![Crow EDS-2000 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/crow/eds-2000/eds-2000_installation-instructions-and-user-manual_2689377013.webp)
13
8 Settings
&
Adjustments
8.1 Detection
beam
direction
The EDS-2000 detection beam direction is fixed. As a result, it is recommended to face the
intrusion area with the detector.
8.2 Sensitivity and Range Adjustment
There are 6 groups of environments for which different setting are required:
Low risk: very stable environment without interference like parking garage, under roof
parking space, playground, football court, service road, etc.
Risk: Stable environment with some trees, boshes, flowerpots, planters.
High risk: Unstable environment with different types of vegetation and grass and
puddles.
Very high risk: Unstable environment with winds and small pets, rats, mice, birds.
Noisy area: Unstable environment with vegetation and water sources like swimming
pool, lake, canal, weed as well as small pets like cats and rabbits.
Extremely Noisy area: Very unstable environment subjected to wind, snow, rain, with
vegetation, water and large pets like dogs.
Sensitivity
Potentiometer
MW intensity
setting