![crosscontrol CCpilot X900 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/crosscontrol/ccpilot-x900/ccpilot-x900_technical-manual_2688912014.webp)
CCpilot X900
Revision 1.1
Technical Manual
2020-02-03
www.CrossControl.com
14
Bit-rate configurable up to 5 Mbps.
Supported bit-rates include (but are not limited to):
10 kbps, 20 kbps, 50 kbps, 100 kbps, 125 kbps, 250 kbps,
500 kbps, 800 kbps, 1 Mbps, FD 250/500 kbps, FD
250/1000 kbps, FD 250/2000 kbps, FD 250/4000 kbps, FD
500/1000 kbps, FD 500/2000 kbps, FD 500/4000 kbps
Power
12 or 24 VDC nominal voltage. Voltage range 10-34 VDC.
CPU and communication operational down to 6,0 VDC.
Power consumption :
Shutdown : <100mW (typical 70mW @ 24 volt)
Suspend : < 1.5W ( typical 700mW @ 24 Volt)
OS
CC Linux
Software
CCAux API, CCSettingsConsole. Refer to the
CC Linux -
Software Guide
and P
rogrammer’s guide
for details
7.2.
Environmental Tolerance
Environmental Test
Standard
Dry Heat
IEC 60068-2-2
Operating: +70°C, 24h
Storage: +85°C, 24h
Damp Heat
IEC 60068-2-30
Operation: +25°C / +55°C
>95% RH 6*24h
Cold
IEC 60068-2-1
Operating: -25°C, 24h
Storage: -40°C, 24h
Temperature tolerances
IEC 60068-2-14
-25°C to +70°C, 5C/min
3hr hold time, 20 cycles
Vibration
IEC 60068-2-64
IEC 60068-2-6
0.03g²/Hz 5-199Hz
0.02g²/Hz 20-399Hz
0.01g²/Hz 400-599Hz
0.005g²/Hz 600-1000Hz
3x 1h
+/- 7.5mm 5-11.5Hz
4g 11.5-1000Hz
1 oct/min
3 directions, 10 double sweeps/dir.
Shock
IEC 60068-2-27
30 g / 6ms 3x ±3 s 18 shocks
EMC Electrical Transient
ISO 7637-2
Pulse 1: -450V
2a: +37V
2b: +20V
3a: -150V
3b: +150V
4: -12V
5: +123V
EMC Immunity, ESD
EN 61000-4-2
8 kV air, 6 kV contact
EMC Immunity, RF
ISO 11452-2
ISO 11452-4
RF electromagnetic field
200-1000MHz 30V/m
1000-2000MHz 30V/m
Bulk Current Injection
20-200MHz 60mA
EMC Emission
ISO 14982
Radiated Nar.b. Bro.b.
MHz dBµV/m dBµV/m