1.2   Technical Characteristics

TABLE 1.0 2017-03 Up/Downconverter Specifications*

--------UPCONVERTER--------
Input Characteristics (IF)
Impedance/Return Loss

75 

Ω

 /18 dB

Frequency   

70 ± 18 MHZ

Input Level

-40 to -10 dBm

Output Characteristics (RF)
Impedance/Return Loss

75 

Ω

/12 dB

Frequency 

950 to 1525 MHz

Output level

-20 to 0 dBm

Output 1 dB compression

+5 dBm

Channel Characteristics
Gain range (adjustable)

-10 dB to +30 dB

Frequency Sense

Non-inverting

--------UP AND DOWNCONVERTER--------
Channel Characteristics
Frequency Response

±1.5 dB, 950 - 1525 MHz; ± 0.5 dB, 36 MHz BW

Spurious Response

<-50 dBC in band

Group Delay (max.)

0.01 ns/MHz2 parabolic; 0.03 ns/MHz linear; 1 ns ripple

Synthesizer Characteristics
Frequency Accuracy

± 1.0 ppm max. over temp (±0.01 ppm, option -H) internal reference

Frequency Step

1 MHz (125 kHz, option X)

-120

-100

-85

-75

-75

1MHz

100kHz

10kHz

1kHz

100 Hz 

                       dBC/Hz

    Phase Noise @ Freq

 

10 MHz Level (In or Out)

3 dBm ± 3 dB, 75 ohms (option -E)

Controls, Indicators
Frequency Selection

Direct readout LCD; manual or remote selection

Gain Selection

Direct readout LCD; manual or remote selection

Power

Green LED

Down/Up Alarm

Red LED

Up Mute

Yellow LED

Remote

Yellow LED; RS232C, 9600 baud 
(RS485, option -Q, Ethernet M&C Remote Interface, option-W8)

Other 
RF Connectors

Type F (female) (see Table 2.2 for connector options)

IF Connectors

BNC (female) (see Table 2.2 for connector options)

10 MHz Connectors

BNC (female) (option -E)

Alarm/Remote Connector

DB9 (female) - NO or NC contact closure on alarm

Size 

19 inch, 1RU standard chassis 1.75”H X 16.0”D

Power

100-240 ±10%  VAC, 47-63 Hz, 45 watts max.

Options 
-E

External 10 MHz reference input & output w/ RF insertion

-H

High Stability (±0.01ppm) internal reference

-L

LNB Voltage, +24VDC, 0.5 amps

-V

SSPB Voltage, +24VDC, 2.5 amps 

-T

Temperature Sensor

-X

125 kHz frequency step

-Z

Upconverter Attenuator, 0.1 dB

Comm. Interface/Standard RS232
  -Q

RS485 Remote Interface

  -W8

Ethernet; with Web Browser

  -W18

Ethernet; with Web Browser & SNMP

  -W28

Ethernet; with TCP/IP, Telnet

®

Connectors/Impedance

See Table 2.2

*+10˚C to +40˚C; Specifications subject to change without notice.

2017-03 Manual, Rev. N

 

    Page 4   

    

                   03/22/18

--------DOWNCONVERTER--------
Input Characteristics (RF)
Impedance/Return Loss

75 

Ω

 /12 dB

Frequency   

950 to 1525 MHz

Noise Figure (max.)

15 dB @ max. gain

Input Level

-70 to -20 dBm

Input 1 dB compression

-15 dBm @ 0 dB gain

Output Characteristics (IF)
Impedance/Return Loss

75 

Ω

/18 dB

Frequency 

70 ± 18 MHz

Output level/max. linear

-20 dBm/-10 dBm

Output 1 dB compression

-5 dBm

Channel Characteristics
Gain range (adjustable)

0 dB to +50 dB

Image Rejection

> 50 dB, min.

Freq Sense (selectable)

Inverting/Non-inverting

Содержание 2017-03

Страница 1: ...Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Techn...

Страница 2: ...to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies...

Страница 3: ...t and output and Type F female for RF LNB or SSPB 24 VDC and 10 MHz reference can be inserted on the RF lines as added options A high stability 0 01ppm option is also available It is powered by a 100...

Страница 4: ...C Remote Interface option W8 Other RF Connectors Type F female see Table 2 2 for connector options IF Connectors BNC female see Table 2 2 for connector options 10 MHz Connectors BNC female option E Al...

Страница 5: ...Female DB 9 PC Com Port Male DB 9 2015 16 17 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 male J10 Pinouts RS 232C 422...

Страница 6: ...in 10 to 30 4 characters Option Z ee Rx gain 00 to 50 ff Tx input level 10 to 40 10 to 40 dBm L 0 non inverted Receiver L 1 inverted M 0 Receiver synth alarm N 0 Transmitter synth alarm O 0 Summary al...

Страница 7: ...ange 0950 to 1525 MHz Set Transmitter Input Level aaCIxx where xx 2 characters Range 10 to 40 10 to 40 dBm Set Receiver Frequency aaC2xxxx where xxxx 4 characters standard 7 characters Option X Range...

Страница 8: ...equipment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Страница 9: ...by 16 inch deep chassis A switching 12 5 24 VDC power supply provides power for the assemblies The 2017 03 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 2017...

Страница 10: ...e 2 2 J4 IF IN 70 MHz input 10 to 40 dBm in see Table 2 2 SSPB FUSE F2 SSPB FUSE option V 2 5A Fast Blo 1 4 Fuse installing fuse places 24 VDC 2 5 amp max on the RF OUT J5 center pin F1 LNB FUSE optio...

Страница 11: ...Used 9 Alarm Relay Normally Closed Remote Serial Interface Interface DB 9 Male Protocol RS 232C RS 232C 422 485 option Q 9600 baud rate no parity 8 data bits 1 start bit 1 stop bit TABLE 2 2 IF F RF...

Страница 12: ...LED indicates Downconverter alarm DS6 POWER LED Green LED indicates presence of DC power DS1 REMOTE LED Yellow LED indicates remote operation S2 VERT TOGGLE Vertical toggle switch that controls values...

Страница 13: ...he 2017 03 Downconverter Section 1 Connect a 70 dBm to 20 dBm signal to RF In J2 Figure 2 1 2 Connect the IF OUT J1 to the external equipment 3 Connect 100 240 10 VAC 47 63 Hz to AC on the back panel...

Страница 14: ...p slow blow Type T 5 mm X 20 mm FUSE DRAWER SPARE FUSE INPUT 100 240 10 VAC 47 63 Hz 2A MAX FUSE TYPE T 2A GDC 250 VOLT FOR 100 240 V Figure 2 3 Fuse Location and Spare Fuse 2017 03 Manual Rev N Page...

Страница 15: ...n E Menu 11 Downconverter Reference Out option E Menu 12 Set RS 485 mode option Q Menu 13 Set RS 485 address option Q Menu 14 View PCB Temperature option T Menu 15 View LNB and or SSPB Current options...

Страница 16: ...xecute switch 2 Horizontal Switch This switch is mounted so its movement is horizontal and moves the cursor left or right 3 Vertical Switch This switch is mounted so its movement is vertical and has t...

Страница 17: ...AND GAIN IMMEDIATELY BUT DO NOT GET SAVED UNTIL YOU GO TO THE SAVE MENU AND INDICATE YOU WANT TO SAVE THE CHANGES OR you can scroll to R push the Menu Execute switch to get to SAVE SETTINGS YN Selecti...

Страница 18: ...h the cursor can be moved left or right Pressing the Up Down switch down will toggle the display digit selected until you have the desired gain NOTE THE GAIN WILL BE CHANGED AS YOU ADJUST THE NUMBERS...

Страница 19: ...ssing the Up Down switch down will toggle the display digit selected until you have the desired gain NOTE THE GAIN WILL BE CHANGED AS YOU ADJUST THE NUMBERS HOWEVER THE VALUE WILL NOT BE STORED UNTIL...

Страница 20: ...15 View LNB current and SSPB current options L V Save Settings At the end or when R is selected from any of the above menus SAVE SETTINGS Y N SCROLL PUSH BUTTON UP F 1450 SCROLL SCROLL PUSH BUTTON R...

Страница 21: ...S INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2017 03 Manual Rev N...

Отзывы: