30
Released on 10/31/05 - X800058A
UV Pure Technologies Inc. © 2005
No part of this document may be photocopied, reproduced, transmitted, or translated to another language without the
prior written consent of UV Pure Technologies Inc.
For additional info call 1-888-407-9997 or email
or visit
www.uvpure.com
top fold.
Step 5:
Examine the quartz sleeve both inside and out. If it is clean, no
disassembly is required. Replace the side panel, lamps and covers. Plug in the
unit and operate as normal. If the quartz sleeve is dirty on the outside, proceed to
wipe it down with a clean lint-free cloth and rubbing alcohol to remove the dirt. If
the quartz sleeve is dirty on the inside, proceed with in-place cleaning or
disassembly.
Caution:
The quartz sleeve can break or chip if mishandled. Always handle it
with care and keep it in a safe place if it is removed from the unit. Do not strike
the quartz sleeve with any tool, since even the smallest chip can cause it to
break under pressure.
In-place cleaning
This procedure will clean the quartz without its removal from the unit. This is a
quick and easy procedure that works well in most cases.
Step 1:
Fill a bucket or container with water before shutting off the water supply
since you will need the water later to clean the quartz sleeve (3). A squeeze
bottle is useful for applying water or cleaning solution
to the inside of the quartz
sleeve.
Step 2:
Open the unit and remove the lamps (see Determining the Need for
Cleaning).
Step 3:
Place another bucket under the unit and drain the unit until there is about
1” (3cm) of water left in the quartz sleeve (see Draining the Unit).
Step 4
: Disconnect the
top
hose from the plumbing side (not the unit side but
other end).
Step 5
: Add about 2 oz. (60cc) of cleaning solution to the top hose. The cleaning
solution can be a citric acid, vinegar or other non-hazardous solutions.
Any
solution used should be thoroughly rinsed out afterwards.
Fill the rest of the
quartz with water.
Step 6
: Let the cleaning solution remain in the quartz for at least 10-20 minutes.
Step 7:
Manually
turning the wiper may greatly assist the cleaning process. To
do this, remove the motor assembly (see Step 7 in the Disassembling the Unit
section) and turn the wiper shaft with a flat-bladed screwdriver (counterclockwise
while looking at the shaft).
Step 8:
Drain the unit and inspect the quartz sleeve. If clean, flush the unit with