background image

 FP3000 RAID 

USER'S

 

MANUAL

                                           

 

9

   

CROSS T.E.C  

www.crossups.com

 

 

 

 

3.

 

DELIVERY

 

&

 

INSTALLATION

       

     

                                                                         

     

3.1.

 

Delivery 

 

           

3.1.1.

 

Advice 

               

When

 

delivering

 

the

 

UPS,

 

the

 

weight

 

lifter

 

of

 

more

 

capacity

 

than

 

the

 

UPS's

 

weight

 

is

 

necessary

 

and

 

it

 

should

   

be

 

applied

   

to

 

the

 

bottom

 

support

 

of

 

UPS

 

or

 

the

 

bottom

 

part

 

of

 

the

 

container.

 

Also,

 

the

 

equipment

 

should

 

not

 

be

 

neither

 

shaken

 

nor

 

vibrated.

   

If

 

forced

 

by

 

nature,

 

avoid

 

the

 

inclination

 

of

 

the

 

equipment

 

more

 

than

 

15  

 

from

 

the

 

horizon. 

 

                                                                                                                                                               

3.1.2.

 

Shipment

 

inspection 

                       

-

 

Inspect

 

the

 

delivered

 

equipment

 

in

 

detail

 

for

 

any

 

missing

 

part

 

or

 

any

 

visible

 

damage.

 

If

 

found

 

any,

 

notify

 

CROSS T.E.Co.

 

immediately.

   

 

-

 

Never

 

apply

 

any

 

sharp

 

edged

 

material

 

or

 

tool

 

to

 

the

 

equipment. 

                       

-

 

Avoid

 

any

 

form

 

of

 

physical

 

shock

 

to

 

the

 

equipment.It

 

may

 

cause

 

the

       

malfunction

 

of

 

the

 

system. 

 

           

3.1.3.

 

Storage

 

Before

 

Installation 

               

Before

   

installation,

 

the

   

UPS

 

needs

 

to

 

be

 

stored

 

in

 

a

 

protected

 

place

 

from

 

humidity,

 

dust

 

and

 

other

 

damaging

 

factors

 

to

 

the

 

system

 

performance. 

 

     

3.2.

 

INSTALLATION 

 

           

3.2.1.

 

Condition

 

for

 

installation 

                                     

-

 

Ambient

 

Temperature

 

:

   

0  

 

C

   

-

   

40  

 

-

 

Relative

 

Humidity

     

:

   

Below

 

95%

 

Non-Condensing 

-

 

Operating

 

Altitude

   

:

   

Up

 

to

 

1000m

 

above

 

sea

 

level 

             

 

Note

:

 

This

 

equipment

 

is

 

designed

 

for

 

indoor

 

usage.

   

Avoid

 

installation

 

where

 

   

exposed

 

to

 

rain,

 

wind,

 

direct

 

sunlight,

 

heat,

 

and

 

other

 

damaging

 

factor. 

 

 

 

 

Содержание FP3000

Страница 1: ...FP3000 RAID USER S MANUAL 1 CROSS T E C www crossups com USER S MANUAL Frontier power 3000 UNINTERRUPTIBLE POWER SYSTEM CROSS T E C Co Ltd...

Страница 2: ...ery 3 2 Installation 4 OPERATION PROCEDURE 4 1 Preoperational Requirement 4 2 Preparations 4 3 Operational Procedure 4 4 Ending Operation Procedure 4 5 Emergency Operation 5 MAINTENANCE AND SERVICES 5...

Страница 3: ...onfident and widely known representative product The F3000 RAID Uninterruptible Power System of CROSS TEC is a truly advanced 3 phase on line sine wave UPS which Utilizes new power electronic technolo...

Страница 4: ...sipation board and many other components It will convert input AC power to DC power supply the inverter and simultaneously charge the battery with the best condition possible Also the filtering circui...

Страница 5: ...he moment of detection of any abnormal operation in inverter or over load condition the static switch will simultaneously transfer the power supply to bypass feed commercial power not to interrupt the...

Страница 6: ...quency measurement for each phase 2 Operating condition Rectifier in operation RECT ON Rectifier out of operation RECT OFF Battery equalize charging EQU Battery float charging FLO Inverter in operatio...

Страница 7: ...the battery stops to feed and starts to recharge At the same time the commercial power passes through the normal routine 2 3 4 Internal Failure Over load The output voltage and frequency of inverter...

Страница 8: ...HASE 3 4 W RATED VOLTAGE 380V VOLTAGE STABILITY Within 2 RATED FREQUENCY 60 Hz 0 5 Hz VOLTAGE REGULATION Within 5 RESPONSE TIME Less Than 20mS VOLTAGE ADJUSTMENT Over 5 WAVEFORM DISTORTION Less than T...

Страница 9: ...issing part or any visible damage If found any notify CROSS T E Co immediately Never apply any sharp edged material or tool to the equipment Avoid any form of physical shock to the equipment It may ca...

Страница 10: ...t terminal battery cables need to be connected as well with enough care and concern about the positive and the negative cables Note All the connections are to be made FIRM 4 OPERATION PROCEDURE 4 1 Pr...

Страница 11: ...ON 4 3 2 Turn the battery circuit breaker CB2 ON According to the amount of charging current detection FLO LED or EQU LED will light ON 4 3 3 PRESS ON button and ENABLE button simultaneously for the I...

Страница 12: ...switch together to halt the INVERTER operation and to transfer to bypass mode 4 4 3 Turn OFF the battery circuit breaker CB2 4 4 4 Turn OFF the bypass circuit breaker CB4 4 4 5 Turn OFF the input cir...

Страница 13: ...ational range 5 1 3 Ambient surrounding condition out of operational range 5 1 4 Misuse 5 1 5 Component failure 5 1 6 etc 5 2 Handling The static UPS shall be treated and used as a delicate and sensit...

Страница 14: ...urement F To check the frequency measurement A To select the power condition of phase R B To select the power condition of phase S C To select the power condition of phase T ON To start the INVERTER o...

Страница 15: ...intenance is required It is advisible to record the operational behavior in routine bases for smooth operation and easy service if necessary CATEGORY DESCRIPTION REMARK AC INPUT LED BYPASS INPUT LED I...

Страница 16: ...N REMARK ANY DAMAGE ALARMING CONDITION LED INDICATIONS CIRCUIT BREAKERS STATUS LOAD CONDITION REPLACEMENT OTHER STATUS INPUT LINE INVERTER ON BYPASS ON FAULT BUZZER CONDITION SOLUTION ON ON Normal ON...

Страница 17: ...ON Button 2 If no change call for service FAULT LED is ON Alarm sounds continuously 2 INPUT LINE LED is OFF 1 Possibly battery cut off 2 If the power recovers PRESS OFF RESET Button 3 If no change ca...

Страница 18: ...l abuse improper installation unauthorized service or modification If it becomes necessary to send a defecting unit to CROSS T E Co the product shall be shipped in its original package or with adequat...

Отзывы: