1.0 General
1.1 Equipment Description
The 2016-95 Downconverter converts 250 to 950 MHz to 70 ± 18 MHz in 1 MHz steps with low group delay
and flat frequency response. Synthesized local oscillators (LO) provide frequency selection. Multi-function
push button switches select the input frequency, gain, and other parameters. Front panel LEDs provide
indication of DC power, PLL alarm or Remote operation. Gain is adjustable manually (MGC) over a 0 to 50 dB
range. The frequency and gain are remotely selectable. Parameter selection and frequency and gain settings
appear on the LCD display. Connectors are Type F female for the RF, and BNC female for the IF and optional
external 10 MHz reference input and output (option E). Other connector options are available. The 2016-95 is
powered by a 100-240 ±10%VAC power supply, and is contained in a 1 3/4” X 19” X 16” rack mount chassis.
MENU
EXECUTE
MODEL 2016
C
ROSS
T
ECHNOLOGIES INC.
F=750 G=+25.0
REMOTE
ALARM POWER
DOWNCONVERTER
FRONT
AC
GND
J3
J10
J2
RF IN
10 MHZ
AND
MONITOR
EXT REF
CONTROL
J1
IF OUT
INPUT
1
5
2
3
4
6
7
8
9
J18
10 MHZ
EXT REF
OUTPUT
REAR
FIGURE 1.1 Model 2016-95 Front and Rear Panels
70
MHz
OUT
0.25
to
0.95
GHz
IN
CONTROLLER
F=775 G=+25.0
var
atten
EXT
10MHz*
*OPTIONAL
INT
10MHz
Block Diagram
FIGURE 1.2 Model 2016-95 Downconverter Block Diagram
2016-95 Manual, Rev. A
Page 3