from defects in materials and workmanship under normal use and 
service for a period of 24 months from the last day of the week and year whose numbers are printed on the 
printed circuit board inside these products (hereunder the "

Warranty Period

").

 

Subject to the provisions of this Warranty Certificate, during the Warranty Period, Crow undertakes, at its sole 
discretion and subject to Crow's procedures, as such procedures are form time to time, to repair or replace, free 
of charge for materials and/or labor, products proved to be defective in materials or workmanship under normal 
use and service. Repaired products shall be warranted for the remainder of the original Warranty Period. 
All transportation costs and in-transit risk of loss or damage related, directly or indirectly, to products returned to 
Crow for repair or replacement shall be borne solely by the Purchaser.  
Crow's warranty under this Warranty Certificate does not cover products that is defective (or shall become 
defective) due to: (a) alteration of the products (or any part thereof) by anyone other than Crow; (b) accident, 
abuse, negligence, or improper maintenance; (c) failure caused by a product which Crow did not provide; (d) 
failure caused by software or hardware which Crow did not provide; (e) use or storage other than in accordance 
with Crow’s specified operating and storage instructions. 
There are no warranties, expressed or implied, of merchantability or fitness of the products for a particular 
purpose or otherwise, which extend beyond the description on the face hereof.  
This limited Warranty Certificate is the Purchaser's sole and exclusive remedy against Crow and Crow's sole 
and exclusive liability toward the Purchaser in connection with the products, including without limitation - for 
defects or malfunctions of the products. This Warranty Certificate replaces all other warranties and liabilities, 
whether oral, written, (non-mandatory) statutory, contractual, in tort or otherwise. 
In no case shall Crow be liable to anyone for any consequential or incidental damages (inclusive of loss of 
profit, and whether occasioned by negligence of the Crow or any third party on its behalf) for breach of this or 
any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Crow does not 
represent that these products can not be compromised or circumvented; that these products will prevent any 
person injury or property loss or damage by burglary, robbery, fire or otherwise; or that these products will in all 
cases provide adequate warning or protection.  
Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of 
burglary, fire, robbery or other events occurring without providing an alarm, but it is not insurance or a 
guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result.  
Consequently, Crow shall have no liability for any personal injury; property damage or any other loss based on 
claim that these products failed to give any warning.  
If Crow is held liable, whether directly or indirectly, for any loss or damage with regards to these products, 
regardless of cause or origin, Crow’s maximum liability shall not in any case exceed the purchase price of these 
products, which shall be the complete and exclusive remedy against

 

Crow.

 

 

 

 

CROW ELECTRONIC ENGINEERING LTD.

 

 

 ISRAEL

Crow Electronic Engineering Ltd. 

 

12 Kineret St. Airport City, 70100 

 

PO. Box 293 Ben Gurion Airport 

 

Tel: 972-3-9726000 

 

Fax: 972-3-9726001 

                     

E-mail: 

[email protected]

 

USA

:                 

2160 North Central Road, 

                     

Fort Lee, N.J. 07024 

                     

Tel: 1-800-GET CROW  

                     

or     (201) 944 0005 

                     

Fax: (201) 944 1199 

                     

E-mail: 

[email protected]

 

AUSTRALIA

:    

429 Nepean HWY Brighton East Vic 3187 

                      

Tel:  61-3-9596 7222 

                     

Fax: 61-3-9596 0888 

                     

E-mail: 

[email protected]

    

POLAND:     

VIDICON SP. ZO. O.

 

                     

15 Povazkowska St. 

 

01 – 797 Warsaw  Poland 

                      

Tel:   48 22 562 3000 

                      

Fax:  48 22 562 3030 

                      

E-mail: 

[email protected]

 

LATIN AMERICA: 

CROW LATIN AMERICA  

 

5753 NW 151

ST

.Street 

 

MIAMI LAKES, 

 

FL 33014 – USA 

 

Tel:  +1-305-823-8700 

 

Fax: +1-305-823-8711 

 

E-mail: 

[email protected]

 

ITALY

:        

      DEATRONIC 

 

 

VIA Giulianello 4/14  

 

 

00178 ROMA, ITALY 

          

Tel:  +39-0676-12912 

          

Fax: +39-0676-12601 

          

E-mail: 

[email protected]

 

These instructions supersede all previous issues in circulation prior to June

 

2005.

 

 

           

7121287_D 

H

0

2

1

3

4

5

6

7

8

9

10

  

2.1m

  

Отзывы: