2.2
Rear Panel Input/Output Signals -
Figure 2.1 shows the input and output connectors on the rear panel.
1
5
2
3
4
6
7
8
9
AC
GND
J8
J2
EXT 10MHZ
RF OUT
INPUT
10MHZ REF
OUTPUT
INT
EXT
AUTO
S1
J1
RF IN
J101
J11
ALARM
J1 - RF IN (Option SN)
SMA (female) 50
Ω
, -20 to 0 dBm.
See Table 2.2 for other connector
options.
AC INPUT
100-240 ±10% VAC,
47-63 HZ
Uses 2 amp Slow Blo,
5mm fuse
S1 - 10MHZ SWITCH
3-position switch. INT selects internal 10MHz ref.
AUTO selects internal 10MHz ref, unless a 0dBm
±3dB 10MHz signal is inserted on J2. EXT selects
external 10MHz ref from J2.
J2 - EXT 10MHZ INPUT
BNC (female) 75
Ω
. Insert external 10MHz
reference here (3 dBm ± 3 dB).
J101 - RF OUT (Option SN)
Type N (female), 50
Ω
.
-20 to -0 dBm.
See Table 2.2 for other
connector options.
J11 - ALARM
DB9 (female) connector.
See Table 2.1.
J8 - 10MHZ REF OUTPUT
BNC (female) 75
Ω
. Outputs currently
selected 10MHz ref signal (3 dBm ±3 dB).
FIGURE 2.1 2116-21#-1014 Rear Panel I/O
ʼ
s (shown with connector option SN)
TABLE 2.1 J11 Pinouts (DB9)
TABLE 2.1 J11 Pinouts (DB9)
Pin
Function
1
Not Used
2
Not Used
3
Not Used
4
Not Used
5
GND
6
Alarm Relay: Common
7
Alarm Relay: Normally Open
8
Not Used
9
Alarm Relay: Normally Closed
TABLE 2.2 Connector Options
TABLE 2.2 Connector Options
TABLE 2.2 Connector Options
Option
RF
L-Band
N
N-Type, 50
Ω
BNC, 75
Ω
NF
N-Type, 50
Ω
F-Type, 75
Ω
NN
N-Type, 50
Ω
N-Type, 50
Ω
S7
SMA, 50
Ω
BNC, 75
Ω
SF
SMA, 50
Ω
F-Type, 75
Ω
SN
SMA, 50
Ω
N-Type, 50
Ω
SS
SMA, 50
Ω
SMA, 50
Ω
2.3
Front Panel Indicators -
The following are the front panel indicators.
DS2 - ALARM LED
Lights RED when
PLL comes out of lock.
DS1 - POWER LED
Lights GREEN when DC voltage is
present from AC power supply.
DS3 - EXT 10MHZ LED
Lights YELLOW when external
10MHz reference is active.
POWER
EXT
10MHZ ALARM
FIGURE 2.2 2116-21#-1014 Front Panel Controls and Indicators
2116-21#-1014 Manual
Page 7