Silencing Nuisance Alarms

Crossfire Features and Functions

Testing the Bed Shaker 520

Every Crossfire alarm or product should be tested weekly to ensure proper operation.

To test the Bed Shaker 520 or any Crossfire alarm, 

press and release the button on the front face of 

the unit.

The unit will beep three times, the FIRE light will 

flash, and the shaker will vibrate.
All four icons will strobe to indicate a successful 

test.
The Bed Shaker will then send out a network test

command and all other alarms on the network will 

perform the  same self test.
If the unit fails, the horn will emit a steady honk.  

Check the batteries.  If the unit still fails, contact the 

manufacturer.

The Crossfire family of products is equipped with a silence feature that will 

decrease the sensitivity of an alarm and silence nuisance alarms.

If in the course of normal activity, cooking smoke, 

steam or other gases cause the alarm to activate, 

the alarm can be silenced for ten minutes by 

pressing the button on the front face of the 

alarm.

If the quantity of smoke is too great, the 

alarm will not silence until the air has 

cleared sufficiently.

Due to its convenient placement in the home, 

the Bed Shaker 520 can be easily used to silence 

alarm warnings.  Because the Bed Shaker is not an 

alarm itself, only remotely activated alarms will 

be silenced.  The initiating alarm must be silenced 

directly.

Creating Your Radio Network

The Crossfire product line communicates on its own private radio network.  This 

network is created simply by powering up new units one at a time.

General Note:

  The radio network is limited to 18 

total units.  Only 12 of these units may be smoke 

alarms, the remaining units can be CO and heat 

alarms.

The blue RADIO light will begin to flash slowly.

While the blue RADIO light is flashing, additional 

Crossfire alarms and products may be added to 

your network.
At any time during this period, the Bed Shaker 

520 may be added.

The Bed Shaker has been added 

to your network!

Activate your first alarm by moving the slide 

switch located on the back side of the alarm in 

the direction indicated by the arrow.  

One minute after activating the last alarm, the  

RADIO light will stop flashing on the original 

alarm, and it will join the network.  The network 

is now closed.

Continue activating each new unit, one alarm at 

a time, until all alarms have been added to the 

network.  This should include smoke, CO and heat 

alarms as well.

General Note:

  

It is easiest to first create the 

radio network while all alarms are located  

together, such as on a table.

The blue RADIO light will flash briefly, then the 

alarm will chirp twice and all four of the lighted 

icons will strobe on in succession.

Note:

 This switch is connected to a lock-out 

mechanism that will prevent installation on the 

bracket until activated.

The slide switch will lock into place when fully 

positioned.

Simply install the (3) supplied Duracell CR123 

batteries as indicated on the underside of the 

Speaker unit.

BedShaker Manual, Exigent Canada 2-17-16.indd   8-9

2/17/2016   5:49:08 PM

Содержание Bed Shaker 520

Страница 1: ...z Horn and Bed Shaker Physically Shakes the Bed While Alarming Low Frequency Bed Level Alarm Sound Easy to Reach Silence Feature Proprietary Wireless Connectivity MADE IN THE U S A Models CFBS520 CFBS...

Страница 2: ...r Kit page 4 Recommended Locations for Your BedShaker 520 page 5 National Fire Protection Association Standards page 5 Complete Home Fire Protection page 6 Acceptable Radio Network Alarm Spacing page...

Страница 3: ...be installed as follows 1 In all sleeping rooms and guest rooms 2 Outside each separate dwelling unit sleeping area within 21 ft 6 4 m of any door to a sleeping room with the distance measured along a...

Страница 4: ...tor Light Green On the CFBS520 the POWER icon will briefly flash every 56 seconds when the batteries are installed RADIO will flash once per second to indicate the radio network is open to accept addi...

Страница 5: ...reating Your Radio Network The Crossfire product line communicates on its own private radio network This network is created simply by powering up new units one at a time General Note The radio network...

Страница 6: ...fully repeat these steps If the unit being added was previously used follow the steps on Page 14 to erase its network data Then re open this alarm s radio function using steps 1 2 in this section Pres...

Страница 7: ...he Bed Shaker unit in water or any other liquid as this could permanently damage the unit FCC Compliance Statement and IC Notice This device complies with part 15 of the FCC Rules Per RSS Gen Section...

Страница 8: ...d property A smoke alarm is not a substitute for an adequate homeowner s fire insurance or life insurance policy Smoke alarms will not work without a source of power The alarm will not operate and the...

Страница 9: ...Limited Warranty gives you specific legal rights and you may also have other rights which vary from state to state This is your copy of the Limited Warranty on your Crossfire BedShaker 520 Please ret...

Страница 10: ...18 19...

Страница 11: ...20 REV 10 23 15 90 4072 00 Exigent Sensors LLC 11331 Markon Drive Garden Grove CA 92841 USA www crossfirealarms com...

Отзывы: