Crosswater ATOLL SQUARE EXPOSED THERMO SHOWER VALVE SQ600WC Скачать руководство пользователя страница 2

1

INTRODUCTION

Please read these instructions carefully and keep in a safe place for future reference.
General Installation Requirements

The installation must comply with regulations of the Local Water Authority as contained in 

their bylaws. 

All of the taps in this range are single flow (the hot and cold water mix in the 

body) and should therefore be supplied with hot and cold water at balanced pressures,  

both from the tank or both from the mains (via a combination boiler for example). If the taps 

are not supplied at balanced pressures then the mixer will not function correctly

. It is very 

important that all pipe work is flushed thoroughly after installation to avoid damaging the 

ceramic discs.

Minimum/Maximum working pressure

These taps are suitable for high and low pressure installations they are fitted with a ceramic 

disc cartridge which provides a good flow rate with very smooth movement. 

To ensure that 

the mixer works adequately under low pressure, the cold water storage tank should be at 

least 2 metres above the highest installed position. 

The maximum water pressure is 10 bar 

(note: mains cold water is normally supplied at between 2 and 3 bar). 

 

For installations where the mains pressure exceeds 5 bar a pressure reducing valve 

 

should be fitted.

Approvals

All products are manufactured using materials tested and approved under the Water Bylaws 

Scheme and comply with requirements of British Standard 5412: 1996 where applicable.

WARNING

Before installing the new mixer it is essential that you thoroughly flush through the 

supply pipes in order to remove any remaining swarf, solder or other impurities.
Failure to carry out this simple procedure could cause problems or damage to the 

workings of the mixer.

These hints have been prepared for your guidance, you must exercise due care at all times.

We do not accept responsibility for any problems that may occur through incorrect 

installation.

SQ600WC

10

CLEANING

TROUBLE SHOOTING

SYMPTOM

SOLUTION

After installation the shower runs HOT or     

COLD and will not mix.

Hot and cold supplies are plumbed the wrong 
way round.

Shower will not run hot enough when first 

installed.

Maximum temperature needs adjusting, see 

‘temperature setting’.

Cold water tracking through the valve into 
the hot water system.

Check and clean the filters.

V

ery low flow or no flow (gravity).

Check hot and cold feeds (the valve will shut 

down if either the hot or cold supply fails.

CARE OF YOUR SHOWER VALVE & RISER

We recommend cleaning the valve with a soft damp cloth. 

We strongly advise against the use of ALL cleaning products.

SHOWER ROSE & HANDSET

Your shower rose and handset has rub 

clean nozzles for easy cleaning. Rub 

your fingers across the rubber nozzles to 

remove any scale or debris.

If you live in a hard water area you might 

have to repeat this procedure regularly.

Содержание ATOLL SQUARE EXPOSED THERMO SHOWER VALVE SQ600WC

Страница 1: ...RMO SHOWER VALVE INSTALLATION INSTRUCTIONS For any further information please contact Crosswater on Or visit our web site at www crosswater co uk The manufacturer reserves the right to make technical modifications without prior notice ...

Страница 2: ...d using materials tested and approved under the Water Bylaws Scheme and comply with requirements of British Standard 5412 1996 where applicable WARNING Before installing the new mixer it is essential that you thoroughly flush through the supply pipes in order to remove any remaining swarf solder or other impurities Failure to carry out this simple procedure could cause problems or damage to the wor...

Страница 3: ...h the cartridge with clean running water dry and lightly grease the seal THERMOSTATIC CARTRIDGES The concealed thermostatic valve should give trouble free service but in the event of failure servicing is straight forward To remove the thermostatic cartridge Remove the handle cover see temperature setting Pull off the stop ring Using a hexagonal key undo and remove the screw on the underside of the...

Страница 4: ... with the button on top to turn off the flow of water Turn the Temperature control handle to increase decrease the temperature Push down on the Override button and turn the handle towards you to override the set temperature To change the set temperature see section on page 7 Temperature setting OVERRIDE BUTTON TEMPERATURE CONTROL HANDLE FLOW CONTROL TO HANDSET FLOW CONTROL TO SHOWER ROSE SQ600WC 2 ...

Страница 5: ...to run until the cold storage tank and pipes are empty the hot water storage cylinder always remains full Where combination boilers are fitted it is only necessary to turn off the boiler and shut off the incoming mains Fitting isolating valves to the inlet feeds is recommended for ease of maintenance INSTALLATION Remember to turn off the mains water supply before connecting to any existing pipe wor...

Страница 6: ...ver see fig 1 Secure the shower rose to the riser using the fibre washer see fig 2 Remove the riser nut and O ring from the valve and slide onto the riser Push the riser down into the connection outlet on the valve slide down the O ring and tighten the riser nut Slide the riser support to meet the bracket and screw together There are 2 flats on the bracket pillar to aid tightening Insert a fibre washer...