C) Commands Table 1.2 lists the commands for the 2083-914A and briefly describes them. After a command
is sent the 2083-914A sends a return “>” indicating the command has been received and executed.
General Command Format - The general command format is {CND...}, where:
{ = start byte
C = 1 character, either C (command) or S (status)
N = 1-digit command or status character
D = 1 character or more of data (depends on command)
} = stop byte
TABLE 1.2 2083-914A Commandds
Comman
ds
Command
Syntax
Description
Set Frequency Translation Mode
{C1x}
where:
• x = 0 for 140 to 95 Mode
• x = 1 for 95 to 140 Mode
Set 140 MHz End Center Frequency {C2xxx} where:
• xxx = 3 characters
• Values: from 110 to 170 (110 to 170 MHz Fc)
Set Attenuation
{C3xx}
where:
• xx = 2 characters
• Range: 00 to 10 (0 to 10 dB, in 1 dB steps)
Mute Output
{CAx}
where x =:
• 0 to mute output
• 1 to Unmute Output
External Reference
{CEx}
where x =:
• 0 for Internal Reference
• 1 for External Reference
Enable Remote
#
Just # sign
Disable Remote
{CR0}
{CR and zero}
2083-914A Manual
Page 7
9/27/10
Содержание 2083-914A
Страница 5: ...2083 914A Manual Page 5 9 27 10...