11. Hold the log with clamping brackets closely in the control lever guards. lower levers to
start the splitting. Releasing either lever stops the motion of the splitting wedge. Releasing
both handles to return the splitting wedge to the upper position.
12. Stack as you work. This will provide a safer work area, by keeping it uncluttered, and avoid
the danger of tripping, or damaging the power cord.
Accumulated split wood and wood chips can create a hazardous
work environment. Never continue to work in a cluttered work area
which may cause you to slip, trip or fall.
11
REPLACING HYDRAULIC OIL
The hydraulic system is a closed system with oil tank, oil pump and control valve. Check oil
level regularly with dipstick. Low oil levels can damage the oil pump. Oil Level should measure
approx. 1 ~ 2 cm lower than the upper surface of the oil tank.
The oil should be completely changed once a year.
Make sure moving parts stops and the log splitter is unplugged.
Make sure that no dirt or debris finds its way into the oil tank
Collect used oil and responsibly recycle.
Following an oil change, activate the log splitter a few times without actually splitting
Following hydraulic oils or equivalent are recommend for the log splitter’s hydraulic
transmission system:
SHELL Tellus 22
MOBIL DTE 11
ARAL Vitam GF 22
BP Energol HLP-HM 22
l
l
l
l