Cross Technologies 2115-275-1845 Скачать руководство пользователя страница 4

1.2   Technical Characteristics

2115-275-1845 Manual, Rev. 0

 

   Page 4

    

        07/20/17

 ±2.0 dB, 27.50 - 28.50 GHz out; ± 0.5 dB, 40 MHz BW

   Frequency Response

 Channel Characteristics

 LO Characteristics

 ± 0.01 ppm maximum over temp internal reference; external reference input

   Frequency Accuracy

 Non-inverting

   Frequency Sense

 < -55 dBC for two carriers each at -10 dBm out

   Intermodulation

 <-50 dBm, 26.5 - 27.5 and 28.5 - 29.5 GHz

   Spurious, Out of Band

 SIGNAL RELATED <-60 dBC in band, -5 dBm out; SIGNAL INDEPENDENT,<-60 dBm

   Spurious, Inband

 3 dBm, ± 3 dB, 75 ohms, External In or Internal Out

   10 MHz Level

 26.155 GHz

   LO Frequency

 > 60 dB, minimum

   Image Rejection

 + 20 ± 1 dB at Fc

   Gain 

 2.92 mm (female), 50

Ω

   RF Out Connector

 Other

 100-24 ±10% VAC, 47-63 Hz, 25 watts maximum

   Power

 19 inch, Standard Chassis 1.75” high X 14.0” deep

   Size

 DB9 - NO or NC Contact Closure on Alarm

   Alarm Connector

 BNC (female), 75

Ω

 Connector; Works for 50

Ω

 or 75

Ω

   10 MHz Connectors

 BNC (female), 50

Ω

, (designated L-Band)

   RF In Connector

           -110

           -90

            -80

           -75

         -70

           1MHz

         100kHz

          10kHz

          1kHz

      100 MHz 

                                  dBC/Hz

   Phase Noise @ F (Hz) >

 Yellow LED, Indicates External 10 MHz Reference Selected

   External 10 MHz

 Controls, Indicators

 Green LED

   Power

 Selects Internal or External 10 MHz (Rear Panel DP3T Switch)

   INT / AUTO / EXT Switch

 Red LED, External Contact Closure

   PLL Alarm

 TABLE 1.1

2115-275-1845 Block Upconverter Specifications*

 -40 to -25 dBm

  Input Level Range

 20 dB maximum gain

  Noise Figure, Maximum

 -15  dBm

  Input  1 dB Compression

 1.345 to 2.345 GHz

  Frequency

 +5 dBm

  Output 1 dB Compression

 -20 to -5 dBm

  Output Level Range

 Output Characteristics (RF) 

 Input Characteristics (designated L-Band)

 27.50 to 28.50 GHz

  Frequency

 50

Ω

 / 14 dB

  Impedance / Return Loss

 50

Ω

 / 14 dB

  Impedance / Return Loss

 Available Options

 50

Ω

 2.92 (RF), 50

Ω

 2.92 mm (L-Band)

   - 29S

 50

Ω

 2.92 (RF), 50

Ω

 N-Type (L-Band)

   - 29N

 50

Ω

 2.92 (RF), 75

Ω

 BNC (L-Band)

   - 297

 

*+0  to +40 degrees C;  Specifications subject to change without notice.                                                                               © 2017 Cross Technologies, Inc.

Содержание 2115-275-1845

Страница 1: ...roduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment mo...

Страница 2: ...gies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable fo...

Страница 3: ...the external reference is used and in the AUTO position the internal reference is used unless a 3 dBm 3 dB 10MHz reference signal is connected to the external reference input It is powered by a 100 2...

Страница 4: ...BNC female 75 Connector Works for 50 or 75 10 MHz Connectors BNC female 50 designated L Band RF In Connector 110 90 80 75 70 1MHz 100kHz 10kHz 1kHz 100 MHz dBC Hz Phase Noise F Hz Yellow LED Indicate...

Страница 5: ...deep chassis A switching 12 24 5 VDC power supply provides power for the assemblies The 2115 275 1845 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 2115 275 18...

Страница 6: ...r options J11 PLL ALARM DB9 female connector See Table 2 1 J8 10MHZ REF OUTPUT BNC female 75 Outputs currently selected 10MHz ref signal 3 dBm 3 dB J11 ALARM 1 5 2 3 4 6 7 8 9 FIGURE 2 1 2115 275 1845...

Страница 7: ...rear panel switch S1 Figure 2 1 6 If EXT is selected or AUTO is selected and there is a 10MHz 3 dBm signal at J2 check that DS3 yellow Ext 10MHZ is on Figure 2 2 7 Check that a 10MHz 3 dBm 3 dB signa...

Страница 8: ...operation of the equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circu...

Страница 9: ...LOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2115 275 1845 Manual Rev 0 Pag...

Отзывы: