2.2

  

Rear Panel Input/Output Signals  

Figure 2.1 shows the input and output connectors on the rear panel.

AC

GND

J8

J2

EXT 10MHZ

IINPUT

RF INPUT

10MHZ REF

OUTPUT

INT

EXT

AUTO

S1

J101

J11

ALARM

J1 - RF OUTPUT

SMA (female) 50

. 10.70 to 12.0 GHz, 

-40 dBm max output signal. See Table 
2.2 for other connector options.

AC INPUT

 

100-240 ±10% VAC, 
47-63 HZ
Uses 2 amp Slow Blo, 
5mm fuse

S1 - 10MHZ SWITCH

3-position switch. INT selects internal 10MHz ref. 
AUTO selects internal 10MHz ref, unless a 
+3dBm ±3dB 10MHz signal is inserted on J2. 
EXT selects external 10MHz ref. from J2.

J2 - EXT 10MHZ INPUT

BNC (female) 50

/75

. Insert external 

10MHz reference here (+3 dBm ± 3 dB).

J101 - RF INPUT

SMA (female) 50 

. 12.75 to 

14.0 GHz, -10 dBm max input 
signal. See Table 2.2 for other 
connector options.

J11 - ALARM

DB9 (female) connector. 
See Table 2.1. 

J8 - 10MHZ REF OUTPUT

BNC (female) 50

/75

Outputs the currently selected 
10MHz ref signal (+3 dBm ±3 dB).

RF OUTPUT

J1

1

2

3

4

6

7

8

9

FIGURE 2.1     2116-140T120 Rear Panel I/O

ʼ

s

TABLE 2.1 J11 Pinouts (DB9)

TABLE 2.1 J11 Pinouts (DB9)

Pin

Function

1

Not Used

2

Not Used

3

Not Used

4

Not Used

5

GND

6

Alarm Relay: Common

7

Alarm Relay: Normally Open

8

Not Used

9

Alarm Relay: Normally Closed

TABLE  2.2  Connector  Options

TABLE  2.2  Connector  Options

TABLE  2.2  Connector  Options

Option

L-Band

RF

STD

SMA, 50

SMA, 50

NN

N-type, 50

N-type, 50

2.3

  

Front Panel Indicators 

Figure 2.2 shows the front panel indicators.

DS2 - ALARM LED

Lights RED when PLL comes 
out of lock.

DS1 - POWER LED A

Lights GREEN when DC voltage is 
present from AC power supply.

DS3 - EXT 10MHZ LED

Lights YELLOW when external 
10MHz reference is active.

POWER

EXT

10MHZ ALARM

FIGURE 2.2     2116-140T120 Front Panel Controls and Indicators

2116-140T120 Manual, Rev. 0 

 

            Page 6

   

    

8/11/2022

Содержание 2116-140T120

Страница 1: ...reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment...

Страница 2: ...es Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for...

Страница 3: ...ition the internal reference is used unless a 3 dBm 3 dB 10MHz reference signal is connected to the external reference input The 2116 is powered by a 100 240 10 VAC power supply and mounted in a 1 3 4...

Страница 4: ...t the output Frequency Response 2 0 dB over frequency band 0 5 dB 40 MHz BW Frequency Sense Non inverting LO Characteristics LO Frequency 2 05 GHz fixed Frequency Accuracy 0 01 ppm max over temp inter...

Страница 5: ...e 2116 140T120 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 2116 140T120 is assembled 1 PS IN PIN 1 12 VDC PIN 2 5 VDC PIN 3 5 VDC PIN 4 GROUND PIN 5 GROUND P...

Страница 6: ...ARM DB9 female connector See Table 2 1 J8 10MHZ REF OUTPUT BNC female 50 75 Outputs the currently selected 10MHz ref signal 3 dBm 3 dB RF OUTPUT J1 1 5 2 3 4 6 7 8 9 FIGURE 2 1 2116 140T120 Rear Panel...

Страница 7: ...ear panel 3 way switch S1 Figure 2 1 6 If EXT is selected or AUTO is selected and there is a 10MHz 3 dBm signal at J2 check that DS3 yellow Ext 10MHZ is on Figure 2 2 7 Check that a 10MHz 3 dBm 3 dB s...

Страница 8: ...operation of the equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circu...

Страница 9: ...NC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com PRINTED IN USA 2116 140T120 Manual Rev...

Отзывы: