B) Status Requests
Table 1.1 lists the status requests for the 3117-3338#-720 and briefly describes them.
*
PLEASE NOTE: The two character aa (00-31) prefix in the table below
should be included ONLY when RS-485 is selected.
Table 1.1 3117-3338#-720 Status Requests
Table 1.1 3117-3338#-720 Status Requests
Table 1.1 3117-3338#-720 Status Requests
Command
Syntax*
Description
Status
{aaS1}
Returns {aaS1bbbcccdefg} where:
• bbb = Upconverter gain (000 to 200, 0 to 20.0 dB)
• ccc = Downconverter gain (000 to 200, 0 to 20.0 dB)
• d = Downconverter alarm (0 = alarm off; 1 = alarm on)
• e = Upconverter alarm (0 = alarm off; 1 = alarm on)
• f = Summary alarm (0 = alarm off; 1 = alarm on)
• g = Upconverter mute status (1 = muted)
10 MHz reference mode/status
{aaS2}
Returns {aaS2bc} where:
• b = 0 if internal reference mode is selected
• b = 1 if external reference mode is selected
• b = 2 if auto reference mode is selected
• c = 0 if internal 10 MHz is active
• c = 1 if external 10 MHz is active
IP Address (W8, W18, W28 only)
{aaSi}
Returns {aaSixxx.xxx.xxx.xxx} where:
• x...x is the IP address
Subnet mask(W8,W18,W28 only)
{aaSs}
Returns {aaSsxxx.xxx.xxx.xxx} where:
• x...x is the subnet mask
Unit ID
{aaSU}
Returns {aaSUx...x} where:
• x...x is the unit ID character string (max. 16 characters)
Product Info
{aaSV}
Returns {aaSV2017-xxxx ver y.yy} where:
2017-xxxx is the model with options; yyy is the firmware Rev.
3117-3338#-720 Manual, Rev. 0