CXM543 User’s Manual
Doc.# 6001-0015 Rev 1.2
Page 12
f#
where, # is a single digit integer between 0 (slow) and 9 (fast). Different
filter values and corresponding data rates, resolution and frequency are
provided in Appendix B. When the CXM543 is set to the slowest rate (f0),
data is transmitted at a rate of about 1 sample/sec when the pacing value is
0000. If slower rates are desired, the user can set the pacing value. This
ranges from 0000 (fast) to FFFF (slow). The pacing value is set by issuing
a command:
P = ####
The user can set the baud rate of the CXM543 to the standard valu es from
300 to 76800 baud. The baud rate command is of the form:
B = XXXX <CR><LF>
A complete list of the CXM543 commands can be found in Appendix A.
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]