5.2 Switching on the 30 Hz filter
(INP A, INP B)
30 Hz filter off (fmax)
30 Hz filter on
Count input and count
direction input
INP A: Count input
INP B: Count direction
input
Differential input
IINP A: count input adding
INP B: count input sub-
tracting
Totalising
INP A: count input adding
INP B: count input adding
Quadrature input
INP A: count input 0°
INP B: count input 90°
Quadrature input with
pulse doubling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A
will be counted
Quadrature input with
pulse quadrupling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A
and INP B will be count-
ed.
For the frequency
measurement, INP C may
be operated independent-
ly of the counter input
modes.
5.3 Input mode
5.4 Multiplying factor
(counter)
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0“ is not accepted!
5.6 Decimal point
(counter)
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
It can be set from
00.0001 up to 99.9999.
The decimal point is set
to 4 decimal places.
„0“ is not accepted!
5.5 Dividing factor
(counter)
5.7 RESET Mode
(counter)
manual reset via the red
RESET key
no reset (red RESET key
locked)
The filter provides input
damping*
* where bounce occurs, e.g. with contacts
Содержание 87623572
Страница 6: ...6 Raccordement D coupe panneau 22 2 0 3 x 45 0 6 mm Dimensions 24 48 CTR24L...
Страница 12: ...6 10 Dimensions Wiring diagram 24 48 CTR24L...
Страница 18: ...6 10 Dimensioni 24 48 CTR24L...
Страница 24: ...6 10 Dimensiones 24 48 CTR24L...
Страница 30: ...6 Schalttafelausschnitt 22 2 0 3 x 45 0 6 mm Anschlussbelegung 10 Abmessungen 24 48 CTR24L...
Страница 31: ......
Страница 32: ...R 60035 9451 Crouzet Automatismes SAS 2 rue du Docteur Abel BP 59 26902 Valence CEDEX 9 FRANCE www crouzet com...