Cross FP3000 Скачать руководство пользователя страница 5

 FP3000 RAID 

USER'S

 

MANUAL

                                           

 

5

   

CROSS T.E.C  

www.crossups.com

 

 

 

           

2.2.4.

 

Output

 

Transformer 

 

The

 

primary

 

lead

 

shall

 

be

 

connected

 

to

 

inverter

 

and

 

the

 

secondary

 

to

 

output

 

in

 

this

 

isolation

 

transformer.

   

It

 

is

 

specially

 

designed

 

to

 

contain

 

the

 

reactance

 

and

 

partially

 

serves

 

as

 

output

 

filter. 

Also,

 

it

 

minimizes

 

the

 

current

 

harmonics,

 

and

 

maximizes

 

efficiency.

 

The

 

input

 

and

 

output

 

voltage

 

and

 

frequency

 

are

 

synchronized

 

by

 

phase

 

lock

 

loop

 

oscillator.

   

The

 

synchronized

 

transfer

 

units

 

are

 

placed

 

at

 

the

 

bypass

 

line

 

and

 

at

 

the

 

inverter

 

section. 

 

           

2.2.5.

 

Static

 

Switch 

                                       

This

 

unit

 

operates

 

as

 

an

 

automatic

 

transfer

 

device

 

between

 

inverter

 

and

 

bypass

 

feed.

   

At

 

the

 

moment

 

of

 

detection

 

of

 

any

 

abnormal

 

operation

 

in

   

inverter

 

or

 

over-load

 

condition,

 

the

 

static

 

switch

 

will

 

simultaneously

 

transfer

 

the

 

power

 

supply

 

to

 

bypass

 

feed

 

(commercial

 

power),

 

not

 

to

 

interrupt

 

the

 

load

 

operation.

   

When

 

the

 

inverter

 

operation

 

returns

 

to

 

normal,

   

the

   

static

   

switch

 

will

 

then

 

retransfer

 

supply

 

line

 

to

 

inverter,

 

again

 

without

 

any

 

interruption. 

In

 

order

 

to

 

avoid

 

the

 

possible

 

rush

 

current

 

evolved

 

from

 

the

 

phase

 

difference,

 

this

 

unit

 

is

 

constituted

 

with

 

only

 

semi-conductors.

   

 

           

2.2.6.

 

Control

 

Circuitry 

 

This

 

unit

 

consists

 

of

 

inverter

 

control,

   

alarming

   

circuit,

 

static

 

switch

 

control,

 

and

 

etc.

   

It

 

is

 

designed

 

to

 

operate

 

though

 

the

 

internal

 

unexpected

 

voltage

 

transient

 

intervenes.

   

Its

 

power

 

comes

 

from

 

the

 

battery

 

by

 

DC/DC

 

converter,

 

and

 

thus,

 

power

 

outage

 

or

 

start-up

 

peak

 

current

 

would

 

not

 

affect

 

the

 

control

 

circuitry

 

operation. 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание FP3000

Страница 1: ...FP3000 RAID USER S MANUAL 1 CROSS T E C www crossups com USER S MANUAL Frontier power 3000 UNINTERRUPTIBLE POWER SYSTEM CROSS T E C Co Ltd...

Страница 2: ...ery 3 2 Installation 4 OPERATION PROCEDURE 4 1 Preoperational Requirement 4 2 Preparations 4 3 Operational Procedure 4 4 Ending Operation Procedure 4 5 Emergency Operation 5 MAINTENANCE AND SERVICES 5...

Страница 3: ...onfident and widely known representative product The F3000 RAID Uninterruptible Power System of CROSS TEC is a truly advanced 3 phase on line sine wave UPS which Utilizes new power electronic technolo...

Страница 4: ...sipation board and many other components It will convert input AC power to DC power supply the inverter and simultaneously charge the battery with the best condition possible Also the filtering circui...

Страница 5: ...he moment of detection of any abnormal operation in inverter or over load condition the static switch will simultaneously transfer the power supply to bypass feed commercial power not to interrupt the...

Страница 6: ...quency measurement for each phase 2 Operating condition Rectifier in operation RECT ON Rectifier out of operation RECT OFF Battery equalize charging EQU Battery float charging FLO Inverter in operatio...

Страница 7: ...the battery stops to feed and starts to recharge At the same time the commercial power passes through the normal routine 2 3 4 Internal Failure Over load The output voltage and frequency of inverter...

Страница 8: ...HASE 3 4 W RATED VOLTAGE 380V VOLTAGE STABILITY Within 2 RATED FREQUENCY 60 Hz 0 5 Hz VOLTAGE REGULATION Within 5 RESPONSE TIME Less Than 20mS VOLTAGE ADJUSTMENT Over 5 WAVEFORM DISTORTION Less than T...

Страница 9: ...issing part or any visible damage If found any notify CROSS T E Co immediately Never apply any sharp edged material or tool to the equipment Avoid any form of physical shock to the equipment It may ca...

Страница 10: ...t terminal battery cables need to be connected as well with enough care and concern about the positive and the negative cables Note All the connections are to be made FIRM 4 OPERATION PROCEDURE 4 1 Pr...

Страница 11: ...ON 4 3 2 Turn the battery circuit breaker CB2 ON According to the amount of charging current detection FLO LED or EQU LED will light ON 4 3 3 PRESS ON button and ENABLE button simultaneously for the I...

Страница 12: ...switch together to halt the INVERTER operation and to transfer to bypass mode 4 4 3 Turn OFF the battery circuit breaker CB2 4 4 4 Turn OFF the bypass circuit breaker CB4 4 4 5 Turn OFF the input cir...

Страница 13: ...ational range 5 1 3 Ambient surrounding condition out of operational range 5 1 4 Misuse 5 1 5 Component failure 5 1 6 etc 5 2 Handling The static UPS shall be treated and used as a delicate and sensit...

Страница 14: ...urement F To check the frequency measurement A To select the power condition of phase R B To select the power condition of phase S C To select the power condition of phase T ON To start the INVERTER o...

Страница 15: ...intenance is required It is advisible to record the operational behavior in routine bases for smooth operation and easy service if necessary CATEGORY DESCRIPTION REMARK AC INPUT LED BYPASS INPUT LED I...

Страница 16: ...N REMARK ANY DAMAGE ALARMING CONDITION LED INDICATIONS CIRCUIT BREAKERS STATUS LOAD CONDITION REPLACEMENT OTHER STATUS INPUT LINE INVERTER ON BYPASS ON FAULT BUZZER CONDITION SOLUTION ON ON Normal ON...

Страница 17: ...ON Button 2 If no change call for service FAULT LED is ON Alarm sounds continuously 2 INPUT LINE LED is OFF 1 Possibly battery cut off 2 If the power recovers PRESS OFF RESET Button 3 If no change ca...

Страница 18: ...l abuse improper installation unauthorized service or modification If it becomes necessary to send a defecting unit to CROSS T E Co the product shall be shipped in its original package or with adequat...

Отзывы: