9 Operation 

Note! 

Connect the EDS-2000 to a positive Voltage output of 9.6 -16VDC source. 

Use only a listed power limited source. 

The detector shall be provided with minimum of 4 hours of standby power from either a 

listed compatible control unit or power supply. 

 

 

The detector is automatically operated once connected to power. 

 

The LEDs start flashing one at a time (side to side) for 30 seconds during the warm-up period 

and after that it will turn off. 

 

At this time the detector is ready for operation. 

Содержание EDS-2000

Страница 1: ...1 ELECTRONIC ENGINEERING LTD EDS 2000 Outdoor PIR MW detector INSTALLATION INSTRUCTIONS USER MANUAL P N 7101720 Rev D ...

Страница 2: ...2 ...

Страница 3: ...on 9 6 Detector Installation 10 7 Terminal Block Connections 12 7 1 Wire Size Requirements 12 8 Settings Adjustments 13 8 1 Detection beam direction 13 8 2 Sensitivity and Range Adjustment 13 8 3 Pet immunity setting 14 8 4 Indications setting 15 9 Operation 16 10 Test procedure 17 11 Specifications 18 ...

Страница 4: ...4 ...

Страница 5: ...he effective pattern will be set for every installation environment and protection site The EDS 2000 is designed to protect large areas and can easily be installed on walls in order to provide a solid protection of the area while rejects interferences from birds and small animals due to PET MASK optics 2 Features MW detection based on Doppler concept N O N C relays switched at the same time Height...

Страница 6: ...ing screws supplied In addition there is an option to mount the EDS 2000 by using a mounting arm not supplied with product For details contact Crow The EDS 2000 is combined of two detection elements PIR element MW element The following drawing shows all internal elements MW Doppler antenna Detection LEDS LEDs control jumper Factory setting ON Tamper switch MW control jumper Factory setting ON Sens...

Страница 7: ...7 49ft 4 Detection Pattern The EDS 2000 has a 90 top view PIR and MW detection pattern with over 15m 49 ft detection distance when installed at 2 4m 7 9 ft above the ground surface Standard Lens ...

Страница 8: ... 7 9 ft above the ground surface Curtain Lens Having MW movement detection combined with PIR detection beam the EDS 2000 can differentiate between pets and human bodies and alert accordingly By having both PIR detection beam and MW crossing an object it will be defined as intrusion causing an alarm In case only MW detects motion and PIR does not no alarm will be generated ...

Страница 9: ... angle of more than 10º from perpendicularline Mounting at more than 10º Deviation from horizontal line Facing metal doors Do not install near direct source of heat or air gust Clear all physical obstacles from the detection area e g Plants laundries etc Clear all light reflecting surfaces from the detection area as well as water puddles Avoid installation on the following types of ground Thick ve...

Страница 10: ...tector is to be installed at height of 1 8 to 2 4 meters 5 9 to 7 9 ft 3 Make sure to attach the metal bracket to a leveled straight and firm wall leaving 10cm 4 inches from the top and 10cm 4 inches from both sides for easy installation and maintenance 4 Placing the detector on perpendicular wall is required for guarding a side window opening 5 Open the detector unwinding the bottom screw 6 Relea...

Страница 11: ...0 Attach the sealing sponge pad to the wire opening from the rear side after the wires connection andprior to final product affixing to the mounted bracket 11 Place the detector on the mounting bracket from top side down and then lock the screw at the bottom 12 Select relevant PET immunity level by disassembling PET filter supplied and assembled or using the filter Refer to paragraph 8 3 for more ...

Страница 12: ... installation wall an immediate alarm signal will be sent to the CP Terminal 5 Marked EOL End of line optional terminal for end of line resistors connections Terminals 6 7 8 Marked NC C NO These are the output relay contacts of the detector Connect to a normally closed or normally opened zone in the control unit When an intruder is detected alarm relays N C and N O will switch for 1 8 sec 7 1 Wire...

Страница 13: ... playground football court service road etc Risk Stable environment with some trees boshes flowerpots planters High risk Unstable environment with different types of vegetation and grass and puddles Very high risk Unstable environment with winds and small pets rats mice birds Noisy area Unstable environment with vegetation and water sources like swimming pool lake canal weed as well as small pets ...

Страница 14: ...Noisy area 9 12 o clock L Extremely Noisy area 8 o clock L Note Adjust sensitivity according to environmental conditions 8 3 Pet immunity setting The EDS 2000 has a detachable Pet immunity filter As such the Pet immunity level may vary between 1 36kg 80 lbs with pet immunity filter assembled 2 15kg 33 lbs if no pet immunity filter is used The installer is to select the requested Pet immunity level...

Страница 15: ...ection 2 Yellow LED indicates MW detection 3 Red LED alarm indication logic AND of both MW and PIR The installer has an option to control LEDs operation using the LED control jumper between ON and OFF Detection LEDs LEDs Control jumper Factory setting ON Place the top cover to the base and close it using the bottom screw ...

Страница 16: ...be provided with minimum of 4 hours of standby power from either a listed compatible control unit or power supply The detector is automatically operated once connected to power The LEDs start flashing one at a time side to side for 30 seconds during the warm up period and after that it will turn off At this time the detector is ready for operation ...

Страница 17: ...urned ON Allow 5 sec between each test for the detector to stabilize Upon installation the unit should be thoroughly tested to verify proper operation Walk across the entire area where coverage is desired Should the coverage be incomplete readjust sensitivity or relocate the detector Once coverage is as desired the LEDs may be disabled NOTE Walk Test procedure should be conducted at least once a y...

Страница 18: ... Indicator All LEDs are ON during ALARM RF Immunity 10 V m plus 80 AM from 80 MHz to 2GHz ElectroStatic Immunity 6kV contact 8kV air Transient Immunity 1kV Operation Temp 35ºC 55ºC 31 F 131 F Dimensions 160mm x 70mm x 45mm 6 9 x 2 8 X 1 8 Weight 210gr 0 5 lbs European directives RTTE directive 1999 5 EC EMC directive 89 336 EEC Low Voltage directive 73 23 EEC RoHS directive 2002 95 EC European sta...

Страница 19: ...y other basis of liability whatsoever even if the loss or damage is caused by CROW s own negligence or fault CROW does not represent that this product can not be compromised or circumvented that this product will prevent any person injury or property loss or damage by burglary robbery fire or otherwise or that this product will in all cases provide adequate warning or protection Purchaser understa...

Страница 20: ...com CROW LATIN AMERICA USA INC 7200 NW 19 st Suite 307 Miami FI 33126 USA Tel 305 513 4001 Fax 305 513 4005 rejane crowlatinamerica com www crowlatinamerica com ARROWHEAD ALARM PRODUCTS 344B Rosedale Road Park Farm Industrial Estate Albany Auckland New Zealand Tel 64 9 414 0085 Fax 64 9 414 0088 www aap co nz These instructions supersede all previous issues in circulation prior to May 2020 ...

Отзывы: